Energy Systems Engineering / Enerji Sistemleri Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4752

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 33
    Citation - Scopus: 42
    Thermodynamic Assessment of Downhole Heat Exchangers for Geothermal Power Generation
    (Elsevier, 2019) Yıldırım, Nurdan; Parmanto, Slamet; Akkurt, Gülden Gökçen
    Downhole heat exchanger is a device to extract heat from geothermal fluid. While it is widely used for heating purposes, its use for power generation has not been reported. The aim of this study is to examine the feasibility of power generation from a 2500 m deep existing geothermal well with high temperature gradient and insufficient flowrate by using a downhole heat exchanger. For this purpose, a thermodynamic and an economic evaluation model are developed by the use of Engineering Equation Solver software. Additionally, the parametric studies have been carried out to identify the effects of insulation, geothermal well conditions, geometry of downhole heat exchanger, mass flowrate and type of working fluids on the performance of downhole heat exchanger system. Consequently, work output of the best alternative is computed as 2511 kW(e) with 64 kg/s mass flowrate of R-134a for 2500 m-deep downhole heat exchanger having inner pipe diameter of 0.127 m. Electricity generation cost and simple payback time are calculated as 46 $/MWh and 2.25 years, respectively. The obtained results showed that the downhole heat exchanger system can be a feasible alternative for wells with very low geothermal flowrate to generate power. (C) 2019 Elsevier Ltd. All rights reserved.
  • Book Part
    Citation - Scopus: 11
    Thermodynamic Performance Evaluation of a Geothermal Drying System
    (Springer Verlag, 2014) Helvacı, Hüseyin Utku; Gökçen Akkurt, Gülden
    Renewable energy sources such as geothermal energy can be used in drying processes as a heat source due to the high energy costs of fossil fuels. In this study, geothermal cabinet type dryer was constructed and situated in Balcova-Narlidere Geothermal Field, Turkey where the clean city water of district heating system is used as an energy source for the dryer. The dryer was tested on site for drying of olive leaves and energy and exergy analyses of the drying process conducted under two cases: Case 1. Exhaust air was rejected to the environment. Case 2. A portion of exhaust air was re-circulated. Energy Utilization Ratio (EUR) was determined as 7.96 for Case 1 and 50.36 for Case 2. The highest rate of exergy destruction occurred in the fan, followed by heat exchanger and the dryer, accounting for 0.2913, 0.05663 and 0.0115 kW, respectively. Exergetic efficiency of the drying chamber was calculated as 89.66 %. Re-circulating the exhaust air decreased the exergy value at the outlet of the dryer from 0.1013 to 0.08104 kW, indicating that re-using the air increases the performance of the dyer.