This item is non-discoverable
Alpkaya, Alican Tuncay
Loading...
Profile URL
Name Variants
Job Title
Email Address
Main Affiliation
01. Izmir Institute of Technology
Status
Current Staff
Website
ORCID ID
Scopus Author ID
Turkish CoHE Profile ID
Google Scholar ID
WoS Researcher ID
Sustainable Development Goals
1NO POVERTY
0
Research Products
2ZERO HUNGER
0
Research Products
3GOOD HEALTH AND WELL-BEING
0
Research Products
4QUALITY EDUCATION
0
Research Products
5GENDER EQUALITY
0
Research Products
6CLEAN WATER AND SANITATION
0
Research Products
7AFFORDABLE AND CLEAN ENERGY
0
Research Products
8DECENT WORK AND ECONOMIC GROWTH
0
Research Products
9INDUSTRY, INNOVATION AND INFRASTRUCTURE
1
Research Products
10REDUCED INEQUALITIES
0
Research Products
11SUSTAINABLE CITIES AND COMMUNITIES
0
Research Products
12RESPONSIBLE CONSUMPTION AND PRODUCTION
0
Research Products
13CLIMATE ACTION
0
Research Products
14LIFE BELOW WATER
0
Research Products
15LIFE ON LAND
0
Research Products
16PEACE, JUSTICE AND STRONG INSTITUTIONS
0
Research Products
17PARTNERSHIPS FOR THE GOALS
0
Research Products

This researcher does not have a Scopus ID.

This researcher does not have a WoS ID.
Publication Collaboration
| Affiliation Name | Count |
|---|---|
| Izmir Institute of Technology | 7 |
| Izmir Kâtip Çelebi University | 2 |
| Istanbul University-Cerrahpaşa | 2 |
| Izmir Atatürk Eğitim ve Araştırma Hastanesi | 2 |
| Kırklareli University | 1 |
1 / 2
Data obtained from OpenAlex

Scholarly Output
9
Articles
5
Views / Downloads
3127/555
Supervised MSc Theses
0
Supervised PhD Theses
1
WoS Citation Count
50
Scopus Citation Count
61
Patents
0
Projects
0
WoS Citations per Publication
5.56
Scopus Citations per Publication
6.78
Open Access Source
4
Supervised Theses
1
| Journal | Count |
|---|---|
| Scientific Data | 2 |
| Hittite Journal of Science and Engineering | 1 |
| Medical Engineering & Physics | 1 |
| Medical Engineering and Physics | 1 |
| Strain | 1 |
Current Page: 1 / 2
Scopus Quartile Distribution
Competency Cloud

9 results
Scholarly Output Search Results
Now showing 1 - 9 of 9
Correction Database Covering the Prayer Movements Which Were Not Available Previously (Vol 10, 276, 2023)(Nature Portfolio, 2025) Mihçin, Şenay; Alpkaya, Alican Tuncay; Şahin, Serap; Alpkaya, Alican Tuncay; Tuna, Merve; Akdeniz, Sevinc; Sahin, Serap; 01. Izmir Institute of Technology; 03. Faculty of Engineering; 03.04. Department of Computer Engineering; 03.10. Department of Mechanical EngineeringData Paper Database Covering the Previously Excluded Daily Life Activities(2023) Mihçin, Şenay; Şahin, Ahmet Mert; Mihçin, Şenay; Alpkaya, Alican Tuncay; Tuna, Merve; Alpkaya, Alican Tuncay; Şahin, Serap; Akdeniz, Sevinç; Şahin, Serap; 03.04. Department of Computer Engineering; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringIn biomedical engineering, implants are designed according to the boundary conditions of gait data and tested against. However, due to diversity in cultural backgrounds, religious rituals might cause different ranges of motion and different loading patterns. Especially in the Eastern part of the world, diverse Activities of Daily Living (ADL) consist of salat, yoga rituals, and different style sitting postures. Although databases cover ADL for the Western population, a database covering these diverse activities of the Eastern world, specific to these populations is non-existent. To include previously excluded ADL is a key step in understanding the kinematics and kinetics of these activities. By means of developments in motion capture technologies, excluded ADL data are captured to obtain the coordinate values to calculate the range of motion and the joint reaction forces. This study focuses on data collection protocol and the creation of an online database of previously excluded ADL activities, targeting 200 healthy subjects via Qualisys and IMU motion capture systems, and force plates, from West and Middle East Asian populations. Anthropometrics are known to affect kinematics and kinetics which are also included in the collected data. The current version of the database covers 50 volunteers for 12 different activities, the database aims for 100- male and 100- female healthy volunteers as the final target including C3D and BVH file types. The tasks are defined and listed in a table to create a database to make a query based on age, gender, BMI, type of activity and motion capture system. The data is collected only from a healthy population to understand healthy motion patterns during these previously excluded ADLs. The collected data is to be used for designing implants to allow these sorts of activities to be performed without compromising the quality of life of patients performing these activities in the future.Article Citation - WoS: 8Citation - Scopus: 9Dynamic Computational Wear Model of Peek-On Bearing Couple in Total Hip Replacements(Elsevier, 2023) Alpkaya, Alican Tuncay; Alpkaya, Alican Tuncay; Mihçin, Şenay; Mihçin, Şenay; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringUnderstanding wear mechanisms is a key factor to prevent primary failures causing revision surgery in total hip replacement (THR) applications. This study introduces a wear prediction model of (Polyetheretherketone) PEEK-on-XLPE (cross-linked polyethylene) bearing couple utilized to investigate the wear mechanism under 3D-gait cycle loading over 5 million cycles (Mc). A 32-mm PEEK femoral head and 4-mm thick XLPE bearing liner with a 3-mm PEEK shell are modeled in a 3D explicit finite element modeling (FEM) program. The volumetric and linear wear rates of XLPE liner per every million cycles were predicted as 1.965 mm3/Mc, and 0.0032 mm/Mc respectively. These results are consistent with the literature. PEEK-on-XLPE bearing couple exhibits a promising wear performance used in THR application. The wear pattern evolution of the model is similar to that of conventional polyethylene liners. Therefore, PEEK could be proposed as an alternative material to the CoCr head, especially used in XLPE-bearing couples. The wear prediction model could be utilized to improve the design parameters with the aim of prolonging the life span of hip implants. © 2023Article Sensitivity Analysis of Wear on Metal-On Bearing Couples Via Verification of Numeric and Analytic Methods(2024) Alpkaya, Alican Tuncay; Mihçin, Şenay; Mihcin, Senay; Alpkaya, Alican Tuncay; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringWear mechanism is important since it leads to revisions in Total Hip Replacement (THR) surgeries. Contact pressure plays an important role in wear mechanisms and needs to be investigated in detail to obtain more accurate wear predictions to understand the wear performance of the implant in the design stage. This study proposes a methodology for verification of contact pressure and pressure distribution via numeric and analytic methods to be used in wear calculations. Based on Hertz’s contact theory, the contact pressure and the contact area ae calculated in the analytical method. The results are compared to the numeric method’s results obtained from the finite element method. The linear and volumetric wear rates of bearing couples’ surfaces were estimated by Archard’s wear equation. The effect of design parameters on pressure such as head radius, cup thickness, material combination of bearing couples, coating film material, and film thickness are investigated in this study using the proposed methodology. The minimum error between the analytical and numerical results was 0.24% for 28 mm of head diameter, while the maximum error was 11.79 % for 48- mm of head diameter. The minimum contact pressure values were obtained from 48- mm of head radius at a half contact angle of 190 (degrees) in FEM and Hertz calculations, respectively. The maximum linear wear rate was calculated at 0.0026 mm/Mc at a 1- mm cup thickness, while minimum linear wear rate was 0.0022 mm/Mc at a 10- mm cup thickness in the numeric method. The maximum survival cycles of coating materials rate were 31847 cycles for the Stainless-steel coated cup with 500 μm of coating thickness, while the minimum cycles was 2359 cycles for the Ti64 coated cup surface with 100 μm of coating thickness. It is concluded that the most important design parameters are the cup thickness and the material combinations since they have a significant effect on the contact pressure and the contact area. This study provides a verification methodology for the parametric sensitivity analysis before experimental validations. The methodology utilized in this study could be utilized by designers while optimizing the design parameters to minimize the wear.Article Citation - WoS: 7Citation - Scopus: 10The Computational Approach To Predicting Wear: Comparison of Wear Performance of Cfr-Peek and Xlpe Liners in Total Hip Replacement(Taylor & Francis, 2022) Alpkaya, Alican Tuncay; Mihçin, Şenay; Alpkaya, Alican Tuncay; Mihçin, Şenay; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringWear on articulating bearing surfaces is a key factor causing revision in total hip replacement (THR). Wear debris that releases particles from bearing surfaces might result in adverse soft tissue reactions requiring revision surgeries. In this study, a comprehensive computational wear model based on the Archard wear equation was performed to investigate the wear performance under a three-dimensional (3D) physiological gait cycle, mimicking a normal walking condition (5 million cycles). The study shows that the accuracy of the model is highly dependent on the mesh convergence, the wear