WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
8 results
Search Results
Now showing 1 - 8 of 8
Article Citation - WoS: 11Citation - Scopus: 12Colorimetric and Fluorometric Profiling of Advanced Glycation End Products(American Chemical Society, 2022) Ammanath, Gopal; Delachi, Carla Giorgia; Karabacak, Soner; Ali, Yusuf; Boehm, Bernhard O.; Yıldız, Ümit Hakan; Alagappan, Palaniappan; Liedberg, BoProfiling of advanced glycation end products (AGEs) is an emerging area of clinical significance for disease diagnosis and prognosis. Typically, concentrations of AGEs are estimated in laboratories by trained personnel using sophisticated equipment. Herein, a facile approach for colorimetric and fluorometric profiling of AGEs is reported for rapid and on-site analysis. The concentrations of AGE levels in plasma are estimated via changes in optical properties of polythiophenes (PTs) upon interaction with aptamers (Apts) in the presence and in the absence of AGEs. To validate the proposed approach, glyceraldehyde-derived AGEs (AGE class 1 [AGE1]), the biomarker associated with cardiovascular diseases and diabetes, are used as a model system. Colorimetric analysis yielded linear responses for AGE1 for clinically relevant concentration ranges between 1.5 and 300 μg/mL with a limit of detection (LOD) of ∼1.3 μg/mL. Subsequently, an approach utilizing PTs with four different pendant groups in conjunction with four different Apts is demonstrated for qualitative colorimetric profiling and for quantitative fluorometric profiling of up to four AGEs in clinical matrices. Principal component analysis (PCA) of fluorometric responses of AGE-spiked samples yielded distinct responses for the different AGEs tested. Thus, the proposed approach ascertains rapid profiling of spiked AGEs in plasma samples without the requirement of preanalytical processing and advanced instrumentation, thereby facilitating on-site diagnosis.Article Citation - WoS: 7Citation - Scopus: 7A Perspective on Polythiophenes as Conformation Dependent Optical Reporters for Label-Free Bioanalytics(American Chemical Society, 2022) Sinsinbar, Gaurav; Palaniappan, Alagappan; Yıldız, Ümit Hakan; Liedberg, BoPoly(3-alkylthiophene) (PT)-based conjugated polyelectrolytes (CPEs) constitute an important class of responsive polymers with excellent optical properties. The electrostatic interactions between PTs and target analytes trigger complexation and concomitant conformational changes of the PT backbones that produce distinct optical responses. These conformation-induced optical responses of the PTs enable them to be utilized as reporters for detection of various analytes by employing simple UV-vis spectrophotometry or the naked eye. Numerous PTs with unique pendant groups have been synthesized to tailor their interactions with analytes such as nucleotides, ions, surfactants, proteins, and bacterial and viral pathogens. In this perspective, we discuss PT-target analyte complexation for bioanalytical applications and highlight recent advancements in point-of-care and field deployable assays. Subsequently, we highlight a few areas of critical importance for future applications of PTs as reporters, including (i) design and synthesis of specific PTs to advance the understanding of the mechanisms of interaction with target analytes, (ii) using arrays of PTs and linear discriminant analysis for selective and specific detection of target analytes, (iii) translation of conventional homogeneous solution-based assays into heterogeneous membrane-based assay formats, and finally (iv) the potential of using PT as an alternative to conjugated polymer nanoparticles and dots in bioimaging.Article Citation - WoS: 40Citation - Scopus: 41Colorimetric Urinalysis for On-Site Detection of Metabolic Biomarkers(American Chemical Society, 2020) Yeasmin, Sanjida; Ammanath, Gopal; Ali, Yusuf; Boehm, Bernhard O.; Yıldız, Ümit Hakan; Palaniappan, Alagappan; Liedberg, BoOver the past few decades, colorimetric assays have been developed for cost-effective and rapid on-site urinalysis. Most of these assays were employed for detection of biomarkers such as glucose, uric acid, ions, and albumin that are abundant in urine at micromolar to millimolar levels. In contrast, direct assaying of urinary biomarkers such as glycated proteins, low-molecular-weight reactive oxygen species, and nucleic acids that are present at significantly lower levels (nanomolar