Civil Engineering / İnşaat Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/13

Browse

Search Results

Now showing 1 - 4 of 4
  • Conference Object
    Citation - Scopus: 2
    A Critical Evaluation of Proxy Measures Used To Quantify Excavation-Induced Damage in Masonry Buildings
    (CRC Press, 2022) Liu, Yiyan; Gülen, Burcu; Açıkgöz, Sinan; Burd, Harvey; Gilson, Ben; İlki, Alper; Dalgıç, Korhan Deniz
    Building response during nearby excavation activities (e.g., tunnelling or deep excavations) is traditionally monitored by conducting displacement measurements. These displacement data are then post-processed to determine proxy measures that are correlated to damage categories. For masonry buildings, commonly-used proxy measures include building deflection ratio, horizontal relative displacement and angular distortion; simple mechanical models and empirical rules are used to define limiting values for these proxy measures to identify and control the level of cracking in buildings during construction. This procedure has a profound influence on mitigation and construction activities, and a critical evaluation of its veracity is needed. To this end, results from a recent experimental campaign on the settlement response of half-scale masonry buildings are examined in this paper. During these tests, detailed optical measurements were conducted, allowing the calculation of absolute displacements across the façade, as well as crack opening displacements at specific locations. These measurements facilitate a direct comparison between the actual observed damage and the damage category that is indicated by the proxy measures. The comparisons highlight the limitations of existing techniques. A discussion is provided on how proxy measure calculations can be improved to deliver more reliable indications of building damage. © 2022 the Author(s).
  • Conference Object
    Citation - Scopus: 3
    Seismic Performance of Cfrp Jacketed Sub-Standard Rc Columns Under High Axial Stress and Shear Demand
    (Springer, 2022) Demir, Merve Nur; Demir, Uğur; Demir, Cem; İlki, Alper
    In the last decades, lessons learnt from the major earthquakes, that occurred in many countries, brought revisions in prevailing seismic design codes. As a consequence of this phenomenon, the current building stock in Turkey is mainly comprised of reinforced concrete (RC) buildings which were designed according to different seismic design codes. The presented paper is a component of a comprehensive investigation which containing three variables i) high axial load ratio defined as axial load divided by the axial capacity, ii) high shear demand defined as the ratio of shear demand at flexural yielding to shear resistance and iii) low transverse reinforcement ratio owing to large spacing among steel reinforcements. Thus, a total of four full-scale square RC columns comprised of i) one column designed to comply with the former Turkish Seismic Design Code (TSDC, 1975) and ii) three columns which are not compliant to any design codes (referred as sub-standard), were tested under high axial load ratio, 0.4 for code-conforming and 0.75 for sub-standard columns, combined with reversed cyclic lateral loading. The columns were also designed to have high shear demand in the order of 0.62 and 0.80 for bare sub-standard according to ACI 318 (2019) and TBEC (2018) design codes as sometimes observed in existing sub-standard structures. In addition to that, the ratio of shear demand for the code-conforming column is calculated 0.43 and 0.50 as per design codes, respectively. Besides, the ratio of transverse reinforcement area to the minimum required transverse reinforcement area was 0.19 and 0.77 for sub-standard columns according to ACI 318 (2019) and TBEC (2018), respectively. For the code-conforming column, the aforementioned ratio was 0.57 and 1.32 for both design codes, in the same manner. One of the sub-standard columns was kept as a reference column while the other two of them have been externally jacketed with one layer or two layers of carbon fiber-reinforced polymer (CFRP) sheets. Test results pointed out that the confinement provided by CFRP jacketing has remarkably improved the performance of seismically-deficient RC columns subjected to high axial compression under high shear demand in terms of lateral load capacity and ductility. The experimental results were also supplemented with theoretical work to evaluate the effects of CFRP jacketing on the seismic behavior of sub-standard RC columns.
  • Conference Object
    Citation - WoS: 1
    Citation - Scopus: 2
    Seismic Performance of Substandard Rc Columns Retrofitted With Sprayed Gfrm
    (Springer, 2022) Kian, Nima; Demir, Uğur; Demir, Cem; Maraşlı, Muhammed; İlki, Alper
    There is a myriad amount of substandard reinforced concrete (RC) buildings in developing countries that do not comply with the requirements and instructions of the current building design codes. In particular, columns in these substandard buildings demonstrate unsatisfactory and undesired behavior against lateral loads, mainly due to low concrete compressive strength and poor reinforcement detailing. The problem is exacerbated when the axial load ratio (ratio of applied axial load to the axial load capacity) and/or the shear ratio (ratio of shear force corresponding to moment capacity (Ve) to the shear capacity (Vr)) is/are high, leading to brittle failure modes. In this study, three full-scale substandard RC columns subjected to high axial load ratio of 0.75 were tested under constant axial load combined with reversed cyclic lateral displacements. Shear ratio (Ve/Vr) of the substandard columns were 0.75 and 0.82 according to ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and (Turkish Building Earthquake Code (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), respectively. According to the TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), columns had a high Ve/(fctmbd) ratio of 1.12, where, fctm, b, and d are the direct tensile strength of concrete, width of the cross-section, and effective depth of the section. The ratio of transverse reinforcement to minimum required transverse reinforcement according to the ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey) was 0.19 and 0.77, respectively. Two of the columns were retrofitted with an innovative, cost-effective, and easily-applicable strengthening method, through external jacketing with sprayed glass fiber reinforced mortar (GFRM) of different characteristics. The remaining column was tested as the reference specimen to evaluate the efficiency of the strengthening method. The test results demonstrated the extremely poor performance of the reference substandard column as well as the remarkable lateral load capacity and ductility improvement provided by the adopted novel strengthening approach.
  • Article
    Citation - WoS: 61
    Citation - Scopus: 60
    Performance of Structures in Izmir After the Samos Island Earthquake
    (Springer, 2021) Yakut, Ahmet; Sucuoğlu, Haluk; Binici, Barış; Canbay, Erdem; Dönmez, Cemalettin; İlki, Alper; Caner, Alp
    The October 30, 2020 Earthquake caused unexpectedly significant damage in Izmir considering its distance to the city. This paper evaluates the recorded ground motions, summarizes the performance of structures affected from the earthquake with emphasis on the reasons of damage. A detailed damage assessment was carried out by the Earthquake Engineering Research Center of Middle East Technical University to compile data on the damage of RC and masonry buildings. It was observed that majority of the damage was concentrated in the Bayrakli district due to its peculiar soil properties where many 7-10 story mid-rise RC buildings suffered heavy damage and collapse. The level of amplified ground motions combined with deficiencies of apparently non-code compliant buildings exacerbated the damage. The main reasons of damage were mainly attributed to the presence of soft stories, lack of proper detailing, poor construction quality, presence of heavy overhangs, and hence significant lack of code-compliance in essence. The influence of infill walls on seismic performance of deficient and inadequate buildings was clearly seen in this earthquake. This paper also discusses seismic code requirements in effect and their influence on the observed building performance. The recorded ground motions were compared with the code spectra to evaluate the performance of the buildings. The code response spectra were found to be well above the recorded ground motion spectra at the sites where significant damage was observed.