WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7150

Browse

Search Results

Now showing 1 - 8 of 8
  • Article
    Citation - WoS: 40
    Citation - Scopus: 47
    Boron in Geothermal Energy: Sources, Environmental Impacts, and Management in Geothermal Fluid
    (Elsevier, 2022) Mott, A.; Baba, Alper; Hadi Mosleh, Mojgan; Ökten, Hatice Eser; Babaei, Masoud; Gören, Ayşegül Yağmur; Feng, C.; Recepoğlu, Yaşar Kemal; Uzelli, Taygun; Uytun, Hüseyin; Morata, Diego; Yüksel Özşen, Aslı
    The problem of hazardous chemicals in geothermal fluid is a critical environmental concern in geothermal energy developments. Boron is among the hazardous contaminants reported to be present at high concentrations in geothermal fluids in various countries. Poor management and inadequate treatment of geothermal fluids can release excessive boron to the environment that has toxic effects on plants, humans, and animals. Despite the importance of boron management in geothermal fluid, limited and fragmented resources exist that provide a comprehensive understanding of its sources, transport and fate, and the treatment strategies in geothermal energy context. This paper presents the first critical review from a systematic and comprehensive review on different aspects of boron in geothermal fluid including its generation, sources, toxicity, ranges and the management approaches and treatment technologies. Our research highlights the origin of boron in geothermal water to be mainly from historical water-rock interactions and magmatic intrusion. Excessive concentrations of boron in geothermal fluids have been reported (over 500 mg/L in some case studies). Our review indicated that possible boron contamination in geothermal sites are mostly due to flawed construction of production/re-injection wells and uncontrolled discharge of geothermal water to surface water. The dominancy of non-ionic H3BO3 species makes the selection of the suitable treatment method for geothermal waters limited. Combining boron selective resins and membrane technologies, hybrid systems have provided effluents suitable for irrigation. However, their high energy consumption and course structure of boron selective resins encourage further research to develop cost-effective and environmentally friendly alternatives.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 11
    Utilization of Membrane Separation Processes for Reclamation and Reuse of Geothermal Water in Agricultural Irrigation of Tomato Plants-Pilot Membrane Tests and Economic Analysis
    (Elsevier, 2022) Jarma, Yakubu A.; Karaoğlu, Aslı; Senan, Islam Rashad Ahmed; Meriç, Mehmet Kamil; Kukul, Yasemin Senem; Özçakal, Emrah; Barlas, Neriman Tuba; Çakıcı, Hakan; Baba, Alper; Kabay, Nalan
    The quality of irrigation water is critical for enhancing agricultural productivity. As a result, this research was carried out with the aim of treating spent geothermal water before it is used for agricultural irrigation. While doing that, cost analysis of the system was taken into consideration as well. The product water was targeted to suit irrigation water standards for tomato plants. Two commercially available pressure driven membranes (NF8040-70 as NF membrane and TM720D-400 as RO membrane) were employed for this task. A constant applied pressure of 15 bar and 60% of water recovery were kept constant during the product water production while mode of operation for the membrane system was continuous. According to Turkish Ministry of Environment and Urbanization irrigation water standards and the results obtained from this study, it was clearly seen that both NF and RO product waters meet the quality I class irrigation water standards with respect total dissolved substances (TDS), electrical conductivity (EC), concentrations of Na+ and Cl− ions. Quality 1 means that the produced water will not cause any environmental effect when employed for irrigation purpose. Nevertheless, the produced water was found not to obey the irrigation standards with respect to sodium adsorption ratio (SAR) and boron concentration (quality III class). Quality III explains that the water will cause soil infiltration problems when employed for irrigation purpose. Since most of the minerals needed for plant growth were rejected by NF and RO membranes, an appropriate mixing ratio of the product water with well water for remineralization was determined. Mixing 50 and 60% of well water with the product waters of NF (50%) and RO (40%) membranes, respectively was found to be the optimum mixing ratios to produce the requested water quality for tomato irrigation. Quality II class irrigation water which can be applied with caution was targeted in terms of SAR as well as boron concentration (2–4 and 4–6 mg/L) while determining the mixing ratios. The cost of the product water was found as 0.76 and 1.56$/m3 for NF and RO processes, respectively.