to picomolar) remain challenging due to the interferences from the urine sample matrix. State-of-the-art assays for detection of trace amounts of urinary biomarkers typically utilize time-consuming and equipment-dependent sample pretreatment or clean-up protocols prior to assaying, which limits their applicability for on-site analysis. Herein, we report a colorimetric assay for on-site detection of trace amount of generic biomarkers in urine without involving tedious sample pretreatment protocols. The detection strategy is based on monitoring the changes in optical properties of poly(3-(4-methyl-3'-thienyloxy)propyltriethylammonium bromide) upon interacting with an aptamer or a peptide nucleic acid in the presence and absence of target biomarkers of relevance for the diagnosis of metabolic complications and diabetes. As a proof of concept, this study demonstrates facile assaying of advanced glycation end products, 8-hydroxy-2'-deoxyguanosine and hepatitis B virus DNA in urine samples at clinically relevant concentrations, with limits of detection of similar to 850 pM, similar to 650 pM, and similar to 1 nM, respectively. These analytes represent three distinct classes of biomarkers: (i) glycated proteins, (ii) low-molecular-weight reactive oxygen species, and (iii) nucleic acids. Hence, the proposed methodology is applicable for rapid detection of generic biomarkers in urine, without involving sophisticated equipment and skilled personnel, thereby enabling on-site urinalysis. At the end of the contribution, we discuss the opportunity to translate the homogeneous assay into a paper-based format.Article Citation - WoS: 13Citation - Scopus: 13Single Chain Cationic Polymer Dot as a Fluorescent Probe for Cell Imaging and Selective Determination of Hepatocellular Carcinoma Cells(American Chemical Society, 2019) Özenler, Sezer; Yücel, Müge; Tüncel, Özge; Kaya, Hakan; Özçelik, Serdar; Yıldız, Ümit HakanThis letter describes formation of single chain cationic polymer dots (Pdots) made of poly[1,4-dimethy1-1-(34(2,4,5-trimethylthiophen-3-yl)oxy)propyl)piperazin-1-ium bromide] conjugated polyelectrolyte (CPE). The single chain Pdot formation relies on a simple process which is a rapid nanophase separation between CPE solution of ethylene glycol and water. Pdots show narrow monodisperse size distribution with a 3.6 nm in diameter exhibiting high brightness and excellent colloidal and optical stability. It has been demonstrated that photoluminescent Pdots provide selective nuclear translocation to hepatocellular carcinoma cells as compared to healthy liver cells. The Pdot labeling effectively discriminates cancer cells in the coculture media. Pdots hold great promise as a luminescent probe to diagnose cancer cells in histology and may guide surgeons during operations to precisely separate out cancerous tissue due to augmented fluorescence brightness.Article Citation - WoS: 7Citation - Scopus: 7Fabrication of a Postfunctionalizable, Biorepellent, Electroactive Polyurethane Interface on a Gold Surface by Surface-Assisted Polymerization(American Chemical Society, 2020) Özenler, Sezer; Sözen, Yiğit; Şahin, Hasan; Yıldız, Ümit HakanThis study describes surface-assisted (SurfAst) urethane polymerization, providing a modular/postfunctionalizable, biorepellent, electroactive similar to 10 to 100 nm-thick polyurethane (PU) interface on a gold surface. SurfAst is a functionalization methodology based on sequential incubation steps of alkane diisocyanates and alkanediol monomers. The gold surface is functionalized by alkane diisocyanates in the first incubation step, and our theoretical calculations reveal that while the isocyanate group atoms (N, C, and O) at one end of the molecule exhibits strong interactions (similar to 900 meV) with surface atoms, the other end group remains unreacted. After the first incubation step, sequential alkanediol and alkane diisocyanate incubations provide formation of the PU interface. The extensive analysis of the PU interface has been conducted via X-ray photoelectron spectroscopy, and the chemical mapping verifies that the interface is made of PU moieties. The topographical analysis of the surface conducted by the atomic force microscopy shows that the PU interface consists of mostly a nanoporous texture with 150 nm total roughness. The adherence force mapping of the PU interface reveals that the nanoporous matrix exhibits an adhesion force