Chemistry / Kimya
Permanent URI for this collectionhttps://hdl.handle.net/11147/4072
Browse
49 results
Search Results
Article Citation - WoS: 169Citation - Scopus: 177Thin Film Microextraction: Towards Faster and More Sensitive Microextraction(Elsevier Ltd., 2019) Ölçer, Yekta Arya; Tascon, Marcos; Eroğlu, Ahmet Emin; Boyacı, EzelThin film microextraction (TFME) is an analytical tool that has been proven to be suitable for integrated sampling and sample preparation of a wide variety of routine and on-site applications. Compared to the traditional microextraction techniques, the most important advantage of TFME is its enhanced sensitivity due to the relatively larger extractive phase spread over a larger surface area. The technique, in this way, facilitates fast extraction kinetics and high extractive capacity. Moreover, TFME offers high versatility for device development over classical SPME technologies due to the plethora of available extractive phases, coating methods and geometry options. The goal of this review is to provide a comprehensive summary of the contemporary advances in this exciting field covering novel extractive phases, technological and methodological developments, and relevant cutting-edge applications. Finally, a critical discussion of the future trends on TFME is also presented. (C) 2019 Elsevier B.V. All rights reserved.Article Citation - WoS: 8Citation - Scopus: 10Trypsin-Immobilized Silica: a Novel Adsorbent for V(iv) and V(v) Removal From Water(Water Environment Federation, 2018) Erdem Yayayürük, Aslı; Shahwan, Talal; Şanlı Mohamed, Gülşah; Eroğlu, Ahmet EminIn the present study, trypsin-immobilized silica was employed for the removal of V(IV) and V(V) ions from water. The synthesized sorbent was first characterized and then investigated for the removal of V(IV) and V(V) under various experimental conditions. The adsorption performance of the sorbent was tested as a function of pli, sorbent amount, initial vanadium concentration, contact time, and temperature. The sorption process was then investigated, both from a kinetic perspective and also in terms of isotherm models. The Langmuir adsorption isotherm was the best model to describe the sorption process. Sorption thermodynamics were spontaneous and exothermic. The proposed method was successfully applied to real samples for the removal of V(IV)and V(V) with sufficient accuracy and precision.Article Citation - WoS: 45Citation - Scopus: 46Electrospun Polystyrene Fibers Knitted Around Imprinted Acrylate Microspheres as Sorbent for Paraben Derivatives(Elsevier, 2018) Demirkurt, Merve; Ölçer, Yekta Arya; Demir, Mustafa Muammer; Eroğlu, Ahmet EroğluParabens are used as antimicrobial preservatives in food, cosmetic products and pharmaceuticals regardless of their endocrine disrupting effect. In this study, highly selective molecular imprinted polymers (MIPs) were synthesized in submicron-sizes and converted to an SPME fiber coating through electrospinning process in order to determine parabens in water samples. Conversion of MIP to a fiber is achieved via creation of spacial knitting around MIP by polystyrene. The selectivity and extraction ability of the fibers were compared with the commercial fibers and the corresponding non-imprinted polymer (NIP) coated fiber. The coated fiber showed better extraction ability among them. Also, the results revealed that the fiber has better selectivity for benzyl paraben and the other structurally-related compounds, such as methyl and propyl paraben. Extraction efficiency of prepared fibers for three parabens has been tested by spiking bottled, tap and sea water samples. The recoveries changed between 92.2 ± 0.8 and 99.8 ± 0.1 for three different water types. This method could be used for selective and sensitive determination of parabens in aqueous samples.Article Citation - WoS: 1Citation - Scopus: 1Amalgamation Performances of Gold-Coated Quartz Wool, Alumina, Silica, Sand and Carbon Fiber for the Determination of Inorganic Mercury in Waters by Cold Vapor Atomic Absorption Spectrometry(Pleiades Publishing, 2017) Erdem Şimşek, Arzu; Erdem Yayayürük, Aslı; Shahwan, Talal; Eroğlu, Ahmet EminDifferent gold-coated sorbents for amalgamation were applied for the determination of inorganic mercury in waters using a home-made cold vapor generation unit coupled to atomic absorption spectrometry. Among the gold-coated materials investigated (quartz wool, alumina, silica, sand and carbon fiber) quartz wool was found to give the most efficient results in terms of sorption and release. Analytical performance of the system without and with amalgamation was investigated and it was found that when amalgamation was applied, the linearity and slope of the calibration plots were independent on the sample volume for 1.0, 5.0 and 10.0 mL. Method validation was realized through the analysis of a sample of spring water spiked with 1.0 μg/L inorganic mercury and the spike recoveries were found to be 95 ± 1, 91 ± 3, and 99 ± 5% for 1.0, 5.0, and 10.0 mL, respectively. The results demonstrated that the methodology can be applied to these types of samples directly or after amalgamation, depending on the mercury concentration.Article Citation - WoS: 55Citation - Scopus: 60Development of Molecularly Imprinted Polymers (mips) as a Solid Phase Extraction (spe) Sorbent for the Determination of Ibuprofen in Water(Royal Society of Chemistry, 2017) Ölçer, Yekta Arya; Demirkurt, Merve; Demir, Mustafa Muammer; Eroğlu, Ahmet EminIbuprofen is a well-known endocrine disrupter. In this study, highly selective molecularly imprinted polymers (MIPs) with different morphologies were synthesized via precipitation and bulk polymerization of methacrylic acid (MAA) and trimethylolpropane trimethacrylate (TRIM) in the presence of ibuprofen as a template. Non-imprinted polymers (NIPs) were also synthesized