Preconcentration and Atomic Spectrometric Determination of Rare Earth Elements (rees) in Natural Water Samples by Inductively Coupled Plasma Atomic Emission Spectrometry
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Open Access Color
BRONZE
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
The usage of a variety of sorbents has been shown as promising matrix removal/preconcentration strategies for the determination of rare earth elements (REEs) in various natural water samples by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sorption efficiency of various zeolites (clinoptilolite, mordenite, zeolite Y, zeolite Beta), ion-exchangers (Amberlite CG-120, Amberlite IR-120, Rexyn 101, Dowex 50W X18) and chelating resins (Muromac, Chelex 100, Amberlite IRC-718) towards REEs was investigated in terms of solution pH, shaking time and sorbent amount. The results have shown that most of the materials can take up REEs at a wide pH range. The experiments were continued with clinoptilolite, zeolite Y and Chelex 100 and it was demonstrated that all three materials displayed very fast kinetics for REE sorption (higher than 96% in 1 min). Desorption from the sorbents was realized with 2.0 M HNO3 for clinoptilolite and 0.1 M HNO3 for zeolite Y and Chelex 100. Only the lower concentration range (0.01–2.0 mg l−1) of matrix-matched standards were used in quantitation although the calibration graphs were linear at least up to 10.0 mg l−1 for all REEs studied. The limit of detection (3 s) without preconcentration was 0.1, 1.0, and 0.2 μg l−1 for Eu, La, and Yb, respectively. The validity of the method with the selected sorbents was checked through spike recovery experiments.
Description
Fields of Science
01 natural sciences, 0104 chemical sciences
Citation
Pasinli, T., Eroğlu, Ahmet E., & Shahwan, T. (2005). Preconcentration and atomic spectrometric determination of rare earth elements (REEs) in natural water samples by inductively coupled plasma atomic emission spectrometry. Analytica Chimica Acta, 547(1), 42–49. doi:10.1016/j.aca.2005.04.076
WoS Q
Q1
Scopus Q
Q1

OpenCitations Citation Count
55
Source
Analytica Chimica Acta
Volume
547
Issue
1
Start Page
42
End Page
49
PlumX Metrics
Citations
CrossRef : 41
Scopus : 60
Captures
Mendeley Readers : 42
SCOPUS™ Citations
60
checked on Jun 17, 2026
Web of Science™ Citations
62
checked on Jun 17, 2026
Page Views
941
checked on Jun 17, 2026
Downloads
521
checked on Jun 17, 2026
Google Scholar™


