Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
39 results
Search Results
Now showing 1 - 10 of 39
Conference Object Redundancy resolution options for the twin-it-romans robotic hybrid manufacturing system(Springer Science and Business Media B.V., 2025) Gündüz, G.M.; Dede, Mehmet İsmet Can; Kiper, Gökhan; Schmitz, M.; Corves, B.The Twinnig Iztech in Robotics Manufacturing System (TWIN-IT-ROMANS) project funded by EU Horizon -Widera-2023-Access-02-01 aims to develop a hybrid manufacturing system that can perform additive and subtractive manufacturing processes and inline quality control using a robotic system. The system will incorporate a 6-degree-of-freedom robot arm and a positioner with 2-degree-of-freedom, which will operate synchronously. This manipulation system is to be designed for performing different manufacturing operations with different degrees-of-freedom requirements. In order to reveal alternative trajectory planning scenarios for this system, this paper presents an initial review of redundancy resolution approaches for kinematically redundant robotic manipulators. First, the four main approaches for redundancy resolution techniques are introduced. Then main studies on energy minimization and stiffness maximization for kinematically redundant robotic manipulators are reviewed. Similar or new approaches are planned to be generated and implemented for the redundant system for hybrid manufacturing. © The Author(s), under exclusive license to Springer Nature Switzerland AG 2025.Conference Object Citation - Scopus: 3Four-bar function generation using excel solver(Springer, 2023) Söylemez, Eres; Kiper, GökhanThe Chapter presents a simple and efficient way of approximating a function with a four-bar mechanism using four or five design parameters including one or both of the initial crank angles. The method only involves solution of linear set of equations and evaluating determinants, whereas nonlinear equations are numerically solved using a simple program such as Excel. So, the method is easy to explain and can be taught in an undergraduate course along with the wellknown linear three precision point synthesis problem. Precision point synthesis, order synthesis, mixed order synthesis, least squares approximation and extreme point synthesis can all be treated using the same method. The proposed method is illustrated with numerical examples for all mentioned synthesis problems and shown to be quite efficient with very low amount of structural error values.Article Citation - WoS: 10Citation - Scopus: 10Stiffness Modeling of a 2-Dof Over-Constrained Planar Parallel Mechanism(Elsevier, 2023) Görgülü, İbrahimcan; Dede, Mehmet İsmet Can; Kiper, GökhanStiffness model acquisition of over-constrained parallel mechanisms is relatively difficult since they have more than necessary kinematic loops. In this study, a stiffness modeling solution for over-constrained parallel mechanisms is proposed while considering the computational cost efficiency. Three contributions of the paper are: (1) Presenting the stiffness modeling procedure for serially connected closed-loop structures by using the Virtual Joint Method (2) Considering the effect of dynamic auxiliary forces and dynamic external forces on the mobile platform's deflection and achieving a direct solution by using superposition principle (3) A model fitting procedure for modifying the stiffness coefficients to comply with the experimental data. A 2 degrees-of-freedom over-constrained parallel mechanism is investigated as a case study. However, the proposed stiffness model is 6-DoF since compliant deflections occur in any direction. A finite element analysis and an experimental study verify the model's results.Conference Object Citation - Scopus: 3Design and Balancing of a Novel 2r1t Manipulator With Remote Center of Motion(Springer, 2023) Yılmaz, Tuğrul; Kiper, GökhanThe paper presents a novel manipulator design to be used as an endoscope holder for endonasal skull base surgeries. The manipulator should provide two rotational and one translational motions for the endoscope, where it should be able to be oriented about and slide along the tip of the nostril of a patient as a pivot point. First, suitable manipulators with remote center motion are investigated. Manipulators with serial and hybrid kinematic structure and redundant manipulators with a passive joint are examined. A serial manipulator with a circular arc as the second rotation axis is chosen for the detailed design. The novelty of the kinematic structure of the manipulator is that the end-effector heave motion is achieved in a tangential direction to the circular arc. The constructional design and counter-mass balancing solution for the manipulator are presented. The total assembly mass is 11.6 kg for navigating an endoscope of 0.44 kg mass.Conference Object Citation - Scopus: 2Experimental Compliance Matrix Derivation for Enhancing Trajectory Tracking of a 2-Dof High-Accelerated Over-Constrained Mechanism(Springer, 2022) Paksoy, Erkan; Dede, Mehmet İsmet Can; Kiper, GökhanIf the positioning accuracy of the end-effector of a robot has high priority, compliance characteristics of the elements of its mechanism should be considered. Due to the external loading on the robot, the dimensions of the elements change and this leads to positioning errors for the end-effector. In this paper, an experimental test setup and an experimental procedure are described to derive the compliance characteristics of a planar 2-degree-of-freedom mechanism.Article Citation - WoS: 7Citation - Scopus: 7Gravity Compensation of a 2r1t Mechanism With Remote Center of Motion for Minimally Invasive Transnasal Surgery Applications [article](Cambridge University Press, 2023) Aldanmaz, Ataol Behram; Ayit, Orhan; Kiper, Gökhan; Dede, Mehmet İsmet CanThis work addresses the gravity balancing of a 2R1T (2 rotations – 1 translation) mechanism with remote center of motion. A previously developed balancing solution is modified and applied to a prototype and test results are presented. The mechanism is an endoscope holder for minimally invasive transnasal pituitary gland surgery. In