  • Article
    Citation - WoS: 8
    Citation - Scopus: 11
    Brine Minimization in Desalination of the Geothermal Reinjection Fluid by Pressure-Driven Membrane Separation Processes
    (Elsevier, 2022) Jarma, Yakubu A.; Karaoğlu, Aslı; Senan, Islam Rashad Ahmed; Baba, Alper; Kabay, Nalan
    Brine obtained during water treatment by pressure driven membrane processes remains the major drawback. Therefore, it is of paramount important to find a lasting solution in order to minimize its production by both nanofiltration (NF) and reverse osmosis (RO) membranes. In this study, an experimental study with the aim of brine minimization during membrane desalination of the geothermal reinjection fluid using a mini-pilot scale membrane test system having spiral wound NF and RO membranes was conducted. The membranes employed for this task were TR-NF and BW30-RO membranes. First, studies with different brine to feed ratios of 1:4, 1:3, 1:2 and 2:3 represented as NF-F2, NF-F3, NF-F4 and NF-F5, respectively were investigated using TR-NF membrane. A control study with no brine recirculation was conducted as well in order to check the effect of brine recirculation on the membrane performance. Secondly, studies with BW30-RO membrane using same brine to feed ratios as in the case of NF membrane studies were carried out. An applied pressure of 15 bar, initial water recovery of 60% and 4 h of experimental time were employed as operational conditions for both NF and RO membrane studies. Based on the results obtained, it was found that the brine recirculation (with a brine to fresh feed ratio of 2:3) has a significant impact on the permeate flux. The product water can be utilized for the agricultural irrigation purposes. Nevertheless, the boron concentration in the product water was still high for the sensitive crops.
  • Article
    Citation - WoS: 13
    Citation - Scopus: 18
    Integrated Pressure-Driven Membrane Separation Processes for the Production of Agricultural Irrigation Water From Spent Geothermal Water
    (Elsevier, 2022) Jarma, Yakubu Abdullahi; Karaoğlu, Aslı; Tekin, Özge; Senan, Islam Rashad Ahmed; Baba, Alper
    The application of different pressure-driven membranes to treat the spent geothermal water to be used for agricultural irrigation was explored in this study. Firstly, individual performances of different commercially available nanofiltration (NF) and reverse osmosis (RO) membranes attached to a mini-pilot membrane test system were studied. For the single membrane test TR-NF and NF90 as NF membranes and TR-BWRO, Vontrone, TR-SWRO and BW30 as RO membranes were employed while combination of TR-NF with TR-BWRO, Vontrone, TR-SWRO and BW30 was employed in the integrated study (with and without pH adjustment).When performances of individual membranes were investigated, the permeate fluxes obtained it was found that there was no significant flux drop with the experimental time (4 h) in all the studies. In terms of boron removals, boron was partially removed in single membrane study as 22.7–23.6% and 30.6–56.8% by NF and RO membranes, respectively. For the integrated NF + RO membrane configuration (without pH adjustment), boron removals were in the range of 42.1–59.4% while 91.3–95.4% of boron removal was obtained in the integrated NF + RO (at elevated pH). It was found that the produced water complied with class I quality with respect to irrigation water parameters with the exception of boron and sodium adsorption ratio (SAR), while the pH of the product water in the integrated NF + RO study at elevated pH was found to be in class III. Hence, produced water will be suitable (class II) for irrigation if 30% of well water should be blended with the product water in the integrated NF + RO studies (with and without pH adjustment) as well as pH adjustment when necessary.
  • Article
    Citation - WoS: 58
    Citation - Scopus: 76
    Utilization of Renewable Energy Sources in Desalination of Geothermal Water for Agriculture
    (Elsevier, 2021) Tomaszewska, Barbara; Gökçen Akkurt, Gülden; Kaczmarczyk, Michal; Bujakowski, Wieslaw; Keleş, Nazlı; Jarma, Yakubu A.; Baba, Alper; Bryjak, Marek; Kabay, Nalan
    The agricultural sector, which is highly dependent on water, is urged to build on improved water management practices and explore available options to match supply and demand because of the water scarcity risks and a sustainable and productive agri-food chain. Geothermal water is an energy source used to generate electricity and/or heat. After harnessing its energy, the remaining water can be used as a water source for irrigation following treatment because of its high ionic content. Geothermal fields are mostly located in rural areas where agricultural activities exist. This would be a good match to decrease the transportation cost of irrigation water. The energy demand of the desalination process for agriculture is higher, requiring additional post-treatment processes. Fossil fuels to fulfill the energy requirements are becoming expensive, and greenhouse gas emissions are harmful to the environment. Thus, efforts should be directed towards integrating renewable energy resources into desalination process. This work focuses on presenting a comprehensive review of geothermal water desalination which is powered by renewable energy and provides specific cases from Turkey and Poland. Furthermore, possible new generation renewable energy systems in desalination are introduced, considering their potential application in the desalination of geothermal water for agricultural irrigation.
