Aydeniz, Emre

Loading...
Name Variants
Job Title
Email Address
Main Affiliation
01. Izmir Institute of Technology
Status
Current Staff
Website
ORCID ID
Scopus Author ID
Turkish CoHE Profile ID
Google Scholar ID
WoS Researcher ID

Sustainable Development Goals

SDG data is not available
This researcher does not have a Scopus ID.
This researcher does not have a WoS ID.
No records found in other affiliations.
Scholarly Output

1

Articles

0

Views / Downloads

842/486

Supervised MSc Theses

1

Supervised PhD Theses

0

WoS Citation Count

0

Scopus Citation Count

0

Patents

0

Projects

0

WoS Citations per Publication

0.00

Scopus Citations per Publication

0.00

Open Access Source

1

Supervised Theses

1

Journals data is not available

Scopus Quartile Distribution

Quartile distribution chart data is not available

Competency Cloud

GCRIS Competency Cloud

Scholarly Output Search Results

Now showing 1 - 1 of 1
  • Master Thesis
    Experimental Investigation of the Pressure Drop Performance and the Cavitation of a Plunger Valve
    (Izmir Institute of Technology, 2020) Aydeniz, Emre; Özkol, Ünver; Özkol, Ünver; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03. Faculty of Engineering
    This thesis, realized within the scope of a TUBITAK project of DOĞUġ VANA A.ġ, is aimed to characterize the pressure drop and cavitation performance of plunger valve with various cavitation lattices in different opening ratios. Pressure drop performance and cavitation studies have been examined experimentally. Loss coefficients and flow coefficients were used to examine the pressure drop performance of four different types of cavitation lattices. According to the results of this experimental study, it was observed that the loss coefficient is almost independent of Reynolds number except for Re < 4x105. Cavitation creates vibration and noise in high-frequency ranges. Therefore, cavitation detection was examined in the high-frequency range of 5 kHz to 18 kHz and was performed using an accelerometer. Fourier Transform (FT) and Power Spectrum Density (PSD) were used to measure the energy levels of vibrations. Cavitation limits (incipient and critical cavitation) were detected by comparing PSD levels and cavitation indexes at different aperture ratios for all lattices. As a result, the safe cavitation range for the valve was determined by comparing the cavitation indexes according to the valve opening ratio. A new cavitation index estimation study was performed for the new diameter and upstream pressure values with the effect of size scaling and pressure scaling.