fraction, and the scaling factor. The simulations were run to provide a vast amount of detail for the reproducibility of the work. Cobalt chromium (CoCr) on cross-linked polyethylene (XLPE) and CoCr on carbon-fiber-reinforced polyether ether ketone (CFR-PEEK) prototype models were created in silico. The volumetric wear rates for CoCr-on-XLPE were calculated as 0.2989 (Formula presented.) for CoCr head and 21.0271 (Formula presented.) for XLPE liner, while for CoCr-on-CFR-PEEK they were 0.3484 (Formula presented.) for CoCr head and 1.8476 (Formula presented.) for CFR-PEEK liner. When compared to in vivo and in vitro studies, the wear patterns of these two prototypes are consistent with those of the conventional polyethylene liners in the literature. Although the volumetric wear rate of the CFR-PEEK liner is about 11 times lower than the counterpart of XLPE in MoP implants, the wear rate of CoCr was higher when compared to its use with XLPE. Therefore, CFR-PEEK articulating against orthopa\edic metals may not be as good an alternative as XLPE, due to higher indicative metallic wear. This detailed computational wear modeling methodology could be utilized in design improvements of implants.Data Paper Citation - WoS: 15Citation - Scopus: 20Database Covering the Prayer Movements Which Were Not Available Previously(Nature Publishing Group, 2023) Mihçin, Şenay; Şahin, Ahmet Mert; Alpkaya, Alican Tuncay; Alpkaya, Alican Tuncay; Tuna, Merve; Mihçin, Şenay; Can, Nuray Korkmaz; Tosun, Aliye; Şahin, Serap; 03.04. Department of Computer Engineering; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringLower body implants are designed according to the boundary conditions of gait data and tested against. However, due to diversity in cultural backgrounds, religious rituals might cause different ranges of motion and different loading patterns. Especially in the Eastern part of the world, diverse Activities of Daily Living (ADL) consist of salat, yoga rituals, and different style sitting postures. A database covering these diverse activities of the Eastern world is non-existent. This study focuses on data collection protocol and the creation of an online database of previously excluded ADL activities, targeting 200 healthy subjects via Qualisys and IMU motion capture systems, and force plates, from West and Middle East Asian populations with a special focus on the lower body joints. The current version of the database covers 50 volunteers for 13 different activities. The tasks are defined and listed in a table to create a database to search based on age, gender, BMI, type of activity, and motion capture system. The collected data is to be used for designing implants to allow these sorts of activities to be performed.Article Citation - WoS: 13Citation - Scopus: 14The Quasi-Static Crush Response of Electron-Beam Ti6al4v Body-Centred Lattices: The Effect of the Number of Cells, Strut Diameter and Face Sheet(Wiley, 2022) Güden, Mustafa; Alpkaya, Alican Tuncay; Taşdemirci, Alper; Hızlı, Burak; Taşdemirci, Alper; Alpkaya, Alican Tuncay; Hızlı, Burak; Güden, Mustafa; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringThe effect of the number of cells, strut diameter and face sheet on the compression of electron-beam-melt (EBM) Ti6Al4V (Ti64) body-centred-cubic (BCC) lattices was investigated experimentally and numerically. The lattices with the same relative density (~0.182) were fabricated with and without 2-mm-thick face sheets in 10 and 5 mm cell size, 8–125 unit cell (two to five cells/edge) and 2 and 1 mm strut diameter. The experimental compression tests were further numerically simulated in the LS-DYNA. Experimentally two bending-dominated crushing modes, namely, lateral and diagonal layer crushing, were determined. The numerical models however exhibited merely a bending-dominated lateral layer crushing mode when the erosion strain was 0.4 and without face-sheet models showed a diagonal layer crushing mode when the erosion strain was 0.3. Lower erosion strains promoted a diagonal layer crushing mode by introducing geometrical inhomogeneity to the lattice, leading to strain localisation as similar to the face sheets which introduced extensive strut bending in the layers adjacent to the face sheets. The face-sheet model showed a higher but decreasing collapse strength at an increasing number of cells, just as opposite to the without face-sheet model, and the collapse strength of both models converged when the number of cells was higher than five-cell/edge. The decrease/increase of the collapse strengths of lattices before the critical number of cells was claimed mainly due to the size-imposed lattice boundary condition, rather than the specimen volume. The difference in the experimental collapse strengths between the 5- and the 10-mm