Speciation and Preconcentration of Inorganic Antimony in Waters by Duolite Gt-73 Microcolumn and Determination by Segmented Flow Injection-Hydride Generation Atomic Absorption Spectrometry (sfi-Hgaas)
Loading...
Files
Date
Authors
Eroğlu, Ahmet Emin
Journal Title
Journal ISSN
Volume Title
Publisher
Open Access Color
BRONZE
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
A selective matrix removal/separation/enrichment method, utilizing a microcolumn of a chelating resin with SH functional groups (Duolite GT-73), was proposed for the determination of Sb(III) in waters by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). The resin was selective to Sb(III) at almost all pH and acidity values employed, whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with l-cysteine. Spike recoveries were tested at various concentration levels in different water types and were found to vary between 85 and 118%. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined (13.3 ± 1.1 μg l-1) and the certified value (13.79 ± 0.42 μg l-1). The method was applied to several bottled drinking water samples for antimony determination with and without preconcentration and none of the samples were found to contain antimony above the permissible level (5 μg l-1). The characteristic concentration (the concentration of the analyte corresponding to an absorbance of 0.0044) was 0.55 μg l-1 and the 3 s limit of detection (LOD) based on five times preconcentration was 0.06 μg l-1. The applicability of the microcolumn separation/preconcentration/matrix removal method for flow injection systems was also demonstrated.
Description
Keywords
Absorption, Duolite GT-73, Microcolumn, Antimony compounds, Duolite GT-73, Antimony compounds, Absorption, Microcolumn
Fields of Science
01 natural sciences, 0104 chemical sciences
Citation
Erdem, A.,and Eroğlu, A. E. (2005). Speciation and preconcentration of inorganic antimony in waters by Duolite GT-73 microcolumn and determination by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). Talanta, 68(1), 86-92. doi:10.1016/j.talanta.2005.04.041
WoS Q
Scopus Q

OpenCitations Citation Count
25
Source
Volume
68
Issue
1
Start Page
86
End Page
92
PlumX Metrics
Citations
CrossRef : 21
Scopus : 28
PubMed : 1
Captures
Mendeley Readers : 16
SCOPUS™ Citations
28
checked on Apr 28, 2026
Web of Science™ Citations
28
checked on Apr 28, 2026
Page Views
732
checked on Apr 28, 2026
Downloads
1111
checked on Apr 28, 2026
Google Scholar™