Architecture / Mimarlık

Permanent URI for this collectionhttps://hdl.handle.net/11147/24

Browse

Search Results

Now showing 1 - 5 of 5
  • Article
    Citation - WoS: 20
    Citation - Scopus: 17
    Optimizing Thermal Comfort in Physical Exercise Spaces: A Study of Spatial and Thermal Factors
    (Elsevier, 2024) Avcı, A.B.; Balci, G.A.; Başaran, T.
    Fitness centers have become famous for maintaining a healthy lifestyle. They require different thermal comfort conditions and higher fresh air supply rates than other indoor spaces. However, even well-designed centers may cause discomfort due to factors such as design decisions, ventilation, overheating, and overcrowding. The standards for fitness centers do not consider these specific requirements sufficiently, so this study focuses on understanding the thermal comfort requirements during physical exercise and evaluating spatial and thermal factors affecting the thermal environment around the body. The study investigated the ceiling height, lateral and frontal distances between machines, and vent locations as spatial factors and inlet temperature and air velocity as thermal factors. A thirty-minute moderate-intensity constant work rate exercise test was conducted in a controlled climatic chamber using a cycle ergometer with six healthy male participants. The experiment conditions were simulated in CFD software using the collected data. Once a validated simulation model was provided, computational models for different environmental and spatial scenarios for the five-person cycling class were generated. Using Taguchi L9 (34) orthogonal arrays method, nine spatial scenarios were simulated with three different thermal operations each. Optimal factor levels were determined by using thermal comfort conditions (based on predicted mean vote) around the body's thermal plume. The results showed that a ceiling height of 5 m, lateral and frontal distances of 1 m and 0.5 m between machines, and Type 2 (two inlets mounted on the ceiling) ventilation strategy were optimal for achieving better thermal comfort values in a thermal condition of 18 °C and 0.2 m·s−1. The study found that increasing the ceiling height and using cross-positioned vents that project air vertically from the ceiling improved the comfort conditions significantly. It is expected that these criteria, which were determined, compared with the standards and detailed, will contribute to the production processes of comfortable exercise spaces. © 2023 Elsevier B.V.
  • Article
    Citation - WoS: 10
    Citation - Scopus: 14
    Out-Of Seismic Performance of Bed-Joint Reinforced Autoclaved Aerated Concrete (aac) Infill Walls Damaged Under Cyclic In-Plane Displacement Reversals
    (Elsevier, 2023) Halıcı, Ömer Faruk; Demir, Uğur; Zabbar, Yassin; İlki, Alper
    The infill walls made of Autoclaved Aerated Concrete (AAC), which is a lightweight, fire resistant and energy efficient material, provide effective insulation solutions for building types of structures and becoming more and more popular in earthquake prone regions. Although the number of experimental tests examining the seismic response of clay brick infills is extensive, the amount of prior research on infill walls built of AAC blocks is rather limited. Past research revealed that the use of bed-joint reinforcement is one of the promising solutions to improve the global seismic response of masonry walls by enhancing strength and displacement capacity. In this study, the out-of-plane (OOP) seismic performance of AAC infill walls with flat-truss and innovative cord-type bed-joint reinforcement is experimentally evaluated. Also, consideration is given to the prior in-plane (IP) damage, which was found to degrade the seismic performance of infills in OOP direction. For this purpose, three IP and four OOP, in total, seven experimental tests were performed on four full-scale AAC infill wall specimens. The test parameters were selected in such a way as to make it possible to parametrically compare the OOP performance of AAC infills with flat-truss and cord-type bed-joint reinforcements with unreinforced AAC infill walls, together with the effect of prior IP damage on the OOP response of unreinforced AAC infill walls. It was found that the use of innovative cord-type bed-joint reinforcement improved the OOP strength to a similar extent to what was obtained from the truss-type reinforced specimen. In terms of ultimate displacement and energy dissipation capacity enhancement, the specimen with cord-type reinforcement performed better. In addition, the damages formed due to IP cyclic displacement reversals up to 0.005 drift ratio, which is defined as the drift limit for buildings with brittle infill walls in certain design codes, resulted in a significant reduction in the OOP strength and stiffness properties of AAC infills. The theoretical OOP strength calculations were found to provide unconservative strength values for the IP-damaged specimens.
