Effect of Silicon Nitride Coating Thickness on Silicon Wafer Substrates for Signal Enhancement in Laser-Induced Breakdown Spectroscopic Analysis of Liquids

Loading...

Date

Authors

Yalçın, Şerife Hanım

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

It has been shown by previous studies of our group that the use of nitride-coated silicon wafer surfaces as a sample loading substrate in dried-droplet LIBS analysis provided enhancement in plasma emission signal and better detection limits compared to uncoated or oxide-coated silicon wafer surfaces. To further investigate the effect of coating thickness for enhanced sensitivity in dried nano-droplet analysis of liquids, silicon-wafer substrates of different nitride coating thicknesses; 75, 300, 450, and 1000 nm, were comparatively studied. With 75 nm silicon nitride coating, the thin-film effect due to the anti-reflective behavior of the silicon nitride film is observed, and plasma emission signal is enhanced up to three times compared to 300 nm coated substrates. With coating thicknesses of 450 nm and 1000 nm, on the other hand, thermophysical and mechanical properties of the silicon nitride material, like thermal conductivity and hardness, become more dominant factors, leading to higher emission signals for all the elements studied. With 1000 nm coating thickness, enhancement factors of 4.8, 6.4, and 3.7 were obtained for the elements of Pb, Cu, and Cr, respectively. Optimization of the experimental LIBS parameters was conducted, calibration curves were constructed, and analytical figures of merits were determined. Sub-picogram amounts absolute detection limits; 0.7 pg Pb, 0.6 pg Cr, and 0.4 pg Cu, in 500 nanoliter droplets were obtained from the slopes of the calibration curves. The nitride-coated substrates' analytical performance was tested using certified reference solutions, standard water, and real water samples. The materials and the methodology developed can be used for waste-water monitoring of environmental samples by LIBS.

Description

The authors acknowledge research grant 119F068 from TUBITAK

Keywords

Dried droplet analysis, Thermal conductivity, Silicon nitride, Laser-induced breakdown spectroscopy

Fields of Science

01 natural sciences, 0104 chemical sciences

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
7

Volume

194

Issue

Start Page

End Page

PlumX Metrics
Citations

CrossRef : 12

Scopus : 15

Captures

Mendeley Readers : 10

SCOPUS™ Citations

15

checked on Apr 28, 2026

Web of Science™ Citations

13

checked on Apr 28, 2026

Page Views

6913

checked on Apr 28, 2026

Downloads

113

checked on Apr 28, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
2.25841828

Sustainable Development Goals

SDG data is not available