WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7150

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 2
    Citation - Scopus: 1
    Errors Associated With Swelling in the Analysis of Polymer-Solvent Diffusion Measurements
    (Elsevier Ltd., 2005) Alsoy Altınkaya, Sacide
    Sorption curves are generated from a mathematical model which includes the influence of the polymer swelling for unsteady-state sorption of a vapor or liquid by a polymer. To investigate the simultaneous effects of the specific volumes of the polymer-penetrant pair and the difference between the final and initial equilibrium concentrations on the sorption curves, statistical experimental design approach is used. Simulation results obtained from the numerical solution of model equations are utilized to estimate the error that would occur if one simply evaluates the diffusion coefficient using the traditional formulas derived from the analytical solution of the sorption equation. An empirical expression is developed that describes the effects of the difference between the final and initial equilibrium concentrations and the specific volumes of the polymer and the penetrant on the magnitude of error in diffusivity associated with the use of one of these traditional formulas so called the initial slope method. The predictive ability of the regression model is tested by performing additional simulations not used in the regression analysis.
  • Article
    Citation - WoS: 28
    Citation - Scopus: 28
    Speciation and Preconcentration of Inorganic Antimony in Waters by Duolite Gt-73 Microcolumn and Determination by Segmented Flow Injection-Hydride Generation Atomic Absorption Spectrometry (sfi-Hgaas)
    (Elsevier Ltd., 2005) Erdem, Aslı; Eroğlu, Ahmet Emin
    A selective matrix removal/separation/enrichment method, utilizing a microcolumn of a chelating resin with SH functional groups (Duolite GT-73), was proposed for the determination of Sb(III) in waters by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). The resin was selective to Sb(III) at almost all pH and acidity values employed, whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with l-cysteine. Spike recoveries were tested at various concentration levels in different water types and were found to vary between 85 and 118%. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined (13.3 ± 1.1 μg l-1) and the certified value (13.79 ± 0.42 μg l-1). The method was applied to several bottled drinking water samples for antimony determination with and without preconcentration and none of the samples were found to contain antimony above the permissible level (5 μg l-1). The characteristic concentration (the concentration of the analyte corresponding to an absorbance of 0.0044) was 0.55 μg l-1 and the 3 s limit of detection (LOD) based on five times preconcentration was 0.06 μg l-1. The applicability of the microcolumn separation/preconcentration/matrix removal method for flow injection systems was also demonstrated.