WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
14 results
Search Results
Article Hydrogeochemical Assessment and Health Risks of Groundwater in Sahand Volcanic Foreland (NW Iran): Arsenic Speciation and Heavy Metal Risk Indicators(Academic Press Inc Elsevier Science, 2026) Ghayurdoost, Farhad; Zarghami, Mahdi; Sadeghfam, Sina; Jabraili-Andaryan, Nasser; Nikmaram, Sara; Baba, Alper; Mosaferi, MohammadDue to the toxic nature of arsenic (As) and its elevated concentrations in many water resources, numerous studies have focused on understanding its origin, distribution, and impacts. This study aimed to identify the dominant As species in groundwater of the Sahand Volcanic Foothills, assess water quality indices, and examine heavy metal (HM) concentrations to address rising concerns about groundwater contamination. A total of 21 groundwater samples were collected and analyzed in accordance with world health organization (WHO) guidelines. Although most samples fell within acceptable ranges, several (notably S10, S20, and S21) exhibited elevated levels of total dissolved solids (TDS), electrical conductivity (EC), and HMs, particularly iron (Fe) and As. Hydrochemical assessments using Piper, Gibbs, Stiff, and Schoeller diagrams indicated that geochemical processes resulting from rock dissolution were the main factors controlling groundwater chemistry, with limited influence from anthropogenic pollution. According to the groundwater quality index (GWQI), most samples were categorized as "good" to "excellent," though some areas ranged from "moderate" to "very poor." HM pollution indices revealed that As concentrations exceeded permissible limits. Health risk assessments further showed that both oral and dermal exposure posed significant carcinogenic and non-carcinogenic risks, especially for children. Speciation analysis indicated that arsenate (As V) was the dominant form of As, consistent with oxidizing aquifer conditions, and is less biologically hazardous than arsenite (As III). The study highlights the necessity of continuous groundwater monitoring, effective pollution source management, and implementation of protective regulations to mitigate environmental and health risks in the region.Article Citation - WoS: 8Citation - Scopus: 8Removal of Arsenic in Groundwater From Western Anatolia, Turkey Using an Electrocoagulation Reactor With Different Types of Iron Anodes(Elsevier, 2022) Kobya, Mehmet; Dolaz, Mustafa; Özaydın Şenol, Burcu; Gören, Ayşegül YağmurElectrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 μg L−1, GW-2: 1132.1 μg L−1, and GW-3: 52, 000 μg L−1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 μg L−1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As removal efficiency, EC time, and operating cost were >99.9%, 180 min and 0.406 $ m−3 for ball anodes, >99.9%, 100 min and 0.0813 $ m−3 for plate anodes, >99.9%, 80 min and 0.0815 $ m−3 for scrap anodes for GW-3, respectively. It was observed that as the As concentration in the GW increased, the EC time and operating cost increased. Overall, it was concluded that Fe scrap anodes are more advantageous than other types of anodes in terms of operating cost in EC reactor for As removal.Article Citation - WoS: 26Citation - Scopus: 34Arsenite Removal From Groundwater in a Batch Electrocoagulation Process: Optimization Through Response Surface Methodology(Taylor & Francis, 2019) Şık, Emrah; Gören, Ayşegül Yağmur; Demirbaş, Erhan; Kobya, Mehmet; Öncel, Mehmet SalimIn this study, influences of seven process variables such as initial pH (pH(i)), applied current (i), operating time (t(EC)), initial As(III) concentration (C-o), diameter of Fe ball anode (d(p)), column height in the electrocoagulation (EC) reactor (h) and airflow rate (Q(air)) for removal of As(III) from groundwater by a new air-fed fixed-bed EC reactor were evaluated with a response surface methodology (RSM). The proposed quadratic model fitted very well with the experimental data for the responses. The removal efficiencies and operating costs were determined to be 99% and 0.01 $/m(3) at the optimum operating conditions (a pH(i) of 8.5, 0.05 A, 4.94 min, d(p) of 9.24 mm, h of 7.49 cm, Q(air) of 9.98 L/min for 50 mu g/L). This study clearly showed that the RSM in the EC process was a very suitable method to optimize the operating conditions at the target value of effluent As(III) concentration (10 mu g/L) while keeping the operating cost to minimal and maximize the removal efficiency.Article Citation - WoS: 3Citation - Scopus: 6Optimization of Some Cations for Removal of Arsenic From Groundwater by Electrocoagulation Process(Gheorghe Asachi Technical University of Iasi, 2018) Kobya, Mehmet; Şık, Emrah; Demirbaş, Erhan; Gören, Ayşegül Yağmur; Öncel, Mehmet SalimThis study dealt with investigation of arsenic removal from groundwater using electrocoagulation (EC) method in a batch mode by the Box-Behnken experimental design method. Effects of some cations like Ca, Fe, Mg, Mn and operating time on the removal were explored by an air injected EC reactor. The combined effects of these variables were analyzed by the quadratic model for predicting the highest