WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
Search Results
Now showing 1 - 10 of 15
Article Citation - WoS: 44Citation - Scopus: 88Performance and Operation of the Cms Electromagnetic Calorimeter(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.Article Citation - WoS: 33Citation - Scopus: 44CMS Data Processing Workflows During an Extended Cosmic Ray Run(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data. © 2010 IOP Publishing Ltd and SISSA.Article Citation - WoS: 33Citation - Scopus: 44Aligning the Cms Muon Chambers With the Muon Alignment System During an Extended Cosmic Ray Run(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.Article Citation - WoS: 35Citation - Scopus: 43Commissioning of the Cms High-Level Trigger With Cosmic Rays(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe CMS High-Level Trigger (HLT) is responsible for ensuring that data samples with potentially interesting events are recorded with high efficiency and good quality. This paper gives an overview of the HLT and focuses on its commissioning using cosmic rays. The selection of triggers that were deployed is presented and the online grouping of triggered events into streams and primary datasets is discussed. Tools for online and offline data quality monitoring for the HLT are described, and the operational performance of the muon HLT algorithms is reviewed. The average time taken for the HLT selection and its dependence on detector and operating conditions are presented. The HLT performed reliably and helped provide a large dataset. This dataset has proven to be invaluable for understanding the performance of the trigger and the CMS experiment as a whole. © 2010 IOP Publishing Ltd and SISSA.Article Citation - WoS: 54Citation - Scopus: 49Performance of the Cms Hadron Calorimeter With Cosmic Ray Muons and Lhc Beam Data(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked. © 2010 IOP Publishing Ltd and SISSA.Article Citation - WoS: 37Citation - Scopus: 41Performance of the Cms Cathode Strip Chambers With Cosmic Rays(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.Article Citation - WoS: 60Citation - Scopus: 41Commissioning and Performance of the Cms Pixel Tracker With Cosmic Ray Muons(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns. © 2010 IOP Publishing Ltd and SISSA.Article Citation - WoS: 37Citation - Scopus: 55Performance Study of the Cms Barrel Resistive Plate Chambers With Cosmic Rays(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerIn October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.Article Citation - WoS: 5Citation - Scopus: 31Performance of the Cms Drift Tube Chambers With Cosmic Rays(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerStudies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector.Article Citation - WoS: 37Citation - Scopus: 52Performance of the Cms Level-1 Trigger During Commissioning With Cosmic Ray Muons and Lhc Beams(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected.
