Preconcentration and Atomic Spectrometric Determination of Rare Earth Elements (rees) in Natural Water Samples by Inductively Coupled Plasma Atomic Emission Spectrometry

Loading...

Date

Authors

Eroğlu, Ahmet Emin
Shahwan, Talal

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

BRONZE

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Top 10%
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

The usage of a variety of sorbents has been shown as promising matrix removal/preconcentration strategies for the determination of rare earth elements (REEs) in various natural water samples by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sorption efficiency of various zeolites (clinoptilolite, mordenite, zeolite Y, zeolite Beta), ion-exchangers (Amberlite CG-120, Amberlite IR-120, Rexyn 101, Dowex 50W X18) and chelating resins (Muromac, Chelex 100, Amberlite IRC-718) towards REEs was investigated in terms of solution pH, shaking time and sorbent amount. The results have shown that most of the materials can take up REEs at a wide pH range. The experiments were continued with clinoptilolite, zeolite Y and Chelex 100 and it was demonstrated that all three materials displayed very fast kinetics for REE sorption (higher than 96% in 1 min). Desorption from the sorbents was realized with 2.0 M HNO3 for clinoptilolite and 0.1 M HNO3 for zeolite Y and Chelex 100. Only the lower concentration range (0.01–2.0 mg l−1) of matrix-matched standards were used in quantitation although the calibration graphs were linear at least up to 10.0 mg l−1 for all REEs studied. The limit of detection (3 s) without preconcentration was 0.1, 1.0, and 0.2 μg l−1 for Eu, La, and Yb, respectively. The validity of the method with the selected sorbents was checked through spike recovery experiments.

Description

Keywords

Rare earth element, Inductively coupled plasma atomic emission spectrometry (ICP-AES), Preconcentration, Clinoptilolite, Zeolite Y, Chelex 100, Clinoptilolite, Inductively coupled plasma atomic emission spectrometry (ICP-AES), Zeolite Y, Chelex 100, Rare earth element, Preconcentration

Fields of Science

01 natural sciences, 0104 chemical sciences

Citation

Pasinli, T., Eroğlu, Ahmet E., & Shahwan, T. (2005). Preconcentration and atomic spectrometric determination of rare earth elements (REEs) in natural water samples by inductively coupled plasma atomic emission spectrometry. Analytica Chimica Acta, 547(1), 42–49. doi:10.1016/j.aca.2005.04.076

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
55

Volume

547

Issue

1

Start Page

42

End Page

49
PlumX Metrics
Citations

CrossRef : 41

Scopus : 60

Captures

Mendeley Readers : 42

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.94537053

Sustainable Development Goals