Architecture / Mimarlık
Permanent URI for this collectionhttps://hdl.handle.net/11147/24
Browse
8 results
Search Results
Article Citation - WoS: 20Citation - Scopus: 17Optimizing Thermal Comfort in Physical Exercise Spaces: A Study of Spatial and Thermal Factors(Elsevier, 2024) Avcı, A.B.; Balci, G.A.; Başaran, T.Fitness centers have become famous for maintaining a healthy lifestyle. They require different thermal comfort conditions and higher fresh air supply rates than other indoor spaces. However, even well-designed centers may cause discomfort due to factors such as design decisions, ventilation, overheating, and overcrowding. The standards for fitness centers do not consider these specific requirements sufficiently, so this study focuses on understanding the thermal comfort requirements during physical exercise and evaluating spatial and thermal factors affecting the thermal environment around the body. The study investigated the ceiling height, lateral and frontal distances between machines, and vent locations as spatial factors and inlet temperature and air velocity as thermal factors. A thirty-minute moderate-intensity constant work rate exercise test was conducted in a controlled climatic chamber using a cycle ergometer with six healthy male participants. The experiment conditions were simulated in CFD software using the collected data. Once a validated simulation model was provided, computational models for different environmental and spatial scenarios for the five-person cycling class were generated. Using Taguchi L9 (34) orthogonal arrays method, nine spatial scenarios were simulated with three different thermal operations each. Optimal factor levels were determined by using thermal comfort conditions (based on predicted mean vote) around the body's thermal plume. The results showed that a ceiling height of 5 m, lateral and frontal distances of 1 m and 0.5 m between machines, and Type 2 (two inlets mounted on the ceiling) ventilation strategy were optimal for achieving better thermal comfort values in a thermal condition of 18 °C and 0.2 m·s−1. The study found that increasing the ceiling height and using cross-positioned vents that project air vertically from the ceiling improved the comfort conditions significantly. It is expected that these criteria, which were determined, compared with the standards and detailed, will contribute to the production processes of comfortable exercise spaces. © 2023 Elsevier B.V.Book Part 1960s Tax Law and Non-Muslim Exodus From Istanbul: Turkification of the City(Taylor & Francis, 2023) Akpınar, İpekThis chapter discusses the urban consequences of the expulsion of Istanbul Greeks in 1964. It demonstrates the urban impact of the 16 March 1964 decree that terminated the residence of 12, 000 Greek passport holders in Istanbul (a population of 40, 000 with their relatives), who were given 24 hours to leave the city and allowed to carry only 20 kilograms of belongings or US$22 with them. The event also alarmed many other non-Muslim families to emigrate from Istanbul, while the city was receiving a large influx of immigrants from rural lands due to the growing industrialization and urbanization. Akpinar discusses the urban planning interventions in Istanbul under the Menderes and subsequent governments throughout the 1950s and 1960s as ad-hoc or intentional steps toward Turkification, in which discrimination and the resulting emigration of Istanbul Greeks played a significant part. © 2024 selection and editorial matter, Esra Akcan and Iftikhar Dadi; individual chapters, the contributors.Article Citation - WoS: 4Impact of Window-To Surface Area for Different Window Glass Types and Wall Orientations on Building Energy Performance: a Case Study for a School Building Located in Izmir, Turkey(Yıldız Teknik Üniversitesi, 2011) Yildiz, Yusuf; Ozbalta, Trkan Goksal; Arsan, Zeynep DurmusThe opaque and transparent surfaces of buildings have an important role in the total percentage of energy loss or gain. Heat loss or gain from windows are dependent on the window-to-wall area ratio, the window glass type, and the type of window frame used. In the concept of energy efficient design, heat loss or gain from windows should be analyzed in detail in the early stages of building design by considering local climatic conditions. This study investigates a school building located in Izmir in Turkey, a city with a hot and humid climate. Various glass types with different glazing characteristics and number of layers, located in different parts of the buildings and with different window-to-wall ratios are analyzed and compared using building the energy analysis program "EnergyPlus". Results indicate that window-to-wall area ratios, wall orientation and glass types are important factors in the building's total energy consumption. When the window-to-wall area ratio is increased from 10% to 60%, the winter heating load of the building decreases in maximum amount on the south side of the building and reduces in minimum amount on the east side of the building. When summer cooling load is investigated the highest increase in energy consumption is found on the south side of the building. On the eastern and western sides of the building the effect of increased energy consumption value remains low. When the total energy consumption (cooling + heating) is considered, it is calculated that the east and west sides have the biggest total effect and the northern wall has the smallest total effect. When low emissivity glass is used instead of double layer glass, in terms of energy consumption the building side order of effect remains the same, although actual values differ. It is therefore clear that using energy analysis programs to analyse different factors within the energy consumption of buildings will be beneficial in creating energy efficient solutions. This can be carried out in the earlier stages of the architectural design of the buildings or at the renovation stages of existing buildings.Article Citation - WoS: 7Investigation of Educational Buildings in Terms of Daylighting Performance(Yıldız Teknik Üniversitesi, 2011) Erlalelitepe, Ilknur; Aral, Duygu; Kazanasmaz, TugceEducational buildings have the priority among other building types in daylight performance studies. There are several reasons for this. Classrooms which are used during the whole day should have sufficient and homogeneously distributed daylight. In insufficient daylight conditions, the use of electrical lighting increases