Civil Engineering / İnşaat Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/13

Browse

Search Results

Now showing 1 - 7 of 7
  • Article
    Citation - WoS: 61
    Citation - Scopus: 60
    Performance of Structures in İzmir After the Samos Island Earthquake
    (Springer, 2022) Yakut, A.; Sucuoǧlu, H.; Binici, B.; Canbay, E.; Dönmez, C.; Ilki, A.; Ay, B.Ö.
    The October 30, 2020 Earthquake caused unexpectedly significant damage in İzmir considering its distance to the city. This paper evaluates the recorded ground motions, summarizes the performance of structures affected from the earthquake with emphasis on the reasons of damage. A detailed damage assessment was carried out by the Earthquake Engineering Research Center of Middle East Technical University to compile data on the damage of RC and masonry buildings. It was observed that majority of the damage was concentrated in the Bayraklı district due to its peculiar soil properties where many 7–10 story mid-rise RC buildings suffered heavy damage and collapse. The level of amplified ground motions combined with deficiencies of apparently non-code compliant buildings exacerbated the damage. The main reasons of damage were mainly attributed to the presence of soft stories, lack of proper detailing, poor construction quality, presence of heavy overhangs, and hence significant lack of code-compliance in essence. The influence of infill walls on seismic performance of deficient and inadequate buildings was clearly seen in this earthquake. This paper also discusses seismic code requirements in effect and their influence on the observed building performance. The recorded ground motions were compared with the code spectra to evaluate the performance of the buildings. The code response spectra were found to be well above the recorded ground motion spectra at the sites where significant damage was observed. © 2021, The Author(s), under exclusive licence to Springer Nature B.V.
  • Book Part
    Design and Construction of a Test Setup To Investigate Ground Settlement Response of Large-Scale Masonry Building Models
    (Springer, 2023) Liu, Yiyan; Dalgıç, Korhan Deniz; Yeşilyurt, Cennet; Gülen, Burcu; Açıkgöz, Sinan; Maraşlı, Muhammed; İlki, Alper
    Underground construction activities such as tunnelling and deep excavations in urban areas may impact a significant number of surface structures and cause damage. Tunnelling-induced damage can often be repaired, but at great expense, due to significant repair costs and associated project delays. Within this context, damage caused by excavation-induced ground movements on heritage masonry buildings requires further attention, due to the cultural value and vulnerability of these assets. There is a need for experimental studies to better understand the structural response of these buildings to excavation-induced ground movements. In this study, a test setup was designed and constructed to examine the response of an experimental building model, replicating historic masonry structures, against differential settlement effects. The settlement apparatus relies on controlled jacking of large steel beams to apply differential displacements to the building. A specific tunneling scenario was considered for the design of the settlement apparatus. The constructed test setup is validated by evaluating the displacement profiles of the steel beam for different tests, with or without building. Differences between the differential settlements experienced by the steel beam and the building highlights how building weight and progressive damage may increase compliance to ground movements. © 2023, The Author(s), under exclusive license to Springer Nature Switzerland AG.
  • Conference Object
    Citation - Scopus: 3
    Seismic Performance of Cfrp Jacketed Sub-Standard Rc Columns Under High Axial Stress and Shear Demand
    (Springer, 2022) Demir, Merve Nur; Demir, Uğur; Demir, Cem; İlki, Alper
    In the last decades, lessons learnt from the major earthquakes, that occurred in many countries, brought revisions in prevailing seismic design codes. As a consequence of this phenomenon, the current building stock in Turkey is mainly comprised of reinforced concrete (RC) buildings which were designed according to different seismic design codes. The presented paper is a component of a comprehensive investigation which containing three variables i) high axial load ratio defined as axial load divided by the axial capacity, ii) high shear demand defined as the ratio of shear demand at flexural yielding to shear resistance and iii) low transverse reinforcement ratio owing to large spacing among steel reinforcements. Thus, a total of four full-scale square RC columns comprised of i) one column designed to comply with the former Turkish Seismic Design Code (TSDC, 1975) and ii) three columns which are not compliant to any design codes (referred as sub-standard), were tested under high axial load ratio, 0.4 for code-conforming and 0.75 for sub-standard columns, combined with reversed cyclic lateral loading. The columns were also designed to have high shear demand in the order of 0.62 and 0.80 for bare sub-standard according to ACI 318 (2019) and TBEC (2018) design codes as sometimes observed in existing sub-standard structures. In addition to that, the ratio of shear demand for the code-conforming column is calculated 0.43 and 0.50 as per design codes, respectively. Besides, the ratio of transverse reinforcement area to the minimum required transverse reinforcement area was 0.19 and 0.77 for sub-standard columns according to ACI 318 (2019) and TBEC (2018), respectively. For the code-conforming column, the aforementioned ratio was 0.57 and 1.32 for both design codes, in the same manner. One of the sub-standard columns was kept as a reference column while the other two of them have been externally jacketed with one layer or two layers of carbon fiber-reinforced polymer (CFRP) sheets. Test results pointed out that the confinement provided by CFRP jacketing has remarkably improved the performance of seismically-deficient RC columns subjected to high axial compression under high shear demand in terms of lateral load capacity and ductility. The experimental results were also supplemented with theoretical work to evaluate the effects of CFRP jacketing on the seismic behavior of sub-standard RC columns.
