Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
9 results
Search Results
Now showing 1 - 9 of 9
Article Citation - WoS: 3Citation - Scopus: 4Comparison of Conventional and Machine Learning Models for Kinetic Modelling of Biomethane Production From Pretreated Tomato Plant Residues(Elsevier, 2025) Fidan, Berrak; Bodur, Fatma-Gamze; Oztep, Gulsh; Gungoren-Madenoglu, Tuelay; Baba, Alper; Kabay, NalanTomato plant residues (Solanum lycopersicum L.) lack sustainable applications as abundant lignocellulosic biomass after harvest. These residues can be utilized as substrates in anaerobic digestion for biomethane production, generating energy and reducing waste. The purpose of this study was to investigate the sustainable utilization of tomato plant residues for biomethane production at varying conditions and to model biological kinetics. The study aimed to evaluate the effects of varying substrate/inoculum ratios, sulfuric acid pretreatment concentrations, and yeast (Saccharomyces cerevisiae) addition on biogas and biomethane yields under mesophilic conditions (37 degrees C). Maximum biogas and biomethane yields in the studied range were obtained when the substrate/inoculum ratio was 3 (g substrate/g inoculum), the sulfuric acid concentration used for residue pretreatment was 2 %v/v, and the substrate/yeast ratio was 10 (g substrate/g yeast). The yeast ratio of 10 increased the cumulative biogas and biomethane production by 96.5 and 128.9%, respectively. Conventional models (Modified Gompertz, Cone, First-order, Logistic) and Machine Learning models (Support Vector Machine and Neural Network) were compared for biological kinetics. Machine Learning models were also observed to give good fitting results similar to conventional models. Results suggest that Machine Learning models (RMSE: 2.5833-12.0500) are reliable methods like conventional kinetic models (RMSE: 2.1796-13.4880) for forecasting biomethane production in anaerobic digestion processes and Machine Learning models can be applied without needing prior understanding of biomethane production kinetics.Article Citation - WoS: 13Citation - Scopus: 14Boron Removal From Geothermal Brine Using Hybrid Reverse Osmosis/Microbial Desalination Cell System(Elsevier, 2023) Jarma, Yakubu A.; Kabay, Nalan; Baba, Alper; Ökten, Hatice Eser; Gören, Ayşegül YağmurAgriculture sector leads worldwide as the most water consuming sector with water demand. Since natural water resources cannot keep up with the demand, a shift from conventional water resources to unconventional ones is needed. While geothermal water was gaining importance for its energy content, small-scale (<10 L/s) energy plants were not required to reinject their spent geothermal brine. As geothermal resources align with agricultural areas in Western Anatolia, discharge of untreated brine might have severe adverse effects on crop yields and soil quality. In this study, we investigated use of spent geothermal brine for irrigation after treatment with Reverse Osmosis/Microbial Desalination Cell (RO/MDC) hybrid process. Treatment efficiencies for B, COD, As, Li, Fe, Cr concentrations and energy production values were determined. Treated water was initially evaluated for irrigation considering three quality categories (I, II, and III) comprised of parameters such as electrical conductivity (EC), total dissolved solids (TDS), and sodium adsorption ratio (SAR), along with sodium, chloride and boron concentrations. Additionally, magnesium adsorption ratio (MAR) and permeability index (PI) were used to evaluate for irrigation suitability. Although B concentrations in MDC-treated permeate (3.29 mg/L) and concentrate (2.99 mg/L) streams were not low enough to meet Quality I criterion (<0.7 mg/L), they can be still utilized in irrigation of moderate-to-high tolerant plants. Furthermore, PI and MAR parameters pointed to suitability for irrigational use. © 2022Article Citation - WoS: 7Citation - Scopus: 11Utilization of Membrane Separation Processes for Reclamation and Reuse of Geothermal Water in Agricultural Irrigation of Tomato Plants-Pilot Membrane Tests and Economic