Development of Single-Use Thin Film Electrodes Based on Zn2sno4 on In2o3:sno2 Substrates With Their Biosensing Applications

Loading...

Date

2022

Authors

Yurttaş, Betül
Özyüzer, Lütfi

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Average

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Dopamine (DA) has a significant impact on the emergence and treatment of certain diseases (e.g., Alzheimer's and Parkinson's diseases). Therefore, monitoring of DA is important, and using biosensors is a favorable option instead of time-consuming and expensive conventional methods. In biosensor manufacturing, thin films have become a rapidly emerging field. In this study, a non-enzymatic electrochemical biosensor based on thin film electrodes is developed for monitoring DA levels. The thin film electrodes (ZTO/ITO) are developed by deposition of Zn2SnO4 (ZTO) on In2O3:SnO2 (ITO) substrates by magnetron sputtering. 3-aminopropyltriethoxysilane (APTES) is used to modify the surface of these electrodes. Physical, optical, and structural properties of the electrodes are determined by applying surface profilometry, UV–VIS–NIR spectrophotometry, X-ray diffraction (XRD), and scanning electron microscopy (SEM) measurements. According to these measurements, it has been observed that the ZTO/ITO combination has a higher optical transmission value than the bare ITO, depending on the deposition time and the oxygen concentration used during ZTO deposition. In addition, the ITO thin film has a crystalline structure, while the ZTO thin film has an amorphous structure and both thin films have a good surface morphology. As electrochemical analysis, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) measurements are performed. As a result of CV and EIS measurements, a remarkable change (63.54%) was observed after applying APTES modification onto the surface of ZTO/ITO electrode, and the ones obtained by DPV showed successful detection of DA by APTES modified ZTO/ITO. In addition, the experiments in the presence of interferences such as ascorbic acid (AA), uric acid (UA), bovine serum albumin (BSA), and fish sperm double-stranded DNA (fsDNA) show that the electrodes can be successfully applied for voltammetric determination of DA. The detection limit of DA was estimated to be 0.013 µM in the range of DA between 0.1 and 1 µM, and sensitivity was calculated and found to be 11.057 μA μg−1 mL cm−2, which means ZTO/ITO electrodes have a good sensitivity.

Description

Keywords

Dopamine detection, Electrochemical biosensor, Magnetron sputtering, Thin film electrode, Chemiluminescence, Uric-Acid, Ascorbic-Acid, Thin film electrode, Dopamine, 5-Hydroxytryptamine, Electrochemical biosensor, Electrochemical Detection, Dopamine detection, Quantum Dots, Gold Nanoparticles, Graphene Oxide, Magnetron sputtering, Sensor

Fields of Science

02 engineering and technology, 0210 nano-technology

Citation

WoS Q

Q2

Scopus Q

Q2
OpenCitations Logo
OpenCitations Citation Count
2

Source

Materials Today Communications

Volume

33

Issue

Start Page

End Page

PlumX Metrics
Citations

CrossRef : 3

Scopus : 4

Captures

Mendeley Readers : 7

SCOPUS™ Citations

4

checked on Apr 27, 2026

Web of Science™ Citations

4

checked on Apr 27, 2026

Page Views

569

checked on Apr 27, 2026

Downloads

67

checked on Apr 27, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.43058688

Sustainable Development Goals

SDG data is not available