removal efficiency of arsenic from groundwater. The arsenic removal efficiency was found to be dependent on increase with operating time and concentrations of Ca, Mg, Fe and lower concentration of Mn. When operating variables were considered as minimum operating cost and maximum removal efficiency, the optimum operating parameters were determined to be 132 mg/L of CCa, 55 mg/L of CMg, 4.5 mg /L of CFe, 4.5 mg/L of CMn and operating time of 3 min to meet the target concentration of <10 μg/L. Values of removal efficiency and operating cost at the optimum conditions were 95.1% and 0.041 $/m3.Conference Object Citation - WoS: 2Citation - Scopus: 2Arsenic in Groundwater in Western Anatolia, Turkey: a Review(University of Silesia Press, 2010) Gündüz, Orhan; Baba, Alper; Elpit, HandanOccurrence of arsenic (As) in groundwater has been a major problem worldwide for the last hundred years. Considering its toxic effects on human health, the presence of elevated levels of arsenic in groundwater resources used in drinking water supply has been an active research field throughout the world (Van Halem et al., 2009). In this regard, case studies from Bangla-desh, India, Nepal, El Salvador, Ecuador, Honduras, Mexico, Chile, China, Canada, Argentina, Peru, Taiwan, United States, Bolivia and Turkey have been documented with regards to the detection of natural levels in groundwater, the occurrence and distribution mechanisms, the human health effects and the in-situ and ex-situ treatment techniques (Jean et al., 2010). In many of these locations, arsenic is naturally found in the subsurface strata within volcanic and sedimentary formations as well as in areas of geothermal systems related to tectonic activity. Western Anatolia in Turkey is one such area of complex geology with active tectonics and high geothermal potential. This natural setting serves as a suitable environment for the presence of high levels of arsenic in subsurface waters. Based on these fundamentals, this study presents a general overview of arsenic presence in western Anatolia.Article Citation - WoS: 3Citation - Scopus: 5Groundwater in Local Development Strategies: Case of Izmir(IWA Publishing, 2018) Velibeyoğlu, Koray; Yazdani, Hamidreza; Baba, AlperThis study takes into account groundwater in local development strategies of Izmir, in which rapid and uneven development has occurred in recent decades. Therefore, resilience thinking is needed in the future development of the city-region. To this end, the paper aims to make an analysis of recently completed asset-based local development strategies for Izmir city towards water resiliency. The methodology has two main steps. Firstly, by using spatial interaction analysis of peninsula and river basins, potential vulnerabilities and risks are indicated. Secondly, a stratified model of strategy evaluation is conducted by scrutinizing the existing layered approaches. Then, these models were applied to all strategic decisions including water resources and indicated a high level of consistency to achieve sustainable and resilient use of blue-green infrastructure in the future of Izmir’s metropolitan area. Local assets, including water resources, are the backbone of future development of the Izmir city-region. Therefore, usage of local assets in a multi-level perspective of strategy development needs to be understood. The stratified model denotes that special emphasis should be given to different river basins in different levels. This study illustrates that synergy management is needed between different layers of local development strategies, in which the role of urban and rural households is of the utmost importance.Article Citation - WoS: 18Citation - Scopus: 22The Health Risk Associated With Chronic Diseases in Villages With High Arsenic Levels in Drinking Water Supplies(Springer Verlag, 2017) Gündüz, Orhan; Bakar, Coşkun; Şimşek, Celalettin; Baba, Alper; Elçi, Alper; Gürleyük, Hakan; Mutlu, Merdiye; Çakır, AyşeThis study is intended to compare and assess the distribution and possible causes of current chronic diseases in villages with high arsenic levels in drinking water supplies. It is a cross-sectional epidemiological research that analyzes the frequency and underlying risk factors of chronic diseases in villages with varying levels of arsenic exposure through drinking water. Sample space of study included 1003 individuals, 614 of whom were from villages with high arsenic levels in drinking water and remaining 389 were from two control villages with below-limit arsenic levels in drinking water. While nutritional habits and living environments of two groups were similar, cigarette smoking and alcohol use were higher in villages with low arsenic levels. Mini mental state examination test results in 60+ age group were lower in villages with high arsenic levels. Although no statistically significant differences were detected in chronic disease occurrence between the groups, the number of cases was higher in villages with higher percentage of cigarette smoking and alcohol use. Moreover, cases of lung, colon, and stomach cancers were higher in villages with high arsenic levels in drinking