Analysis(Elsevier, 2022) Jarma, Yakubu A.; Karaoğlu, Aslı; Senan, Islam Rashad Ahmed; Meriç, Mehmet Kamil; Kukul, Yasemin Senem; Özçakal, Emrah; Barlas, Neriman Tuba; Çakıcı, Hakan; Baba, Alper; Kabay, NalanThe quality of irrigation water is critical for enhancing agricultural productivity. As a result, this research was carried out with the aim of treating spent geothermal water before it is used for agricultural irrigation. While doing that, cost analysis of the system was taken into consideration as well. The product water was targeted to suit irrigation water standards for tomato plants. Two commercially available pressure driven membranes (NF8040-70 as NF membrane and TM720D-400 as RO membrane) were employed for this task. A constant applied pressure of 15 bar and 60% of water recovery were kept constant during the product water production while mode of operation for the membrane system was continuous. According to Turkish Ministry of Environment and Urbanization irrigation water standards and the results obtained from this study, it was clearly seen that both NF and RO product waters meet the quality I class irrigation water standards with respect total dissolved substances (TDS), electrical conductivity (EC), concentrations of Na+ and Cl− ions. Quality 1 means that the produced water will not cause any environmental effect when employed for irrigation purpose. Nevertheless, the produced water was found not to obey the irrigation standards with respect to sodium adsorption ratio (SAR) and boron concentration (quality III class). Quality III explains that the water will cause soil infiltration problems when employed for irrigation purpose. Since most of the minerals needed for plant growth were rejected by NF and RO membranes, an appropriate mixing ratio of the product water with well water for remineralization was determined. Mixing 50 and 60% of well water with the product waters of NF (50%) and RO (40%) membranes, respectively was found to be the optimum mixing ratios to produce the requested water quality for tomato irrigation. Quality II class irrigation water which can be applied with caution was targeted in terms of SAR as well as boron concentration (2–4 and 4–6 mg/L) while determining the mixing ratios. The cost of the product water was found as 0.76 and 1.56$/m3 for NF and RO processes, respectively.Article Citation - WoS: 3Citation - Scopus: 5Use of Geothermal Fluid for Agricultural Irrigation: Preliminary Studies in Balçova-Narlıdere Geothermal Field (turkey)(2021) Meriç, M. Kamil; Kukul, Yasemin Senem; Özçakal, Emrah; Barlas, N. Tuba; Çakıcı, Hakan; Jarma, Yakubu Abdullahi; Kabay, Nalan; Baba, AlperBalçova-Narlıdere Geothermal Field (BNGF) hosts the largest geothermal district heating system of Turkey and several geothermal wells used for district heating and thermal tourism activities. This study assesses the use of BNGF geothermal fluid for agricultural activities. The spent geothermal brine was treated using nanofiltration and reverse osmosis membranes on a pilot-scale membrane test system. The qualities of the product were evaluated in terms of agricultural irrigation integrated with the implemented innovative wireless sensor network. It is important to use geothermal fluid, which is consists of valuable minerals, for irrigation. But when using geothermal fluid in irrigation, the chemical composition of the water must be carefully monitored to prevent damage to the plants. Nevertheless, the first result shows that the use of geothermal fluid to irrigate is proving to be a promising and economically viable option in BNGF.Article Citation - WoS: 8Citation - Scopus: 11Brine Minimization in Desalination of the Geothermal Reinjection Fluid by Pressure-Driven Membrane Separation Processes(Elsevier, 2022) Jarma, Yakubu A.; Karaoğlu, Aslı; Senan, Islam Rashad Ahmed; Baba, Alper; Kabay, NalanBrine obtained during water treatment by pressure driven membrane processes remains the major drawback. Therefore, it is of paramount important to find a lasting solution in order to minimize its production by both nanofiltration (NF) and reverse osmosis (RO) membranes. In this study, an experimental study with the aim of brine minimization during membrane desalination of the geothermal reinjection fluid using a mini-pilot scale membrane test system having spiral wound NF and RO membranes was conducted. The membranes employed for this task were TR-NF and BW30-RO membranes. First, studies with different brine to feed ratios of 1:4, 1:3, 1:2 and 2:3 represented as NF-F2, NF-F3, NF-F4 and NF-F5, respectively were investigated using TR-NF membrane. A control study with no brine recirculation was conducted as well in order to check the effect of brine recirculation on the membrane performance. Secondly, studies with BW30-RO membrane using same brine to feed ratios as in the case of NF membrane studies were carried out. An applied pressure of 15 bar, initial water recovery of 60% and 4 h of experimental time were employed as operational conditions for both NF and RO membrane studies. Based on the results obtained, it was found that the brine recirculation (with a brine to fresh feed ratio of 2:3) has a significant impact on the permeate flux. The product water can be utilized for the agricultural irrigation purposes. Nevertheless, the boron concentration in the product water was still high for the sensitive crops.Article Citation - WoS: 58Citation - Scopus: 76Utilization of Renewable Energy Sources in Desalination of Geothermal Water for Agriculture(Elsevier, 2021) Tomaszewska, Barbara; Gökçen Akkurt, Gülden; Kaczmarczyk, Michal; Bujakowski, Wieslaw; Keleş, Nazlı; Jarma, Yakubu A.; Baba, Alper; Bryjak, Marek; Kabay, NalanThe agricultural sector, which is highly dependent on water, is urged to build on improved water management practices and explore available options to match supply and demand because of the water scarcity risks and a sustainable and productive agri-food chain. Geothermal water is an energy source used to generate electricity and/or heat. After harnessing its energy, the remaining water can be used as a water source for irrigation following treatment because of its high ionic content. Geothermal fields are mostly located in rural areas where agricultural activities exist. This would be a good match to decrease the transportation cost of irrigation water. The energy demand of the desalination process for agriculture is higher, requiring additional post-treatment processes. Fossil fuels to fulfill the energy requirements are becoming expensive, and greenhouse gas emissions are harmful to the environment. Thus, efforts should be directed towards integrating renewable energy resources into desalination process. This work focuses on presenting a comprehensive review of geothermal water desalination which is powered by renewable energy and provides specific cases from Turkey and Poland. Furthermore, possible new generation renewable energy systems in desalination are introduced, considering their potential application in the desalination of geothermal water for agricultural irrigation.Article Citation - WoS: 58Citation - Scopus: 59Assessment of Different Nanofiltration and Reverse Osmosis Membranes for Simultaneous Removal of Arsenic and Boron From Spent Geothermal Water(Elsevier, 2021) Jarma, Yakubu A.; Karaoğlu, Aslı; Tekin, Özge; Baba, Alper; Ökten, H.Eser; Tomaszewska, Barbara; Kabay, NalanOne of the factors that determine agricultural crops’ yield is the quality of water used during irrigation. In this study, we assessed the usability of spent geothermal water for agricultural irrigation after membrane treatment. Preliminary membrane tests were conducted on a laboratory-scale set up followed by mini-pilot scale tests in a geothermal heating center. In part I, three commercially available membranes (XLE BWRO, NF90, and Osmonics CK- NF) were tested using a cross-flow flat-sheet membrane testing unit (Sepa CF II, GE-Osmonics) under constant applied pressure of 20 bar. In part II, different spiral wound membranes (TR-NE90-NF, TR-BE-BW, and BW30) other than the ones used in laboratory tests were employed for the mini-pilot scale studies in a continuous mode. Water recovery and applied pressure were