  • Article
    Citation - WoS: 20
    Citation - Scopus: 23
    Thermal Comfort Analysis of Historical Mosques. Case Study: the Ulu Mosque, Manisa, Turkey
    (Elsevier, 2021) Diler, Yusuf; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden
    Mosques are sanctuary places for Muslims where they can perform their religious activities and also can communicate with each other. On the other hand, historical mosques may contain artworks which have cultural heritage values. These mosques originally have not any Heating, Ventilating and Air Conditioning systems. For this reason, obtaining thermal comfort becomes a significant issue. In this study, a systematic approach on monitoring and evaluating thermal comfort of historical mosques were developed. As a case study, The Ulu Mosque, Manisa/Turkey was monitored from 2015 to 2018, and thermal comfort evaluation of the mosque was conducted during prayer times based on the method provided by ISO 7730. A dynamic Building Energy Performance Software, DesignBuilder, was used to model the mosque, and the model was calibrated by using hourly indoor temperature data. The calibrated model was then used to evaluate existing conditions of the mosque and develop retrofitting scenarios in order to increase thermal comfort of prayers. Thirteen different scenarios were proposed to improve thermal comfort of prayers during worship periods. The results were evaluated according to EN 16883 for conservation of cultural heritage of the mosque. Electrical radiator heating with intermittent operating schedules was obtained as the best scenario to protect cultural heritage via artworks, while decreasing disssatisfaction level of the prayers from 45% to 10% in winter months. Additionally, intermittent operation saved 46.9% of energy compared to continuous operating schedule. (C) 2021 Elsevier B.V. All rights reserved.
  • Article
    Citation - WoS: 25
    Citation - Scopus: 28
    How To Learn To Be Creative in Design: Architecture Students' Perceptions of Design, Design Process, Design Learning, and Their Transformations Throughout Their Education
    (Elsevier, 2021) Taneri, Batuhan; Doğan, Fehmi
    The study explores students? perceptions of experiential learning, design and design process, and design education, and whether these perceptions vary according to school year students are in based on qualitative and quantitative data collected from two architectural schools. We inquire into how creativity and design could be learned through repeated design tasks without structured instructions about the creative design process. The explorative study employs surveys and semistructured focus group interviews. The results indicate problem-solving view of design is the most common characterization, students think design is not a straightforward problem solving and is most related to art and creativity. Finally, students report school has a limited impact on how they learn designing. We conclude experiential learning in the studio create shortcomings if not accompanied with a critical and reflective stance and that undertaking design tasks one after the other without explicit reflection on these tasks is an inefficient strategy in learning about the creative design process.
  • Article
    Citation - WoS: 27
    Citation - Scopus: 38
    Loose Coupling of Gis and Bim Data Models for Automated Compliance Checking Against Zoning Codes
    (Elsevier, 2021) Demir Altıntaş, Yelin; İlal, Mustafa Emre
    Modeling urban data is crucial for supporting automated code checking processes. Ideally, digitally modelled building codes and urban data should be retrieved from municipalities, and the digital building model should be checked automatically based on the collected information. However, BIM tools do not contain and do not allow managing geographical information at a neighborhood scale. Current GIS applications also do not store all of the information required by building codes. Even if they did, interoperability between GIS and BIM environments are problematic. This paper describes the development of a zoning domain model for automated compliance checking of building projects. The proposed model is illustrated through a proof-of-concept GIS application, where geometric and semantic data are stored, queried and exported as a GML file. Use of this data model for automated code checking is an example for how GIS data can seamlessly complement BIM data making expansion of BIM schemas unnecessary.