Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
2 results
Search Results
Now showing 1 - 2 of 2
Article Citation - WoS: 18Citation - Scopus: 19Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers(American Chemical Society, 2018) Yücel, Müge; Akın, Osman; Çayören, Mehmet; Akduman, İbrahim; Palaniappan, Alagappan; Liedberg, Bo; Hızal, Gürkan; İnci, Fatih; Yıldız, Ümit HakanThis study reports on a hand-held volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multiwalled carbon nanotube (MWCNT) sensing microchannels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits a stable response to interferences of humidity and CO2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing microchannels "P1" (PVDF-MWCNT), "P2" (PS-MWCNT), and "P3" (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing microchannels upon exposure to breath in the concentration ranges between 35 ppb and 3.0 ppm for acetone and 1 ppb and 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.Article Citation - WoS: 42Citation - Scopus: 43Well-Defined Cholesterol Polymers With Ph-Controlled Membrane Switching Activity(American Chemical Society, 2012) Sevimli, Sema; İnci, Fatih; Zareie, Hadi M.; Bulmuş, VolgaCholesterol has been used as an effective component of therapeutic delivery systems because of its ability to cross cellular membranes. Considering this, well-defined copolymers of methacrylic acid and cholesteryl methacrylate, poly(methacrylic acid-co-cholesteryl methacrylate) P(MAA-co-CMA), were generated as potential delivery system components for pH-controlled intracellular delivery of therapeutics. Statistical copolymers with varying cholesterol contents (2, 4, and 8 mol %) were synthesized via reversible addition-fragmentation chain transfer (RAFT) polymerization. Dynamic light scattering (DLS) analysis showed that the hydrodynamic diameters of the copolymers in aqueous solutions ranged from 5 ± 0.3 to 7 ± 0.4 nm for the copolymers having 2 and 4 mol % CMA and 8 ± 1.1 to 13 ± 1.9 nm for the copolymer having 8 mol % CMA with increasing pH (pH 4.5-7.4). Atomic force microscopy (AFM) analysis revealed that the copolymer having 8 mol % CMA formed supramolecular assemblies while the copolymers having 2 and 4 mol % CMA existed as unimers in aqueous solution. The pH-responsive behavior of the copolymers was investigated via UV-visible spectroscopy revealing phase transitions at pH 3.9 for 2 mol % CMA, pH 4.7 for 4 mol % CMA, and pH 5.4 for 8 mol % CMA. Lipid bilayers and liposomes as models for cellular membranes were generated to probe their interactions with the synthesized copolymers. The interactions were determined in a pH-dependent manner (at pH 5.0 and 7.4) using surface plasmon resonance (SPR) spectroscopy and liposome leakage assay. Both the SPR analyses and liposome leakage assays indicated that the copolymer containing 2 mol % CMA displayed the greatest polymer-lipid interactions at pH 5.0, presenting the highest binding ability to the lipid bilayer surfaces, and also demonstrating the highest membrane destabilization activity. CellTiter-Blue assay showed that the copolymers did not affect the cell viability up to 30 μM over a period of 72 h. © 2012 American Chemical Society.
