Yönelimli Eşlenik Noktalar ile Deformasyon Alanı Ara Değerlemesi
| dc.contributor.author | Karaçalı, Bilge | |
| dc.coverage.doi | 10.1109/BIYOMUT.2010.5479857 | |
| dc.date.accessioned | 2021-01-24T18:28:38Z | |
| dc.date.available | 2021-01-24T18:28:38Z | |
| dc.date.issued | 2010 | |
| dc.description.abstract | In this paper, we present a novel method for landmark-based deformation field interpolation that incorporates the rotation information for use in curved medical image registration applications. To this end, each Cartesian component of the interpolated deformation field was modeled by a mixture of Gaussian radial basis functions. The mixture coefficients were identified by optimizing an energy functional that seeks to match the landmark positions as well as the orientations of their neighborhoods. Optimization of this functional was carried out via a gradient descent strategy using the closedform expressions of the partial derivatives with respect to the Gaussian radial basis function coefficients. In the experiments, grater accuracy was observed in the estimation of the unknown deformation fields when the rotation information was incorporated in the interpolation. These results indicate that the proposed scheme can achieve greater accuracy in deformation field interpolation, especially in deformable alignment of multimodality medical images for which the landmarks have to be matched by taking into account the proper orientations of their neighborhoods. ©2010 IEEE. | en_US |
| dc.identifier.doi | 10.1109/BIYOMUT.2010.5479857 | |
| dc.identifier.isbn | 978-142446382-4 | |
| dc.identifier.scopus | 2-s2.0-77954449475 | |
| dc.identifier.uri | https://doi.org/10.1109/BIYOMUT.2010.5479857 | |
| dc.identifier.uri | https://hdl.handle.net/11147/9819 | |
| dc.language.iso | tr | en_US |
| dc.publisher | IEEE | en_US |
| dc.relation.ispartof | 2010 15th National Biomedical Engineering Meeting, BIYOMUT2010 | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Deformation | en_US |
| dc.subject | Medical images | en_US |
| dc.subject | Landmarks | en_US |
| dc.title | Yönelimli Eşlenik Noktalar ile Deformasyon Alanı Ara Değerlemesi | en_US |
| dc.title.alternative | Deformation field interpolation using rotational landmarks | en_US |
| dc.type | Conference Object | en_US |
| dspace.entity.type | Publication | |
| gdc.author.institutional | Karaçalı, Bilge | |
| gdc.bip.impulseclass | C5 | |
| gdc.bip.influenceclass | C5 | |
| gdc.bip.popularityclass | C5 | |
| gdc.coar.access | open access | |
| gdc.coar.type | text::conference output | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | İzmir Institute of Technology. Electrical and Electronics Engineering | en_US |
| gdc.description.endpage | 4 | |
| gdc.description.publicationcategory | Konferans Öğesi - Ulusal - Kurum Öğretim Elemanı | en_US |
| gdc.description.scopusquality | N/A | |
| gdc.description.startpage | 1 | |
| gdc.description.wosquality | N/A | |
| gdc.identifier.openalex | W2112703423 | |
| gdc.index.type | Scopus | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.impulse | 0.0 | |
| gdc.oaire.influence | 2.635068E-9 | |
| gdc.oaire.isgreen | false | |
| gdc.oaire.popularity | 5.079408E-10 | |
| gdc.oaire.publicfunded | false | |
| gdc.oaire.sciencefields | 03 medical and health sciences | |
| gdc.oaire.sciencefields | 0302 clinical medicine | |
| gdc.oaire.sciencefields | 0202 electrical engineering, electronic engineering, information engineering | |
| gdc.oaire.sciencefields | 02 engineering and technology | |
| gdc.openalex.collaboration | National | |
| gdc.openalex.fwci | 0.0 | |
| gdc.openalex.normalizedpercentile | 0.18 | |
| gdc.opencitations.count | 0 | |
| gdc.plumx.mendeley | 1 | |
| gdc.plumx.scopuscites | 0 | |
| gdc.scopus.citedcount | 0 | |
| relation.isAuthorOfPublication.latestForDiscovery | a081f8c3-cd7b-40d5-a9ca-74707d1b4dc7 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 9af2b05f-28ac-4018-8abe-a4dfe192da5e |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Deformation_field.pdf
- Size:
- 510.67 KB
- Format:
- Adobe Portable Document Format