of about 14 nN. The electrostatic force microscopy characterizing long-range electrostatic interactions (40 nm) shows that the PU interface has been attracted by positively charged species as compared to negative objects. Finally, it is demonstrated that the PU interface is readily postfunctionalizable by polyethylene glycol (PEG 1000), serving as a biorepellent interface and preserving electroactivity. We foresee that SurfAst polymerization will have potential for the facile fabrication of a postfunctionalizable and modular biointerface which might be utilized for biosensing and bioelectronic applications.Article Citation - WoS: 18Citation - Scopus: 19Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers(American Chemical Society, 2018) Yücel, Müge; Akın, Osman; Çayören, Mehmet; Akduman, İbrahim; Palaniappan, Alagappan; Liedberg, Bo; Hızal, Gürkan; İnci, Fatih; Yıldız, Ümit HakanThis study reports on a hand-held volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multiwalled carbon nanotube (MWCNT) sensing microchannels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits a stable response to interferences of humidity and CO2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing microchannels "P1" (PVDF-MWCNT), "P2" (PS-MWCNT), and "P3" (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing microchannels upon exposure to breath in the concentration ranges between 35 ppb and 3.0 ppm for acetone and 1 ppb and 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.Article Citation - WoS: 32Citation - Scopus: 32Luminescent Device for the Detection of Oxidative Stress Biomarkers in Artificial Urine(American Chemical Society, 2018) Ammanath, Gopal; Yıldız, Ümit Hakan; Palaniappan, Alagappan; Liedberg, BoA luminescent paper-based device for the visual detection of oxidative stress biomarkers is reported. The device consists of a polyvinylidene fluoride membrane impregnated with poly(3-alkoxy-4-methylthiophene) (PT) for colorimetric detection. 8-hydroxy-2′-deoxyguanosine (8-OHdG), a biomarker associated with oxidative stress, is used as a model system for validating the proposed methodology. The detection strategy is based on monitoring the changes in optical properties of PT associated with its conformational changes upon interaction with an aptamer in the presence and in the absence of 8-OHdG. Fluorometric and colorimetric monitoring revealed linear responses for 8-OHdG concentrations between 50 pM and 500 nM (∼14 pg/mL to 140 ng/mL), with limits of detection of ∼300 pM and ∼350 pM, respectively for (n = 3). Colorimetric responses in artificial urine ascertained rapid, sensitive, and selective detection of 8-OHdG at clinically relevant (pM to nM) concentration levels. Furthermore, the proposed methodology enables point-of-care diagnostics for oxidative stress without requiring sophisticated instrumentation.Article Citation - WoS: 24Citation - Scopus: 23Tailoring Conformation-Induced Chromism of Polythiophene Copolymers for Nucleic Acid Assay at Resource Limited Settings(American Chemical Society, 2016) Rajwar, Deepa; Ammanath, Gopal; Cheema, Jamal Ahmed; Palaniappan, Alagappan; Yıldız, Ümit Hakan; Liedberg, BoHere we report on the design and synthesis of cationic water-soluble thiophene copolymers as reporters for colorimetric detection of microRNA (miRNA) in human plasma. Poly(3-alkoxythiophene) (PT) polyelectrolytes with controlled ratios of pendant groups such as triethylamine/1-methyl imidazole were synthesized for optimizing interaction with target miRNA sequence (Tseq). Incorporation of specific peptide nucleic acid (PNA) sequences with the cationic polythiophenes yielded distinguishable responses upon formation of fluorescent PT-PNA-Tseq triplex and weakly fluorescent PT-Tseq duplex, thereby enabling selective detection of target miRNA. Unlike homopolymers of PT (hPT), experimental results indicate the possibility of utilizing copolymers of PT (cPT) with appropriate ratios of pendant groups for miRNA assay in complex matrices such as plasma. As an illustration, colorimetric responses were obtained for lung cancer associated miRNA sequence (mir21) in human plasma, with a detection limit of 10 nM, illustrating the feasibility of proposed methodology for clinical applications without involving sophisticated instrumentation. The described methodology therefore possesses high potential for low-cost nucleic acid assays in resource-limited settings.
