Fiber Optic Sensors Using Novel Substrates for Hydrogen Sulfide Determination by Solid Surface Fluorescence
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Open Access Color
BRONZE
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
Two different fiber optic sensors were developed for the determination of hydrogen sulfide at ppb concentration levels; a probe-type fiber optic sensor coated with polyethylene oxide containing 0.5 M CdCl2 and a fiber optic sensor utilizing 0.5 M CdCl2-pretreated filter paper as solid substrate. In the first type, CdCl2–polyethyleneoxide (PEO) mixture was coated onto the tip of a fiber optic probe and the probe was exposed to H2S. The methodology is based on the measurement of CdS fluorescence on the surface. Detection limit (3s) of the PEO-coated fiber optic system was 36.0 ppb for H2S and precision at the 0.552 ppm level was 29% R.S.D. For the fiber optic system utilizing CdCl2-pretreated filter paper, two different configurations were devised and evaluated; a bifurcated fiber optic sensor and a single fiber optic sensor. Similar figures were obtained with these two systems; the detection limit (3s) was 4.0 ppb for the bifurcated fiber optic sensor and 4.3 ppb for the single fiber optic sensor, and both sensors had linear responses in the range 0.032–1.0 ppm. Their precisions at 0.299 ppm level were also very similar, 10 and 11% R.S.D., respectively, for the bifurcated and single fiber systems. In addition to the fiber optic sensors developed, various surfactants (sodiumdodecylsulfate (SDS), Aerosol OT, Aerosol A102, Aerosol 501), some cellulosic substances (sodium carboxymethylcellulose (CMC), ethylcellulose, hydroxypropylmethylcellulose, ethylhydroxyethylcellulose, α-cellulose) and several water-soluble polymers (polyacrylicacid polyethleneoxide (PEO), polyvinylalcohol (PVA)) were dissolved in proper solvents and after mixing with 0.5 M CdCl2, were spread over glass slides. These novel solid substrates were exposed to H2S and fluorescence signal on the surfaces of the glass slides was measured with a luminescence spectrometer. The new substrates were shown to be good alternatives to filter paper for the determination of H2S by room temperature solid surface fluorescence spectrometry.
Description
Keywords
Hydrogen sulfide, Room temperature fluorescence, Solid surface fluorescence, Fiber optic sensors, Hydrogen sulfide, Fiber optic sensors, Solid surface fluorescence, Room temperature fluorescence
Fields of Science
02 engineering and technology, 0210 nano-technology, 01 natural sciences, 0104 chemical sciences
Citation
Eroğlu, Ahmet E., Volkan, Mürvet, & Ataman, O. Y. (2000). Fiber optic sensors using novel substrates for hydrogen sulfide determination by solid surface fluorescence. Talanta, 53(1), 89–101. doi:10.1016/S0039-9140(00)00377-5
WoS Q
Scopus Q

OpenCitations Citation Count
15
Source
Volume
53
Issue
Start Page
89
End Page
101
PlumX Metrics
Citations
CrossRef : 9
Scopus : 26
Captures
Mendeley Readers : 29
Google Scholar™