via the same procedure in the absence of ibuprofen. Spherical and monolithic MIPs were obtained using different experimental conditions, and the spherical MIP was shown to have better sorption towards ibuprofen. The optimum sample pH, sorbent amount, sample volume, and sorption time were determined to be 8.0, 25.0 mg, 10.0 mL, and 30.0 min, respectively. A methanol water mixture (MeOH:H2O, 80:20, pH 3.0) was employed as an eluent with >97% (±0.8, n = 3) desorption. The MIP demonstrated high selectivity towards ibuprofen in the presence of naproxen and ketoprofen. The validity of the proposed method was checked via spike recovery tests using drinking and tap water samples. The method worked efficiently for both water types, resulting in the recoveries of 97.2% (±0.3, n = 3) and 97.7% (±0.2, n = 3).Article Citation - WoS: 5Citation - Scopus: 5Use of Amberlite Xad-7hp for the Separation of Mn(ii) and Mn(vii) in Waters(Pleiades Publishing, 2017) Erdem Yayayürük, Aslı; Eroğlu, Ahmet EminA simple method is proposed for the determination and speciation of Mn(II) and Mn(VII) in waters utilizing a macroporous resin, Amberlite XAD-7HP. The batch method was employed and flame atomic absorption spectrometry was used in all determinations. Amberlite XAD-7HP resin was shown to retain Mn(VII) between pH 4 and 12. If the solution contains only one of the species, either Mn(II) or Mn(VII), the resin behaves selectively depending on the pH of the solution. The elution from the sorbent was realized using K2C2O4 in HNO3. The efficiency of the method was checked via spike recovery experiments. The proposed method was successfully applied to industrial wastewater samples and quantitative recoveries (≥96.0%) confirmed the accuracy of the method.Article Citation - WoS: 12Citation - Scopus: 16Carotenoid Profile in Prochlorococcus Sp. and Enrichment of Lutein Using Different Nitrogen Sources(Springer Verlag, 2016) Erdoğan, Ayşegül; Demirel, Zeliha; Eroğlu, Ahmet Emin; Conk Dalay, MeltemVarious carotenoids of the cyanobacterium Prochlorococcus sp. are identified using chromatographic/spectroscopic techniques and quantified using HPLC-DAD. In the present study, β-apo-8′-carotenal was used as internal standard. Identification of carotenoids was carried out by comparing the retention time, absorption spectra, and mass spectra of unknown peaks with reference standards. All-trans-lutein was found to be the major carotenoid in this cyanobacterium, and, therefore, algal productivity and the potential for lutein accumulation were analyzed as a function of different nitrogen sources such as nitrate, nitrite, ammonia, and urea for cultivation. Among them, urea clearly led to the best lutein accumulation. According to the experimental evidence, lutein increased from 2.54 to 3.34 mg g−1 in the cyanobacteria when urea was used as the nitrogen source. © 2016, Springer Science+Business Media Dordrecht.Article Citation - WoS: 8Hydrogen Sulfide Determination by Solid Surface Luminescence(Springer Verlag, 1996) Eroğlu, Ahmet Emin; Volkan, Mürvet; Bayramlı, Erdal; Ataman, O. Yavuz; Mark, Harry B.In the analytical system suggested, atmospheric hydrogen sulfide reacts with the surface of a filter paper treated with aqueous cadmium chloride and yields a luminescent species whose intensity can be correlated with the analyte concentration in ambient air. It was shown that the luminescent species are CdS solid particles which were formed in a well defined size. The paper luminescence was also tried on polymeric surfaces; polyethyleneoxide, polyvinyl alcohol, ethylcellulose and carboxymethylcellulose were found to give a similar luminescence signal. The system can be used on the tip of an optical fiber for an irreversible, cumulative type of analytical device for hydrogen sulfide determination. The 3s detection limit for the paper luminescence detection system was 7.8 ppb H2S.Article Citation - WoS: 7Citation - Scopus: 8Evaluation of Dissolution Methods in the Presence of High Chloride Content for the Determination of Germanium in Geological Matrices by Hydride Generation Atomic Absorption Spectrometry(Japan Society for Analytical Chemistry, 2001) Abbasi, Husam U.; Eroğlu, Ahmet Emin; Anwari, Mohammad A.; Volkan, MürvetThe sample dissolution is probably the most crucial step in the determination of germanium in geological and metallurgical samples due to formation of volatile germanium compounds during the course of dissolution. It has been stated that this is especially true for the samples having high sulfide and/or chloride content.Article Citation - WoS: 6Citation - Scopus: 8Growth and Uptake of Sodium and Potassium in Broad Bean (vicia Faba L.) Under Salinity Stress(Taylor and Francis Ltd., 2011) Bulut, Fatma; Akıncı, Şener; Eroğlu, Ahmet EminVicia faba L. (broad bean or faba bean), a food crop of worldwide importance, is moderately tolerant of saline conditions, such as are increasingly common in Mediterranean countries and in Turkey. Our objective was to determine the influence of two salinity levels [50 and 100 mM sodium chloride (NaCl)] and two potassium salts, potassium nitrate (KNO3) (N1 and N2) or potassium acetate (CH3COOK) (A1 and A2), on the development of seedlings of two cultivars of broad bean (cvs. Eresen 87 and Filiz 99) grown in pots of perlite under controlled greenhouse conditions. Flame photometer (FP) analysis of tissues from roots, stems, and leaves of 3-month-old seedlings showed significant differences in growth, internodal length, and potassium (K+)/sodium (Na+) ratios. The FP analyses revealed that Na+ was the ion most responsible for inhibition of growth parameters seen in both cultivars and salt treatments. K+ contents were consistently higher in cv. Filiz 99 than in cv. Eresen 87. Possible correlations between these data and the tolerance to salinity of these cultivars are discussed.
