Modeling and Simulation of Positron Emission Mammography (pem) Based on Double-Sided Cdte Strip Detectors
| dc.contributor.author | Özşahin, İlker | |
| dc.contributor.author | Ünlü, Mehmet Zübeyir | |
| dc.coverage.doi | 10.1088/1748-0221/9/03/C03055 | |
| dc.date.accessioned | 2017-05-25T08:31:39Z | |
| dc.date.available | 2017-05-25T08:31:39Z | |
| dc.date.issued | 2014 | |
| dc.description.abstract | Breast cancer is the most common leading cause of cancer death among women. Positron Emission Tomography (PET) Mammography, also known as Positron Emission Mammography (PEM), is a method for imaging primary breast cancer. Over the past few years, PEMs based on scintillation crystals dramatically increased their importance in diagnosis and treatment of early stage breast cancer. However, these detectors have significant limitations like poor energy resolution resulting with false-negative result (missed cancer), and false-positive result which leads to suspecting cancer and suggests an unnecessary biopsy. In this work, a PEM scanner based on CdTe strip detectors is simulated via the Monte Carlo method and evaluated in terms of its spatial resolution, sensitivity, and image quality. The spatial resolution is found to be ∼ 1 mm in all three directions. The results also show that CdTe strip detectors based PEM scanner can produce high resolution images for early diagnosis of breast cancer. | en_US |
| dc.identifier.citation | Özşahin, I., and Ünlü, M.Z. (2014). Modeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectors. Journal of Instrumentation, 9(3). doi:10.1088/1748-0221/9/03/C03055 | en_US |
| dc.identifier.doi | 10.1088/1748-0221/9/03/C03055 | |
| dc.identifier.doi | 10.1088/1748-0221/9/03/C03055 | en_US |
| dc.identifier.issn | 1748-0221 | |
| dc.identifier.scopus | 2-s2.0-84898899855 | |
| dc.identifier.uri | https://doi.org/10.1088/1748-0221/9/03/C03055 | |
| dc.identifier.uri | https://hdl.handle.net/11147/5610 | |
| dc.language.iso | en | en_US |
| dc.publisher | IOP Publishing Ltd. | en_US |
| dc.relation.ispartof | Journal of Instrumentation | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Gamma camera | en_US |
| dc.subject | SPECT | en_US |
| dc.subject | Computerized tomography | en_US |
| dc.subject | Computed radiography | en_US |
| dc.subject | X-ray mammography | en_US |
| dc.title | Modeling and Simulation of Positron Emission Mammography (pem) Based on Double-Sided Cdte Strip Detectors | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| gdc.author.institutional | Ünlü, Mehmet Zübeyir | |
| gdc.author.yokid | 42462 | |
| gdc.bip.impulseclass | C5 | |
| gdc.bip.influenceclass | C5 | |
| gdc.bip.popularityclass | C5 | |
| gdc.coar.access | open access | |
| gdc.coar.type | text::journal::journal article | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | İzmir Institute of Technology. Electrical and Electronics Engineering | en_US |
| gdc.description.issue | 3 | en_US |
| gdc.description.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| gdc.description.scopusquality | Q3 | |
| gdc.description.volume | 9 | en_US |
| gdc.description.wosquality | Q4 | |
| gdc.identifier.openalex | W2126090461 | |
| gdc.identifier.wos | WOS:000336123200055 | |
| gdc.index.type | WoS | |
| gdc.index.type | Scopus | |
| gdc.oaire.accesstype | BRONZE | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.impulse | 0.0 | |
| gdc.oaire.influence | 2.9414648E-9 | |
| gdc.oaire.isgreen | true | |
| gdc.oaire.keywords | Computerized Tomography (CT) and Computed Radiography (CR) | |
| gdc.oaire.keywords | X-ray mammography and scinto- and MRI-mammography | |
| gdc.oaire.keywords | X-ray mammography | |
| gdc.oaire.keywords | Computerized tomography | |
| gdc.oaire.keywords | Computed radiography | |
| gdc.oaire.keywords | SPECT | |
| gdc.oaire.keywords | Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA) | |
| gdc.oaire.keywords | Solid state detectors | |
| gdc.oaire.keywords | Gamma camera | |
| gdc.oaire.popularity | 1.0361121E-9 | |
| gdc.oaire.publicfunded | false | |
| gdc.oaire.sciencefields | 01 natural sciences | |
| gdc.oaire.sciencefields | 03 medical and health sciences | |
| gdc.oaire.sciencefields | 0302 clinical medicine | |
| gdc.oaire.sciencefields | 0103 physical sciences | |
| gdc.openalex.collaboration | National | |
| gdc.openalex.fwci | 0.0 | |
| gdc.openalex.normalizedpercentile | 0.17 | |
| gdc.opencitations.count | 4 | |
| gdc.plumx.crossrefcites | 2 | |
| gdc.plumx.mendeley | 6 | |
| gdc.plumx.scopuscites | 4 | |
| gdc.scopus.citedcount | 4 | |
| gdc.wos.citedcount | 4 | |
| relation.isAuthorOfPublication.latestForDiscovery | 096da1f6-0d36-4fe5-a83c-3a7ff0665b4b | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 9af2b05f-28ac-4018-8abe-a4dfe192da5e |