Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers

Loading...

Date

Journal Title

Journal ISSN

Volume Title

Open Access Color

BRONZE

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

This study reports on a hand-held volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multiwalled carbon nanotube (MWCNT) sensing microchannels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits a stable response to interferences of humidity and CO2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing microchannels "P1" (PVDF-MWCNT), "P2" (PS-MWCNT), and "P3" (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing microchannels upon exposure to breath in the concentration ranges between 35 ppb and 3.0 ppm for acetone and 1 ppb and 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.

Description

Fields of Science

01 natural sciences, 0104 chemical sciences

Citation

Yücel, M., Akın, O., Çayören, M., Akduman, İ., Palaniappan, A., Liedberg, B., Hızal, G., İnci, F., and Yıldız, Ü. H. (2018). Hand-Held volatilome analyzer based on elastically deformable nanofibers. Analytical Chemistry, 90(8), 5122-5129. doi:10.1021/acs.analchem.7b05187

WoS Q

Q1

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
16

Source

Analytical Chemistry

Volume

90

Issue

8

Start Page

5122

End Page

5129
PlumX Metrics
Citations

CrossRef : 9

Scopus : 19

PubMed : 3

Captures

Mendeley Readers : 51

SCOPUS™ Citations

19

checked on Jun 15, 2026

Web of Science™ Citations

18

checked on Jun 15, 2026

Page Views

2005

checked on Jun 15, 2026

Downloads

671

checked on Jun 15, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.09257702

Sustainable Development Goals

INDUSTRY, INNOVATION AND INFRASTRUCTURE9
INDUSTRY, INNOVATION AND INFRASTRUCTURE