  • Conference Object
    Citation - WoS: 1
    Citation - Scopus: 2
    Seismic Performance of Substandard Rc Columns Retrofitted With Sprayed Gfrm
    (Springer, 2022) Kian, Nima; Demir, Uğur; Demir, Cem; Maraşlı, Muhammed; İlki, Alper
    There is a myriad amount of substandard reinforced concrete (RC) buildings in developing countries that do not comply with the requirements and instructions of the current building design codes. In particular, columns in these substandard buildings demonstrate unsatisfactory and undesired behavior against lateral loads, mainly due to low concrete compressive strength and poor reinforcement detailing. The problem is exacerbated when the axial load ratio (ratio of applied axial load to the axial load capacity) and/or the shear ratio (ratio of shear force corresponding to moment capacity (Ve) to the shear capacity (Vr)) is/are high, leading to brittle failure modes. In this study, three full-scale substandard RC columns subjected to high axial load ratio of 0.75 were tested under constant axial load combined with reversed cyclic lateral displacements. Shear ratio (Ve/Vr) of the substandard columns were 0.75 and 0.82 according to ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and (Turkish Building Earthquake Code (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), respectively. According to the TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), columns had a high Ve/(fctmbd) ratio of 1.12, where, fctm, b, and d are the direct tensile strength of concrete, width of the cross-section, and effective depth of the section. The ratio of transverse reinforcement to minimum required transverse reinforcement according to the ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey) was 0.19 and 0.77, respectively. Two of the columns were retrofitted with an innovative, cost-effective, and easily-applicable strengthening method, through external jacketing with sprayed glass fiber reinforced mortar (GFRM) of different characteristics. The remaining column was tested as the reference specimen to evaluate the efficiency of the strengthening method. The test results demonstrated the extremely poor performance of the reference substandard column as well as the remarkable lateral load capacity and ductility improvement provided by the adopted novel strengthening approach.
  • Conference Object
    Citation - Scopus: 3
    Large Scale Experimental Settlement Tests To Evaluate Structural Models for Tunnelling-Induced Damage Analysis
    (Springer, 2021) Dalgıç, Korhan Deniz; Gülen, D. Burcu; Açıkgöz, Sinan; Burd, Harvey; Hendriks, Max A.N.; Giardina, Giardina; İlki, Alper
    Underground construction activities, such as tunnelling, cause local ground movements to occur. Nearby surface structures interact with the moving ground, potentially leading to building damage. Although it is understood that the severity of building damage is influenced by the façade opening ratio (OpR) and the stiffness of the floors, experimental work in this area is lacking. This paper describes the specification and design of an experimental campaign on brick masonry buildings subjected to vertical base movements. The specimens are half-scale models of walls of two-storey buildings; models with different window arrangements and with/without floor slabs are examined. To design the experimental setup, 3D finite element analyses of the model walls were conducted. Key analysis results, presented in this paper, indicate how the examined structural properties (OpR, building weight, floor stiffness) are expected to influence the patterns of damage in the masonry. The finite element results are also used to design an instrumentation system comprising Fibre Bragg Grating (FBG) sensors and a digital image correlation (DIC) system. Data from the tests will support the formulation and validation of structural models for predicting tunnelling-induced damage in masonry buildings. © 2021, The Author(s), under exclusive license to Springer Nature Switzerland AG.
  • Book Part
    Suspended Sediment Concentration in Stratified Lakes Estimated by Acoustic Methods
    (Springer, 2012) Elçi, Şebnem
    [No abstract available]
  • Book Part
    Citation - Scopus: 4
    Strain gradient crystal plasticity: Intergranularmicrostructure formation
    (Springer, 2019) Özdemir, İzzet; Yalçınkaya, Tuncay
    This chapter addresses the formation and evolution of inhomogeneous plastic deformation field between grains in polycrystalline metals by focusing on continuum scale modeling of dislocation-grain boundary interactions within a strain gradient crystal plasticity (SGCP) framework. Thermodynamically consistent extension of a particular strain gradient plasticity model, addressed previously (see also, e.g., Yalcinkaya et al, J Mech Phys Solids 59:1-17, 2011), is presented which incorporates the effect of grain boundaries on plastic slip evolution explicitly. Among various choices, a potential-type non-dissipative grain boundary description in terms of grain boundary Burgers tensor (see, e.g., Gurtin, J Mech Phys Solids 56:640-662, 2008) is preferred since this is the essential descriptor to capture both the misorientation and grain boundary orientation effects. A mixed finite element formulation is used to discretize the problem in which both displacements and plastic slips are considered as primary variables. For the treatment of grain boundaries within the solution algorithm, an interface element is formulated. The capabilities of the framework is demonstrated through 3D bicrystal and polycrystal examples, and potential extensions and currently pursued multi-scale modeling efforts are briefly discussed in the closure. © Springer Nature Switzerland AG 2019. All rights reserved.