cell-size lattices was ascribed to the variations in the microstructures—hence the material model parameters between the small-diameter and the large-diameter EBM-Ti64 strut lattices.Article Citation - WoS: 7Citation - Scopus: 8Investigation of Stair Ascending and Descending Activities on the Lifespan of Hip Implants(Elsevier Sci Ltd, 2024) Alpkaya, Alican Tuncay; Alpkaya, Alican Tuncay; Yilmaz, Mehmet; Mihçin, Şenay; Sahin, Ahmet Mert; Mihcin, Senay; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringTotal hip arthroplasty (THA) surgeries among young patients are on the increase, so it is crucial to predict the lifespan of hip implants correctly and produce solutions to improve longevity. Current implants are designed and tested against walking conditions to predict the wear rates. However, it would be reasonable to include the additional effects of other daily life activities on wear rates to predict convergent results to clinical outputs. In this study, 14 participants are recruited to perform stair ascending (AS), descending (DS), and walking activities to obtain kinematic and kinetic data for each cycle using marker based Qualisys motion capture (MOCAP) system. AnyBody Modeling System using the Calibrated Anatomical System Technique (CAST) full body marker set are performed Multibody simulations. The 3D generic musculoskeletal model used in this study is a markerbased full-body motion capture model (AMMR,2.3.1 MoCapModel) consisting of the upper extremity and the Twente Lower Extremity Model (TLEM2). The dynamic wear prediction model detailing the intermittent and overall wear rates for CoCr-on-XLPE bearing couple is developed to investigate the wear mechanism under 3D loading for AS, DS, and walking activities over 5 million cycles (Mc) by using finite element modelling technique. The volumetric wear rates of XLPE liner under AS, DS, and walking activities over 5-Mc are predicted as 27.43, 23.22, and 18.84 mm3/Mc respectively. Additionally, the wear rate was predicted by combining stair activities and gait cycles based on the walk-to-stair ratio. By adding the effect of stair activities, the volumetric wear rate of XLPE is predicted as 22.02 mm3/Mc which is equivalent to 19.41% of walking. In conclusion, in this study, the effect of including other daily life activities is demonstrated and evidence is provided by matching them to the clinical data as opposed to simulator test results of implants under ISO 14242 boundary conditions.Doctoral Thesis Dynamic Wear Simulations of Hip Implants for Daily Life Activities(01. Izmir Institute of Technology, 2024) Alpkaya, Alican Tuncay; Mihçin, Şenay; Mihçin, Şenay; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of EngineeringTotal hip replacement is widely used around the world for patients whose hip joints lost their functionality. Despite its wide applications and technological developments taking place in the recent years, it still does not produce near-perfect results. It has been observed that many patients with implants have their range of motion often restricted. Although there has been literature covering the daily life motion profiles in Western societies, , it has been observed that a through database of activities including sitting, worship, and lifestyles suitable for Middle Eastern societies is non-existent.Therefore, it is difficult to determine the lifespan of implants used especially in these societies and to determine their wear rates with accuracy. In this thesis, I have utilized the first comprehensive database of daily activities of Turkish population, which was formed using the state-of-the-art motion capture (MOCAP) technologies at Biomechanics and Motion Capture Laboratory of IZTECH. The range of motion and reaction force data were calculated using the inverse kinematics and kinetics methods previously. This previously calculated boundary conditions are fed into the finite element models of hip implants to simulate ten distinct daily life activities Asian style sitting, normal walking cycle, obstacle crossing, Stoop lifting, Squat lifting, Ruku' and I'tıdal, Ruku to Sujud, Sujud, Ascending stairs, and Descending Stairs. The dynamic simulations of hip implants under these boundary conditions are performed in this thesis. In this thesis, a computational wear methodology is utilized to assess the wear performance of hip bearing surfaces under these boundary conditions. Each comprehensive computational wear simulations of each of these daily life activities over five million cycles is performed to provide omputational evidence on the wear rates to assess the wear performance of the bearing couple. The wear prediction model could be utilized to provide guidance on the design parameters with the aim of prolonging the life span of hip implants.
