    Arsenic Removal by Electrocoagulation
    (Wiley, 2022) Gören, Ayşegül Yağmur; Kobya, Mehmet
    Because of the toxic impacts on human health, the arsenic (As) limit value in drinking water was decreased from 50 to 10 ?g l-1 by the relevant authorities (WHO 1993; US EPA 2001). In this case, the problem of As pollution in natural water resources used for drinking water has grown even more and turned into a global crisis. According to reports in many parts of the world, over about 230 million people appear to be affected by high arsenic concentrations in groundwater. In this case, it turned out that there was a great need for cost-effective and environmentally friendly technologies from drinking water sources. One of the emerging water treatment technologies in recent years is electrocoagulation (EC) and it has been seen that it is effective in treating As (>99%) from water and eliminates some of the disadvantages of other conventional treatment processes. EC method includes electro-oxidation of anode electrode materials (iron and aluminum) and in situ production of coagulant agents. From groundwater resources with As content of 5-1000 ?g l-1, As removal efficiencies and operating costs (OCS) of EC technology using iron (Fe) and aluminum (Al) anodes were 85.0-99.9% and 0.0020-1.04 US$ m-3, respectively. Different types (plate, scrap, rod, and ball) of electrodes were used for As removal with the EC process, and it was observed that Fe electrodes or Fe-Al hybrid electrodes performed better in As removal. In addition, it has been determined that arsenate (As(V)) removal is more effective than arsenite (As(III)). A significant quantity of As(III) is oxidized in the EC process, resulting in precipitation, adsorption, and metal-oxy hydroxylic complex reactions. EC process has a lower OC to achieve As removal below the permissible WHO value compared to conventional treatment processes, accomplishing it as a further applicable option for As removal. © 2023 John Wiley & Sons, Inc.
  • Article
    Citation - WoS: 12
    Citation - Scopus: 14
    Identifying Geogenic and Anthropogenic Aluminum Pollution on Different Spatial Distributions and Removal of Natural Waters and Soil in Çanakkale, Turkey
    (Amer Chemical Soc, 2023) Hızlı, Sezin; Koraoğlu, Aybike Gül; Gören, Ayşegül Yağmur; Kobya, Mehmet
    The Canakkale-Kirazli region (Turkey) is enriched with minerals, especially aluminum (Al), which dangerously get transported into aquatic media due to several mining and geological activities in recent years. In this study, Al and other potentially toxic metals (PTMs) including B, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Si, and Zn, in both water and soil samples, were measured for quality determination. Selected metals were also analyzed by the enrichment factor (EF), the geoaccumulation index (I-geo), the contamination factor (CF), and the pollution load index (PLI) to evaluate both water and soil pollution geogenically or anthropogenically. Also, the metals were clustered to support the pollution source with Pearson's correlation, principal component analysis (PCA), and hierarchical cluster analysis (HCA). Forty-five natural water samples and 12 soil samples were collected spatially. To perform pollution assessment, two fundamental treatment processes to remove Al pollution from the sample including the highest Al concentration (38.38 mg/L) in water were applied: (1) precipitation with pH adjustment and (2) removal with ion exchange. The pH values of water samples were changed in the range of 3-9 to test the dissolution of Al. The results demonstrated that the study area was mostly under the influence of geogenic aluminum pollution.
  • Article
    Citation - WoS: 8
    Citation - Scopus: 8
    Removal of Arsenic in Groundwater From Western Anatolia, Turkey Using an Electrocoagulation Reactor With Different Types of Iron Anodes
    (Elsevier, 2022) Kobya, Mehmet; Dolaz, Mustafa; Özaydın Şenol, Burcu; Gören, Ayşegül Yağmur
    Electrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 μg L−1, GW-2: 1132.1 μg L−1, and GW-3: 52, 000 μg L−1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 μg L−1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As removal efficiency, EC time, and operating cost were >99.9%, 180 min and 0.406 $ m−3 for ball anodes, >99.9%, 100 min and 0.0813 $ m−3 for plate anodes, >99.9%, 80 min and 0.0815 $ m−3 for scrap anodes for GW-3, respectively. It was observed that as the As concentration in the GW increased, the EC time and operating cost increased. Overall, it was concluded that Fe scrap anodes are more advantageous than other types of anodes in terms of operating cost in EC reactor for As removal.
  • Article
    Citation - WoS: 9
    Citation - Scopus: 9
    How Does Arsenic Speciation (arsenite and Arsenate) in Groundwater Affect the Performance of an Aerated Electrocoagulation Reactor and Human Health Risk?