  • Article
    Citation - WoS: 15
    Citation - Scopus: 18
    Simultaneous Energy Production, Boron and Cod Removal Using a Novel Microbial Desalination Cell
    (Elsevier, 2021) Gören, Ayşegül Yağmur; Ökten, Hatice Eser
    This paper investigates simultaneous boron removal from aqueous solutions, organic matter removal from industrial wastewater and energy production using a Microbial Desalination Cell (MDC). Anode chamber of the conventional MDC cell was modified to include 3D cubic electrodes as a novel design. Effects of operating parameters, including electrode type (3D-electrode and 2D-electrode), anolyte solution temperature (20 °C, 40 °C, and 60 °C), and activated sludge:wastewater volumetric ratio (S:WW = 1:1, 1:2, and 1:5), on MDC performance were studied. Furthermore, real geothermal water treatment was investigated under optimum operating conditions. Boron and organic matter removal efficiencies and the produced power density results were promising for 3D-electrodes under optimum operating conditions. The maximum boron removal efficiency, COD removal efficiency, and power density were 55.5%, 91.5%, and 9.04 mW/m3 treating real geothermal water at optimum operating conditions. The analyses of Scanning Electron Microscope with Energy Dispersive X-ray spectrometer (SEM-EDX) demonstrated biofilm formation and salt deposition on membrane surfaces, which most probably reduced the performance of MDC. Consequently, our results showed that use of 3D-electrodes was a promising improvement to the conventional configurations with 2-D electrodes since removal efficiencies and energy production were comparable for a more compact electrode structure.
  • Article
    Citation - WoS: 58
    Citation - Scopus: 59
    Assessment of Different Nanofiltration and Reverse Osmosis Membranes for Simultaneous Removal of Arsenic and Boron From Spent Geothermal Water
    (Elsevier, 2021) Jarma, Yakubu A.; Karaoğlu, Aslı; Tekin, Özge; Baba, Alper; Ökten, H.Eser; Tomaszewska, Barbara; Kabay, Nalan
    One of the factors that determine agricultural crops’ yield is the quality of water used during irrigation. In this study, we assessed the usability of spent geothermal water for agricultural irrigation after membrane treatment. Preliminary membrane tests were conducted on a laboratory-scale set up followed by mini-pilot scale tests in a geothermal heating center. In part I, three commercially available membranes (XLE BWRO, NF90, and Osmonics CK- NF) were tested using a cross-flow flat-sheet membrane testing unit (Sepa CF II, GE-Osmonics) under constant applied pressure of 20 bar. In part II, different spiral wound membranes (TR-NE90-NF, TR-BE-BW, and BW30) other than the ones used in laboratory tests were employed for the mini-pilot scale studies in a continuous mode. Water recovery and applied pressure were maintained constant at 60% and 12 bar, respectively. Performances of the membranes were assessed in terms of the permeate flux, boron and arsenic removals. In laboratory tests, the permeate fluxes were measured as 94.3, 87.9, and 64.3 L m?2 h?1 for XLE BWRO, CK-NF and NF90 membranes, respectively. The arsenic removals were found as 99.0%, 87.5% and 83.6% while the boron removals were 56.8%, 54.2%, and 26.1% for XLE BWRO, NF90 and CK-NF membranes, respectively. In field tests, permeate fluxes were 49.9, 26.8 and 24.0 L m?2 h?1 for TR-NE90-NF, BW30-RO and TR-BE-BW membranes, respectively. Boron removals were calculated as 49.9%, 44.1% and 40.7% for TR-BE-BW, TR-NE90-NF and BW30-RO membranes, respectively. Removal efficiencies of arsenic in mini-pilot scale membrane tests were all over 90%. Quality of the permeate water produced was suitable for irrigation in terms of the electrical conductivity (EC) and the total dissolved solids (TDS) for all tested membranes with respect to guidelines set by the Turkish Ministry of Environment and Urbanisation (TMEU). However, XLE BWRO, CK-NF and NF90 membranes failed to meet the required limits for irrigation in terms of boron and arsenic concentrations in the product water. The permeate streams of TR-BE-BW, TR-NE90-NF and BW30-RO membranes complied with the irrigation water standards in terms of EC, TDS and arsenic concentration while boron concentration remained above the allowable limit. © 2020 Elsevier B.V.
  • Article
    Citation - WoS: 17
    Citation - Scopus: 19
    Effect of Operational Conditions on Separation of Lithium From Geothermal Water by ?-Mno2 Using Ion Exchange–membrane Filtration Hybrid Process
    (Taylor and Francis Ltd., 2018) Recepoğlu, Yaşar Kemal; Kabay, Nalan; Yoshizuka, Kazuharu; Nishihama, Syouhei; Yılmaz İpek, İdil; Arda, Müşerref; Yüksel, Mithat
    A hybrid system coupling ion exchange and ultrafiltration (UF) was employed to separate lithium from lithium-spiked geothermal water. The effect of process parameters such as adsorbent type, adsorbent dosage, permeate flow rate, and replacement speeds of fresh and saturated adsorbents have been evaluated to determine the efficiency of the hybrid system. According to the results obtained using λ-MnO2 derived from spinel-type lithium manganese dioxide, the optimal operating conditions to separate lithium from geothermal water were found with powdery λ-MnO2 with an adsorbent concentration of 1.5 g adsorbent/L solution, replacement rates of fresh and saturated adsorbents of 6.0 mL/min, and a permeate flow rate of 5.0 mL/min. The ion exchange–UF hybrid system providing an advantage to work with very fine particles easily can be considered as a favorable process for the separation of lithium from geothermal water.