energy consumption. Users' visual comfort should also be assured, and design incorporating natural light requires the analysis of sun protection devices in order to avoid glare and excessive heat. Also, atriums and skylights can be included in the building design with the aim of distributing light equally and in a relatively balanced manner throughout the building. However, lighting schemes are often proposed by architects and professionals who tend to make use of different design tools, and it would be pertinent to investigate whether these tools perform as desired. This study analyses daylight design principles and design elements in educational buildings. It outlines the method which has been used to analyse the daylight performance of buildings. A university building was selected for the field study. Measurements were taken in sample spaces to determine daylight performance. Utilising comparison between standard values and measured values, findings are presented in the form of tables, drawings and figures.Article A Fuzzy Logic Model To Classify Design Efficiency of Nursing Unit Floors(Yıldız Teknik Üniversitesi, 2010) Kazanasmaz, Tugce; Tayfur, GokmenThis study was conducted to determine classifications for the planimetric design efficiency of certain public hospitals by developing a fuzzy logic algorithm. Utilizing primary areas and circulation areas from nursing unit floor plans, the study employed triangular membership functions for the fuzzy subsets. The input variables of primary areas per bed and circulation areas per bed were fuzzified in this model. The relationship between input variables and output variable of design efficiency were displayed as a result of fuzzy rules. To test existing nursing unit floors, efficiency output values were obtained and efficiency classes were constructed by this model in accordance with general norms, guidelines and previous studies. The classification of efficiency resulted from the comparison of hospitals.Article Citation - WoS: 2The Development of Western-Type Large-Scale Consumption Areas in Turkey and Legal and Structural Regulation Efforts in Urban Retail Environments(Yıldız Teknik Üniversitesi, 2009) Kompil, Mert; Celik, MuratThe retail sector has been experiencing a rapid and continuous change worldwide. There have also been profound changes in Turkey, especially after the 1980s. Both the retail sector and the urban retail environments have been altered radically. One of the most significant indicators of this change is the proliferation of western-type large-scale retail developments. Past experiences in developed countries have shown that the uncontrolled development of large-scale retail areas results in some undesired socioeconomic and physical outcomes, such as decline in the cultural and commercial activities of city centers, damage in existing retail workforce structure, and change in local retail hierarchy, nearby land uses, traffic loads and original architectural identity. Many countries have put into practice restrictive and regulatory policies to prevent these negative effects. As similar transformations have also been realized in Turkish retail environments, many institutions think that similar legal regulations must be implemented in Turkey as well. The present study investigates the ongoing retail change within the Turkish context, explores the legal and structural regulatory policies of the Organization for Economic Co-operation and Development (OECD) countries, and critically discusses the appropriate retail regulation policies for Turkey.Article Efficient Design of Nursing Unit Floors(Yıldız Teknik Üniversitesi, 2009) Kazanasmaz, Z. Tugce; Duzgunes, ArdaHospital designs aim to obtain the lowest possible construction, maintenance and operational costs together with patient satisfaction, comfort and privacy. To satisfy these needs, the efficient design of nursing unit areas becomes considerably important. This study was thus conducted to analyze planimetric design efficiency of nursing unit floors by defining certain floor areas and floor area ratios. To test existing nursing unit floors, quantitative assessments were noted in regard to their planimetric efficiency: the utility value of the built floor area, both in terms of its allocation to patient space (served), support (serving) and circulation space and the relative proportions of these. Results were presented in a comparative table. Of the 15 hospital floor plans analyzed, five satisfied minimum space requirements for patient areas, while another five were in the optimum range for circulation areas. Two were defined as the least efficient, having the lowest patient-to-circulation area ratio.Conference Object Leed Certification: a Comparison of Contractors' Perspectives(Research Publishing Services, 2013) Doğan, Sevgi Zeynep; Günhan, Suat; Gerçek, Bilge; Arditi, DavidThe Leadership in Energy and Environmental Design (LEED) certification system for green buildings has been used extensively in the US and has gained increased attention in developing countries as well. The related literature focuses extensively on the perspectives of owners and designers, whereas constructors' role receives less attention. One significant research is based on a survey administered to 22 contractors, who built LEED certified green building projects in the US. The survey inquired about earned LEED credits and best practices in LEED certification process regarding past experiences. The same survey was administered to seven Turkish contractors, who also built LEED certified green buildings in Turkey. The similarities and differences between US and Turkish constructors' perspectives were studied. Both groups stated that the LEED process was slightly difficult or was just straightforward. US contractors needed a lot of additional time for the LEED documentation; Turkish contractors required no extra time. LEED certification system incurred a little additional cost for US contractors; however Turkish contractors mentioned about up to 10% additional project costs. The achieved LEED credits from materials and resources, and indoor environmental quality by the two groups of contractors were highly correlated. Both groups emphasized the inclusion of LEED documentation and specifications in coordination meetings and in subcontracts to streamline the process; and emphasized the early collaboration of the entire project team for earning LEED credits. Copyright © 2013 by Research Publishing Services.
