Bioengineering / Biyomühendislik

Permanent URI for this collectionhttps://hdl.handle.net/11147/4529

Browse

Search Results

Now showing 1 - 6 of 6
  • Article
    Citation - WoS: 1
    Citation - Scopus: 1
    The Soft Nanodots as Fluorescent Probes for Cell Imaging: Analysis of Cell and Spheroid Penetration Behavior of Single Chain Polymer Dots
    (Wiley, 2024) Yücel, Müge; Onbaş, Rabia; Arslan Yıldız, Ahu; Yıldız, Ümit Hakan
    This study describes the formation, size control, and penetration behavior of polymer nanodots (Pdots) consisting of single or few chain polythiophene-based conjugated polyelectrolytes (CPEs) via nanophase separation between good solvent and poor solvent of CPE. Though the chain singularity may be associated with dilution nanophase separation suggests that molecules of a good solvent create a thermodynamically driven solvation layer surrounding the CPEs and thereby separating the single chains even in their poor solvents. This statement is therefore corroborated with emission intensity/lifetime, particle size, and scattering intensity of polyelectrolyte in good and poor solvents. Regarding the augmented features, Pdots are implemented into cell imaging studies to understand the nuclear penetration and to differentiate the invasive characteristics of breast cancer cells. The python based red, green, blue (RGB) color analysis depicts that Pdots have more nuclear penetration ability in triple negative breast cancer cells due to the different nuclear morphology in shape and composition and Pdots have penetrated cell membrane as well as extracellular matrix in spheroid models. The current Pdot protocol and its utilization in cancer cell imaging are holding great promise for gene/drug delivery to target cancer cells by explicitly achieving the very first priority of nuclear intake. The penetration capability of cationic soft nanodots in to tumor models of breast cancer is demonstrated. The image analysis based on fluorescence intensity variation reveals the characteristics of translocation of nanodots in dense mediums such as tumor models.image
  • Article
    Citation - WoS: 43
    Citation - Scopus: 46
    Glucuronoxylan-Based Quince Seed Hydrogel: a Promising Scaffold for Tissue Engineering Applications
    (Elsevier, 2021) Güzelgülgen, Meltem; Özkendir İnanç, Dilce; Yıldız, Ümit Hakan; Arslan Yıldız, Ahu
    Natural gums and mucilages from plant-derived polysaccharides are potential candidates for a tissue-engineering scaffold by their ability of gelation and biocompatibility. Herein, we utilized Glucuron-oxylanbased quince seed hydrogel (QSH) as a scaffold for tissue engineering applications. Optimization of QSH gelation was conducted by varying QSH and crosslinker glutaraldehyde (GTA) concentrations. Structural characterization of QSH was done by Fourier Transform Infrared Spectroscopy (MR). Furthermore, morphological and mechanical investigation of QSH was performed by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The protein adsorption test revealed the suitability of QSH for cell attachment. Biocompatibility of QSH was confirmed by culturing NIH-3T3 mouse fibroblast cells on it. Cell viability and proliferation results revealed that optimum parameters for cell viability were 2 mg mi(-1)of QSH and 0.03 M GTA. SEM and DAPI staining results indicated the formation of spheroids with a diameter of approximately 300 pm. Furthermore, formation of extracellular matrix (ECM) microenvironment was confirmed with the Collagen Type-I staining. Here, it was demonstrated that the fabricated QSH is a promising scaffold for 3D cell culture and tissue engineering applications provided by its highly porous structure, remarkable swelling capacity and high biocompatibility. (C) 2021 Published by Elsevier B.V.
  • Article
    Citation - WoS: 13
    Citation - Scopus: 13
    Single Chain Cationic Polymer Dot as a Fluorescent Probe for Cell Imaging and Selective Determination of Hepatocellular Carcinoma Cells
    (American Chemical Society, 2019) Özenler, Sezer; Yücel, Müge; Tüncel, Özge; Kaya, Hakan; Özçelik, Serdar; Yıldız, Ümit Hakan
    This letter describes formation of single chain cationic polymer dots (Pdots) made of poly[1,4-dimethy1-1-(34(2,4,5-trimethylthiophen-3-yl)oxy)propyl)piperazin-1-ium bromide] conjugated polyelectrolyte (CPE). The single chain Pdot formation relies on a simple process which is a rapid nanophase separation between CPE solution of ethylene glycol and water. Pdots show narrow monodisperse size distribution with a 3.6 nm in diameter exhibiting high brightness and excellent colloidal and optical stability. It has been demonstrated that photoluminescent Pdots provide selective nuclear translocation to hepatocellular carcinoma cells as compared to healthy liver cells. The Pdot labeling effectively discriminates cancer cells in the coculture media. Pdots hold great promise as a luminescent probe to diagnose cancer cells in histology and may guide surgeons during operations to precisely separate out cancerous tissue due to augmented fluorescence brightness.