water supplies.Article Citation - WoS: 28Citation - Scopus: 29Arsenite and Arsenate Removals From Groundwater by Electrocoagulation Using Iron Ball Anodes: Influence of Operating Parameters(Elsevier Ltd., 2017) Şık, E.; Demirbaş, Erhan; Gören, Ayşegül Yağmur; Öncel, Mehmet Salim; Kobya, MehmetRemovals of arsenite (As(III)) and arsenate (As(V)) from groundwater by a cylindrical packed-bed electrocoagulation (EC) reactor using Fe ball anodes were investigated in this study. Effects of some operating parameters such as initial pH (pHi of 6.5–8.5), applied current (i of 0.075–0.30 A), initial concentration (Co of 30–200 μg/L), diameter of iron ball (dp of 5.0–10.0 mm), height of anode balls in the reactor (h of 2–8 cm) and airflow rate (Qair of 0.0–6.0 L/min) on the removal efficiency of arsenic were evaluated. The removal efficiency of arsenic decreased with increase in concentrations of arsenic from 30 to 200 μg/L while its removal efficiency increased with increase in operating time, applied current, height of anode in the reactor, and airflow rate. The optimum operating conditions for effective As(III) and As(V) removals to meet the permissible level of arsenic effluent concentration of <10 μg/L were determined as 0.3 A, 14 min of EC time for As(III) and 12 min for As(V), a pHi of 7.5, Co of 200 μg/L, dp of 7.5 mm, h of 7.5 cm and Qair of 6 L/min, respectively. Arsenic removal efficiency, energy and electrode consumptions, operating cost, charge loading and arsenic removed capacity per amount of electrochemically generated Fe at the optimum conditions were also calculated as 96.0%, 1.442 kWh/m3, 0.0752 kg/m3, 0.612 $/m3, 252 C and 2.55 μg/mg Fe (0.762 μg/C) for As(III) removal and 95.8%, 1.386 kWh/m3, 0.0628 kg/m3, 0.546 $/m3, 216 C and 3.05 μg/mg Fe (0.887 μg/C) for As(V) removal, respectively.Article Citation - WoS: 14Citation - Scopus: 17Blowout Mechanism of Alasehir (turkey) Geothermal Field and Its Effects on Groundwater Chemistry(Springer Verlag, 2017) Rabet, Rita Sandrina; Şimşek, Celalettin; Baba, Alper; Murathan, AlimAnatolia region is one of the most seismically active regions in the world and has a considerably high level of geothermal energy potential. Some of these geothermal resources have been used for power generation and direct heating. Most of the high enthalpy geothermal systems are located in western part of Turkey. Alasehir is the most important geothermal site in western part of Turkey. Many geothermal wells have been drilled in Alasehir Plain to produce the geothermal fluid from the deep reservoir in the last 10 years. A blowout accident happened during a geothermal well drilling operation in Alasehir Plain, and significant amount of geothermal fluid surfaced out along the fault zone in three locations. When drilling string entered the reservoir rock about 1000 m, blowout occurred. As the well head preventer system was closed because of the blowout, high-pressure fluid surfaced out along the fault zone cutting the Neogene formation. In order to understand the geothermal fluid effects on groundwater chemistry, physical and chemical compositions of local cold groundwater were monitored from May 2012 to September 2014 in the study area. The geothermal fluid was found to be of Na–HCO3 water type, and especially, arsenic and boron concentrations reached levels as high as 3 and 127 mg/L, respectively. The concentrations of arsenic and boron in the geothermal fluid and groundwater exceeded the maximum allowable limits given in the national and international standards for drinking water quality. According to temporally monitored results, geothermal fluid has extremely high mineral content which influenced the quality of groundwater resources of the area where water resource is commonly used for agricultural irrigation.Article Citation - WoS: 27Citation - Scopus: 31Statistical Analysis of Causes of Death (2005-2010) in Villages of Simav Plain, Turkey, With High Arsenic Levels in Drinking Water Supplie(Taylor and Francis Ltd., 2015) Gündüz, Orhan; Bakar, Coşkun; Şimşek, Celalettin; Baba, Alper; Elçi, Alper; Gürleyük, Hakan; Mutlu, Merdiye; Çakır, AyşeThe purpose of this research was to compare the causes of death in 5 villages situated in Simav Plain, Turkey, during 2005-2010 where different arsenic levels were detected in drinking water supplies. Since groundwater in Simav Plain had arsenic concentrations that ranged between 7.1 and 833.9 ppb, a two-phase research was formulated. In the first phase, public health surveys were conducted with 1,003 villagers to determine the distribution of diseases. In the second phase, verbal autopsy surveys and official death records were used to investigate the causes of death. In total, 402 death cases were found in the study area where cardiovascular system diseases (44%) and cancers (15.2%) were major causes. Cancers of lung (44.3%), prostate (9.8%), colon (9.8%), and stomach (8.2%) were comparably higher in villages with high arsenic levels in drinking water supplies. Furthermore, the majority of cases of liver, bladder, and stomach cancers were observed in villages with high arsenic levels. © 2015 Taylor and Francis Group, LLC.