maintained constant at 60% and 12 bar, respectively. Performances of the membranes were assessed in terms of the permeate flux, boron and arsenic removals. In laboratory tests, the permeate fluxes were measured as 94.3, 87.9, and 64.3 L m?2 h?1 for XLE BWRO, CK-NF and NF90 membranes, respectively. The arsenic removals were found as 99.0%, 87.5% and 83.6% while the boron removals were 56.8%, 54.2%, and 26.1% for XLE BWRO, NF90 and CK-NF membranes, respectively. In field tests, permeate fluxes were 49.9, 26.8 and 24.0 L m?2 h?1 for TR-NE90-NF, BW30-RO and TR-BE-BW membranes, respectively. Boron removals were calculated as 49.9%, 44.1% and 40.7% for TR-BE-BW, TR-NE90-NF and BW30-RO membranes, respectively. Removal efficiencies of arsenic in mini-pilot scale membrane tests were all over 90%. Quality of the permeate water produced was suitable for irrigation in terms of the electrical conductivity (EC) and the total dissolved solids (TDS) for all tested membranes with respect to guidelines set by the Turkish Ministry of Environment and Urbanisation (TMEU). However, XLE BWRO, CK-NF and NF90 membranes failed to meet the required limits for irrigation in terms of boron and arsenic concentrations in the product water. The permeate streams of TR-BE-BW, TR-NE90-NF and BW30-RO membranes complied with the irrigation water standards in terms of EC, TDS and arsenic concentration while boron concentration remained above the allowable limit. © 2020 Elsevier B.V.Article Citation - WoS: 83Citation - Scopus: 90Packed Bed Column Dynamic Study for Boron Removal From Geothermal Brine by a Chelating Fiber and Breakthrough Curve Analysis by Using Mathematical Models(Elsevier Ltd., 2018) Recepoğlu, Yaşar Kemal; Kabay, Nalan; Yılmaz İpek, İdil; Arda, Müşerref; Yüksel, Mithat; Yoshizuka, Kazuharu; Nishihama, SyouheiIn this study, the performance of N-methyl-D-glucamine (NMDG) type functional group attached a novel boron selective chelating fiber adsorbent, Chelest Fiber GRY-HW, was investigated for boron removal from geothermal brine containing 10–11 mg B/L through a packed bed column. The effect of feed flow rate (Space Velocity, SV) on breakthrough capacity of Chelest Fiber GRY-HW was studied using various SV values (15, 20 and 30 h−1). The effect of SV on breakthrough capacity was particularly apparent when SV was decreased from 30 to 15 h−1. Yoon–Nelson, Thomas and Modified Dose Response (MDR) models were applied to the experimental data to estimate the breakthrough curves and model parameters such as rate constants and breakthrough times. The obtained results showed that the breakthrough curves were better described by Modified Dose Response (MDR) model than those described by Yoon-Nelson and Thomas models in each case. Also, the model estimations for adsorption capacity obtained by MDR model agreed well with the experimental results.Article Citation - WoS: 17Citation - Scopus: 19Effect of Operational Conditions on Separation of Lithium From Geothermal Water by ?-Mno2 Using Ion Exchange–membrane Filtration Hybrid Process(Taylor and Francis Ltd., 2018) Recepoğlu, Yaşar Kemal; Kabay, Nalan; Yoshizuka, Kazuharu; Nishihama, Syouhei; Yılmaz İpek, İdil; Arda, Müşerref; Yüksel, MithatA hybrid system coupling ion exchange and ultrafiltration (UF) was employed to separate lithium from lithium-spiked geothermal water. The effect of process parameters such as adsorbent type, adsorbent dosage, permeate flow rate, and replacement speeds of fresh and saturated adsorbents have been evaluated to determine the efficiency of the hybrid system. According to the results obtained using λ-MnO2 derived from spinel-type lithium manganese dioxide, the optimal operating conditions to separate lithium from geothermal water were found with powdery λ-MnO2 with an adsorbent concentration of 1.5 g adsorbent/L solution, replacement rates of fresh and saturated adsorbents of 6.0 mL/min, and a permeate flow rate of 5.0 mL/min. The ion exchange–UF hybrid system providing an advantage to work with very fine particles easily can be considered as a favorable process for the separation of lithium from geothermal water.