  • Article
    Citation - WoS: 34
    Citation - Scopus: 36
    Biomimetic Hybrid Scaffold Consisting of Co-Electrospun Collagen and Pllcl for 3d Cell Culture
    (Elsevier Ltd., 2019) Türker, Esra; Yıldız, Ümit Hakan; Arslan Yıldız, Ahu
    Electrospun collagen is commonly used as a scaffold in tissue engineering applications since it mimics the content and morphology of native extracellular matrix (ECM) well. This report describes "toxic solvent free" fabrication of electrospun hybrid scaffold consisting of Collagen (Col) and Poly(L-lactide-co-epsilon-caprolactone) (PLLCL) for three-dimensional (3D) cell culture. Biomimetic hybrid scaffold was fabricated via co-spinning approach where simultaneous electrospinning of PLLCL and Collagen was mediated by polymer sacrificing agent Polyvinylpyrrolidone (PVP). Acidified aqueous solution of PVP was used to solubilize collagen without using toxic solvents for electrospinning, and then PVP was readily removed by rinsing in water. Mechanical characterizations, protein adsorption, as well as biodegradation analysis have been conducted to investigate feasibility of biomimetic hybrid scaffold for 3D cell culture applications. Electrospun biomimetic hybrid scaffold, which has 3D-network structure with 300-450 nm fiber diameters, was found to be maximizing cell adhesion through assisting NIH 3T3 mouse fibroblast cells. 3D cell culture studies confirmed that presence of collagen in biomimetic hybrid scaffold have created a major impact on cell proliferation compared to conventional 2D systems on long-term, also cell viability increased with the increasing amount of collagen. (c) 2019 Elsevier B.V. All rights reserved.
  • Article
    Citation - WoS: 17
    Citation - Scopus: 19
    Pixelated Colorimetric Nucleic Acid Assay
    (Elsevier, 2020) Aydın, Hakan Berk; Cheema, Jamal Ahmed; Arnmanath, Gopal; Toklucu, Cihan; Yücel, Müge; Özenler, Sezer; Yıldız, Ümit Hakan
    Conjugated polyelectrolytes (CPEs) have been widely used as reporters in colorimetric assays targeting nucleic acids. CPEs provide naked eye detection possibility by their superior optical properties however, as concentration of target analytes decrease, trace amounts of nucleic acid typically yield colorimetric responses that are not readily perceivable by naked eye. Herein, we report a pixelated analysis approach for correlating colorimetric responses of CPE with nucleic acid concentrations down to 1 nM, in plasma samples, utilizing a smart phone with an algorithm that can perform analytical testing and data processing. The detection strategy employed relies on conformational transitions between single stranded nucleic acid-cationic CPE duplexes and double stranded nucleic acid-CPE triplexes that yield distinct colorimetric responses for enabling naked eye detection of nucleic acids. Cationic poly[N,N,N-triethyl-3-((4-methylthiophen-3-yl)oxy)propan-1-aminium bromide] is utilized as the CPE reporter deposited on a polyvinylidene fluoride (PVDF) membrane for nucleic acid assay. A smart phone application is developed to capture and digitize the colorimetric response of the individual pixels of the digital images of CPE on the PVDF membrane, followed by an analysis using the algorithm. The proposed pixelated approach enables precise quantification of nucleic acid assay concentrations, thereby eliminating the margin of error involved in conventional methodologies adopted for interpretation of colorimetric responses, for instance, RGB analysis. The obtained results illustrate that a ubiquitous smart phone could be utilized for point of care colorimetric nucleic acids assays in complex matrices without requiring sophisticated software or instrumentation.
  • Article
    Citation - WoS: 18
    Citation - Scopus: 19
    Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers
    (American Chemical Society, 2018) Yücel, Müge; Akın, Osman; Çayören, Mehmet; Akduman, İbrahim; Palaniappan, Alagappan; Liedberg, Bo; Hızal, Gürkan; İnci, Fatih; Yıldız, Ümit Hakan
    This study reports on a hand-held volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multiwalled carbon nanotube (MWCNT) sensing microchannels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits a stable response to interferences of humidity and CO2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing microchannels "P1" (PVDF-MWCNT), "P2" (PS-MWCNT), and "P3" (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing microchannels upon exposure to breath in the concentration ranges between 35 ppb and 3.0 ppm for acetone and 1 ppb and 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.