Abstract
The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked. © 2010 IOP Publishing Ltd and SISSA.
Description
Keywords
Calorimeters, Large detector systems, Compact Muon Solenoid, Large Hadron Collider (LHC), Cosmic Run At Four Tesla (CRAFT), MAGNETIC-FIELDS; CALIBRATION; SCINTILLATORS; DESIGN; WEDGES, CMS experiment, Design, Compact Muon Solenoid, Physics - Instrumentation and Detectors, 610, FOS: Physical sciences, Large Hadron Collider (LHC), 530, MAGNETIC-FIELDS, PARTICLE PHYSICS; LARGE HADRON COLLIDER; CMS, Calorimeters, DESIGN, cosmic muons, SCINTILLATORS, Large detector systems, [PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det], info:eu-repo/classification/ddc/530, info:eu-repo/classification/ddc/610, CALIBRATION, hadron calorimeter, Calorimeter, Calorimeters; Large detector systems for particle and astroparticle physics, Wedges, CMS, Large detector systems for particle and astroparticle physics, Physics, ddc:530, Instrumentation and Detectors (physics.ins-det), LARGE HADRON COLLIDER, Cosmic Run At Four Tesla (CRAFT), WEDGES, Magnetic-fields, [PHYS.PHYS.PHYS-INS-DET] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det], Scintillators, Calibration, CMS; LHC; cosmic muons; hadron calorimeter, Large detector system, Particle and astroparticle physic, Instrumentation; Mathematical Physics, PARTICLE PHYSICS, LHC
Fields of Science
03 medical and health sciences, 0302 clinical medicine
Citation
Chatrchyan, S., Khachatryan, V., Sirunyan, A. M., Adam. W., Arnold, B., ...CMS Collaboration (2010). Performance of the CMS hadron calorimeter with cosmic ray muons and LHC beam data. Journal of Instrumentation, 5(3). doi:10.1088/1748-0221/5/03/T03012
WoS Q
Scopus Q

OpenCitations Citation Count
19
Volume
5
Issue
3
Start Page
End Page
PlumX Metrics
Citations
CrossRef : 14
Captures
Mendeley Readers : 227
SCOPUS™ Citations
49
checked on Apr 29, 2026
Web of Science™ Citations
54
checked on Apr 29, 2026
Page Views
721
checked on Apr 29, 2026
Downloads
301
checked on Apr 29, 2026
Google Scholar™