Design and Implementation of a Tem Stripline for Emc Testing

Loading...

Date

Authors

Kuştepeli, Alp

Journal Title

Journal ISSN

Volume Title

Open Access Color

BRONZE

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Top 10%
Popularity
Average

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

In this paper, a stripline for radiated field immunity testing of audio/video products is designed, constructed, calibrated, and verified. Since the canonical one is only suitable for testing equipments with height less than 70 cm, there is a need of a new device which is also in compliance with EN 55020 standard for testing new large sets, like 47″ thin-film transistor liquid crystal display (TFT LCD) television sets, in the frequency range of 150 kHz-150 MHz. Increasing the height and width of testing area causes important problems in terms of field uniformity regarding the higher order modes, characteristic impedance, and reflections in addition to the room resonances and field interference sources like corners at the edges of stripline. Comprehensive numerical study is performed to overcome these problems and obtain the optimum design before the construction. Measured data show that the new stripline is in very good agreement with the specifications determined by the standards and therefore it can be used for the electromagnetic compatibility (EMC) testing.

Description

Keywords

EN 55020, EN 61000-4-20, Electromagnetic compatibility, Magnetic susceptibility, Stripline, Magnetic susceptibility, EN 61000-4-20, EN 55020, Stripline, Electromagnetic compatibility

Fields of Science

0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology

Citation

Hilavin, S.,and Kustepeli, A. (2014). Design and implementation of a TEM stripline for EMC testing. IEEE Transactions on Electromagnetic Compatibility, 56(1), 23-27. doi:10.1109/TEMC.2013.2271834

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
8

Volume

56

Issue

1

Start Page

23

End Page

27
PlumX Metrics
Citations

CrossRef : 6

Scopus : 10

Captures

Mendeley Readers : 7

SCOPUS™ Citations

10

checked on May 01, 2026

Web of Science™ Citations

7

checked on May 01, 2026

Page Views

934

checked on May 01, 2026

Downloads

1291

checked on May 01, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.2393814

Sustainable Development Goals

SDG data is not available