Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
4 results
Search Results
Article Citation - WoS: 2Citation - Scopus: 3Determination of Arsenic by Hydride Generation—laser-Induced Breakdown Spectroscopy: Characterization of Interelement Interferences(Taylor and Francis Ltd., 2018) Bölek, Deniz; Ünal Yeşiller, Semira; Yalçın, ŞerifeIn this study, interelement interferences were evaluated for the determination of arsenic in aqueous samples through laser-induced breakdown spectroscopy (LIBS) hyphenated with a hydride generation sample introduction system. Optimum instrumental and chemical parameters were selected and variation in LIBS signal intensity was recorded for As solution in the presence of comparable concentrations of interfering elements. No significant change in the signal intensity of As(I) 228.8 nm line was observed in the presence of alkali/alkali earth metals; however, the presence of hydride-forming elements has shown a noticeable decrease in the line emission strength of arsenic. The least variation in arsenic signal was observed in the presence of Ge, the most volatile of all. However, the signal has decreased to a greater extent in the presence of Sn, Sb, and Pb. The presence of interfering elements on electron temperature and electron number density of arsenic plasma has also been studied. Plasma temperatures calculated using both As and Ar emission lines in the Boltzmann equation were similar, being around 5000 K. The McWhirter criterion for stationary and homogenous plasmas was utilized for the establishment of the local thermodynamic equilibrium under the plasma conditions studied. Applicability of the technique for multielemental analysis of water samples was tested through spiking experiments. Arsenic signal showed 26% decrease in the multielemental mixture solution. LIBS is among a few atomic spectroscopic techniques that facilitate rapid and simultaneous multielemental analysis without extensive sample preparation steps. However, the analytical performance of the technique still requires more serious efforts to compete with other conventional techniques for routine analysis of environmental samples.Article Citation - WoS: 62Citation - Scopus: 64Ultrasonic Nebulization-Sample Introduction System for Quantitative Analysis of Liquid Samples by Laser-Induced Breakdown Spectroscopy(Elsevier Ltd., 2012) Aras, Nadir; Ünal Yeşiller, Semira; Ateş Arıca, Dilek; Yalçın, ŞerifeIn this study, design and optimization studies of a sample introduction system based on ultrasonic nebulization of metal salts in aqueous environment for laser-induced breakdown spectroscopic detection were presented. The system consisted of an ultrasonic nebulizer connected to a tandem heater-condenser- membrane dryer unit that produces sub-micron size aerosols. Results indicate improvements in detection limits for some elements with the use of membrane dryer. Optimization studies were performed by systematical investigation of LIBS emission signal with respect to laser energy, carrier gas flow rate and detector timing parameters. Under optimized conditions, calibration graphs for Na, K, Mg, Ca, Cu, Al, Cr, Cd, Pb and Zn were constructed and detection limits were calculated. The applicability of the ultrasonic nebulization-LIBS system was tested on real water samples. This system establishes LIBS as an effective analytical tool for both qualitative and quantitative determination of metal aerosols in aqueous environments. This technique is sufficiently rapid to provide real-time monitoring of toxic metals.Article Citation - WoS: 23Citation - Scopus: 22Optimization of Chemical and Instrumental Parameters in Hydride Generation Laser-Induced Breakdown Spectrometry for the Determination of Arsenic, Antimony, Lead and Germanium in Aqueous Samples(Elsevier Ltd., 2013) Ünal Yeşiller, Semira; Yalçın, ŞerifeA laser induced breakdown spectrometry hyphenated with on-line continuous flow hydride generation sample introduction system, HG-LIBS, has been used for the determination of arsenic, antimony, lead and germanium in aqueous environments. Optimum chemical and instrumental parameters governing chemical hydride generation, laser plasma formation and detection were investigated for each element under argon and nitrogen atmosphere. Arsenic, antimony and germanium have presented strong enhancement in signal strength under argon atmosphere while lead has shown no sensitivity to ambient gas type. Detection limits of 1.1mgL-1, 1.0mgL-1, 1.3mgL-1 and 0.2mgL-1 were obtained for As, Sb, Pb and Ge, respectively. Up to 77 times enhancement in detection limit of Pb were obtained, compared to the result obtained from the direct analysis of liquids by LIBS. Applicability of the technique to real water samples was tested through spiking experiments and recoveries higher than 80% were obtained. Results demonstrate that, HG-LIBS approach is suitable for quantitative analysis of toxic elements and sufficiently fast for real time continuous monitoring in aqueous environments.Article Citation - WoS: 60Citation - Scopus: 67Removal of Aqueous Rare Earth Elements (rees) Using Nano-Iron Based Materials(Korean Society of Industrial Engineering Chemistry, 2013) Ünal Yeşiller, Semira; Eroğlu, Ahmet Emin; Shahwan, TalalThe uptake of REEs was investigated using nano-zero valent iron (nZVI) and alumina-supported nZVI (Al-nZVI). The results indicated fast uptake, with saturation approached within 10 min of contact between solutions and solids. Upon using nZVI, the uptake of REEs seemed to be quantitative over the studied range of concentration; 1.0–100.0 mg L−1. When Al-nZVI was used, complete removal was achieved within the range of 1.0–10.0 mg L−1. The solids demonstrated stable performance beyond pH of 2.0, up to neutral pH conditions. Fractionation of REEs on Al-nZVI was observed. The REE ions seem to be fixed to oxide and oxyhydroxide surface groups.