this surgery, the endoscope is inserted through a nostril of the patient through a natural path to the pituitary gland. During the surgery, it is vital for the manipulator to be statically balanced so that in case of a motor failure, the patient is protected against any harmful motion of the endoscope. Additionally, static balancing takes the gravitational load from the actuators and hence facilitates the control of the mechanism. The mechanism is a 2URRR-URR type parallel manipulator with three legs. The payload mass is distributed to the legs on the sides. By using counter-masses for two links of each leg, the center of mass of each leg is lumped on the proximal link which simplifies the problem to balancing of a two degree-of-freedom inverted pendulum. The two proximal links with the lumped mass are statically balanced via springs. Dynamic simulations indicate that when the mechanism is statically balanced, generated actuator torques are reduced by 93.5%. Finally, the balancing solution is implemented on the prototype of the manipulator. The tests indicate that the manipulator is statically balanced within its task space when the actuators are disconnected. When the actuators are connected, the torque requirements decrease by about 37.8% with balancing.Article Citation - WoS: 5Citation - Scopus: 5Loop Based Classification of Planar Scissor Linkages(Springer, 2022) Kiper, Gökhan; Korkmaz, Koray; Gür, Şebnem; Yar Uncu, Müjde; Maden, Feray; Akgün, Yenal; Karagöz, CevahirScissor linkages have been used for several applications since ancient Greeks and Romans. In addition to simple scissor linkages with straight rods, linkages with angulated elements have been introduced in the last decades. In the related literature, two methods have been used to design scissor linkages, one of which is based on scissor elements, and the other is based on assembling loops. This study presents a systematic classification of scissor linkages as assemblies of rhombus, kite, dart, parallelogram and anti-parallelogram loops using frieze patterns and long-short diagonal connections. After the loops are replicated along a curve as a pattern, the linkages are obtained by selection of proper common link sections for adjacent loops. The resulting linkages are analyzed for their motions and they are classified as realizing scaling deployable, angular deployable or transformable motion. Some of the linkages obtained are novel. Totally 10 scalable deployable, 1 angular deployable and 8 transformable scissor linkages are listed. Designers in architecture and engineering can use this list of linkages as a library of scissor linkage topologies.Article Citation - WoS: 6Citation - Scopus: 7Human-Robot Interfaces of the Neuroboscope: a Minimally Invasive Endoscopic Pituitary Tumor Surgery Robotic Assistance System(ASME, 2021) Dede, Mehmet İsmet Can; Kiper, Gökhan; Ayav, Tolga; Özdemirel, Barbaros; Tatlıcıoğlu, Enver; Hanalioğlu, Şahin; Işıkay, İlkayEndoscopic endonasal surgery is a commonly practiced minimally invasive neurosurgical operation for the treatment of a wide range of skull base pathologies including pituitary tumors. A common shortcoming of this surgery is the necessity of a third hand when the endoscope has to be handled to allow active use of both hands of the main surgeon. The robot surgery assistant NeuRoboScope system has been developed to take over the endoscope from the main surgeon's hand while providing the surgeon with the necessary means of controlling the location and direction of the endoscope. One of the main novelties of the NeuRoboScope system is its human-robot interface designs which regulate and facilitate the interaction between the surgeon and the robot assistant. The human-robot interaction design of the NeuRoboScope system is investigated in two domains: direct physical interaction (DPI) and master-slave teleoperation (MST). The user study indicating the learning curve and ease of use of the MST is given and this paper is concluded via providing the reader with an outlook of possible new human-robot interfaces for the robot assisted surgery systems.Other Corrigendum To “kinematic Design of a Non-Parasitic 2r1t Parallel Mechanism With Remote Center of Motion To Be Used in Minimally Invasive Surgery Applications” [mechanism and Machine Theory 153 (2020) 104013] (mechanism and Machine Theory (2020) 153, (s0094114x20302342), (10.1016/J.mechmachtheory.2020.104013))(Elsevier, 2021) Yaşır, Abdullah; Kiper, Gökhan; Dede, Mehmet İsmet CanThe authors regret that one of the affiliation information for Gökhan Kiper is wrong. Dr. Kiper is not affiliated to Delft University of Technology. Dr. Kiper is affiliated to İzmir Institute of Technology. The data administrators of Elsevier and the corresponding author would like to apologise for any inconvenience caused. © 2021 International Federation for the Promotion of Mechanism and Machine ScienceArticle Citation - WoS: 31Citation - Scopus: 37Kinematic Design of a Non-Parasitic 2r1t Parallel Mechanism With Remote Center of Motion To Be Used in Minimally Invasive Surgery Applications(Elsevier Ltd., 2020) Yaşır, Abdullah; Kiper, Gökhan; Dede, Mehmet İsmet CanIn minimally invasive surgery applications, the use of robotic manipulators is becoming more and more common to enhance the precision of the operations and post-operative processes. Such operations are often performed through an incision port (a pivot point) on the patient's body. Since the end-effector (the handled surgical tool) move about the pivot point, the manipulator has to move about a remote center of motion. In this study, a 3-degrees-of-freedom parallel mechanism with 2R1T (R: rotation, T: translation) remote center of motion capability is presented for minimally invasive surgery applications. First, its kinematic structure is introduced. Then, its kinematic analysis is carried out by using a simplified kinematic model which consists of three intersecting planes. Then the dimensional design is done for the desired workspace and a simulation test is carried out to verify the kinematic formulations. Finally, the prototype of the final design is presented.
