    Modeling of Low Temperature Geothermal District Heating Systems
    (Taylor and Francis Ltd., 2004) Yıldırım, Nurdan; Gökçen Akkurt, Gülden; Gökçen, Gülden; Yıldırım, Nurdan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    In this work, low temperature geothermal district heating systems with heat pumps have been studied and compared with fuel-oil boiler heating systems for intermittent and continuous regimes according to the optimum indoor air temperature and operational cost. Izmir Institute of Technology (IZTECH) Campus is taken as a case study. Various heat pump and boiler configurations are studied to meet required duty. Operational cost analysis for each alternative is conducted. According to the results, for IZTECH Campus the best alternative, which gives the optimum indoor air temperature and the lowest operational cost, is heat pump continuous regime.
  • Conference Object
    Heat Load Factor for Geothermal District Heating System Design
    (National Technical University of Athens, 2006) Yıldırım, Nurdan; Gökçen Akkurt, Gülden; Gökçen, Gülden; Yıldırım, Nurdan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Design of heating systems using conventional fuels is based on peak load which is calculated according to the coldest outdoor design temperature. But in geothermal district heating system design it is common practice to use a heat load factor between 0.6-0.7 since the resource is continues, cheap and system can be run for 24 hours a day. Heat load factor can be defined as a ratio of actual heat load to design heat load of the system. In this study, a geothermal district heating system is designed for Izmir Institute of Technology Campus, Izmir, Turkey and simulated for a heat load factor range of 0.5-1. For the Campus case, the heat load factor is determined as 0.53-0.0.67 based on indoor air temperature and operational cost.
  • Article
    Citation - WoS: 66
    Citation - Scopus: 79
    Piping Network Design of Geothermal District Heating Systems: Case Study for a University Campus
    (Elsevier Ltd., 2010) Yıldırım, Nurdan; Toksoy, Macit; Yıldırım, Nurdan; Toksoy, Macit; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Geothermal district heating system design consists of two parts: heating system and piping network design. District heating system design and a case study for a university campus is given in Yildirim et al. [1] in detail. In this study, piping network design optimisation is evaluated based on heat centre location depending upon the cost and common design parameters of piping networks which are pipe materials, target pressure loss (TPL) per unit length of pipes and installation type. Then a case study for the same campus is presented. © 2010 Elsevier Ltd.