Optimization of Chemical and Instrumental Parameters in Hydride Generation Laser-Induced Breakdown Spectrometry for the Determination of Arsenic, Antimony, Lead and Germanium in Aqueous Samples

Loading...

Date

Authors

Yalçın, Şerife

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

BRONZE

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Top 10%
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

A laser induced breakdown spectrometry hyphenated with on-line continuous flow hydride generation sample introduction system, HG-LIBS, has been used for the determination of arsenic, antimony, lead and germanium in aqueous environments. Optimum chemical and instrumental parameters governing chemical hydride generation, laser plasma formation and detection were investigated for each element under argon and nitrogen atmosphere. Arsenic, antimony and germanium have presented strong enhancement in signal strength under argon atmosphere while lead has shown no sensitivity to ambient gas type. Detection limits of 1.1mgL-1, 1.0mgL-1, 1.3mgL-1 and 0.2mgL-1 were obtained for As, Sb, Pb and Ge, respectively. Up to 77 times enhancement in detection limit of Pb were obtained, compared to the result obtained from the direct analysis of liquids by LIBS. Applicability of the technique to real water samples was tested through spiking experiments and recoveries higher than 80% were obtained. Results demonstrate that, HG-LIBS approach is suitable for quantitative analysis of toxic elements and sufficiently fast for real time continuous monitoring in aqueous environments.

Description

Keywords

Detection limit, Hydride generation, Laser-induced breakdown spectroscopy, Toxic elements, Antimony, Antimony, Germanium, Lasers, Laser-induced breakdown spectroscopy, Borohydrides, Arsenic, Detection limit, Hydride generation, Lead, Limit of Detection, Spectrophotometry, Water Supply, Toxic elements, Gases

Fields of Science

01 natural sciences, 0104 chemical sciences

Citation

Ünal Yeşiller, S., and Yalçın, Ş. (2013). Optimization of chemical and instrumental parameters in hydride generation laser-induced breakdown spectrometry for the determination of arsenic, antimony, lead and germanium in aqueous samples. Analytica Chimica Acta, 770, 7-17. doi:10.1016/j.aca.2013.02.014

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
26

Volume

770

Issue

Start Page

7

End Page

17
PlumX Metrics
Citations

CrossRef : 13

Scopus : 22

PubMed : 2

Captures

Mendeley Readers : 44

SCOPUS™ Citations

22

checked on Apr 27, 2026

Web of Science™ Citations

23

checked on Apr 27, 2026

Page Views

1274

checked on Apr 27, 2026

Downloads

888

checked on Apr 27, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
4.5355162

Sustainable Development Goals

SDG data is not available