    (Elsevier, 2022) Gören, Ayşegül Yağmur; Kobya, Mehmet; Khataee, Alireza
    Arsenic (As) occurrence in water resources has become one of the most critical environmental problems worldwide. The detrimental health impacts on humans have been reported due to the consumption of As-contaminated groundwater resources. Consumption of As-containing water over the long term can cause arsenicosis and chronic effects on human health due to its toxicity. Several treatment processes are available for As removals such as coagulation, ion exchange, adsorption, and membrane technologies but they have various major drawbacks. In the present work, therefore, an aerated electrocoagulation (EC) system with aluminum anodes was operated for simultaneous arsenate (As(V)) and arsenite (As(III)) removal to overcome the disadvantages of other processes such as, sludge formation, difficulties in operation, high operating costs, high energy consumption, and the requirement of pre-treatment process and to enhance the conventional EC process. The combined effects of the applied current (0.075–0.3 A), aeration rate (0–6 L/min), pH (6.5–8.5), and As speciation (As(V)-As(III)) were studied on As removal efficiency. The findings revealed that As removal mostly depended on the airflow rate and the applied current in the EC system. The highest As removal efficiency (99.1%) was obtained at an airflow rate of 6 L/min, a pH of 6.5, an initial As (V) concentration of 200 μg/L, and a current of 0.3 A, with an energy consumption of 2.85 kWh/m3 and an operating cost of 0.66 $/m3. The human health risk assessment of treated water was also examined to understand the performance of the EC system. At most of the experimental runs, the chronic toxic risk (CTR) and carcinogenic risk (CR) of As were within the permissible limits except for an airflow rate of 0–2 L/min, an initial pH of 8.5, and a current of 0.075–0.15 A for high initial As (III) concentrations. Overall, the As removal performance and groundwater risk assessment show that the EC process is a promising option for industrial applications.
  • Article
    Citation - WoS: 1
    Arsenate Removal From Groundwater by Air-Injected Ec With Al Ball Anodes: Effects of Operational Parameters
    (Pamukkale Üniversitesi, 2020) Gören, Ayşegül Yağmur; Öncel, Mehmet Salim; Kobya, Mehmet
    Treatment of arsenate from groundwater by electrocoagulation (EC) reactor with air supply unit using Al ball electrodes were studied in this paper. Influence of some operating variables, for instance, applied current (0.075-0.3 A), initial pH (5.5-8.5), air flow rate (0-6 L/min), size of Al ball electrodes (5-10 mm), and height of electrode in EC reactor (2-8 cm) on the As(V) removal efficiency were evaluated. The As (V) removal efficiency increased with the increment of applied current, air flow, electrode altitude in EC reactor, and EC time while its removal efficiency decreased with the increment of size of Al ball electrodes. The maximum As(V) removal percentage, minimum operating cost and energy consumption were found as 98.68 %, 0.609 $/$m^3$ and 3.7694 kWh/$m^3$ at pH of 7.5, current density of 0.30 A, size of Al balls of 7.5 mm, height of electrode in EC of 5 c†m, and air flow rate of 6 L/min, respectively
  • Article
    Citation - WoS: 47
    Citation - Scopus: 57
    Arsenic Removal From Groundwater Using an Aerated Electrocoagulation Reactor With 3d Al Electrodes in the Presence of Anions
    (Elsevier, 2021) Gören, Ayşegül Yağmur; Kobya, Mehmet
    Co-occurrence of arsenic and anions in groundwater causes a severe health problems and combine effects of these pollutants significantly affect performance of treatment process. Thus, this study has been conducted to examine the combine effects of anions on arsenic removal using aerated electrocoagulation (EC) reactor with 3D Al electrodes in groundwater. A 3-level, six factors Box-Behnken experimental design (BBD) was applied to investigate the individual and combine effect of anions and operating time: phosphate (x1: 1–10 mg L?1), silica (x2: 20–80 mg L?1), bicarbonate (x3: 130–670 mg L?1), fluoride (x4: 2–10 mg L?1), boron (x5: 5–10 mg L?1), and operating time (x6: 8–22 min) on desired responses. The specified responses were effluent arsenic concentration (Cf,As), removal efficiency of arsenic (Re), consumptions of energy and electrode (ENC and ELC), operational cost (OC), and adsorption capacity (qe). The optimum operating parameters predicted using BBD were found to be x1: 1.0 mg L?1, x2: 26.0 mg L?1, x3: 651.5 mg L?1, x4: 2.0 mg L?1, x5: 9.9 mg L?1, and x6: 10.5 min considering highest removal efficiency of arsenic and lowest operational cost. Under these operating conditions, the experimental values of Cf,As, Re, ENC, ELC, OC, and qe were found to be 2.82 ?g L?1, 98.6%, 0.411 kWh m?3, 0.0124 kg m?3, 0.098 $ m?3, and 17.65 ?g As (mg Al)?1, respectively. Furthermore, mathematical modelling was conducted using quadratic regression model and response surface analysis was performed to understand the relationship between independent parameters and responses. © 2020 Elsevier Ltd
  • Article
    Citation - WoS: 10
    Citation - Scopus: 12
    Removal of Arsenate by Electrocoagulation Reactor Using Aluminum Ball Anode Electrodes
    (IWA Publishing, 2018) Gören, Ayşegül Yağmur; Öncel, Mehmet Salim; Demirbaş, Erhan; Şık, Emrah; Kobya, Mehmet
    The aim of this research was to remove arsenate (As(V)) from groundwater using an air-injected electrocoagulation (EC) reactor with aluminum (Al) ball anodes. The effects of seven operating variables - initial pH, applied current (i), operating time (t(EC)), initial As(V) concentration (C-o), Al ball anode diameter (d(p)), reactor column height (h), and airflow rate (Q(air)) were investigated with a Box-Behnken statistical experimental design. ANOVA results from the quadratic model equations indicated that the model fitted very well with the experimental data for the responses, which were removal efficiency, operating cost (OC), As(V) adsorption capacity, and effluent concentration (R-2 >= 0.87). The most effective parameters were applied current, operating time, and anode height for As(V) removal efficiency in the EC reactor, while initial pH, Al anode diameter, and air flow rate had limited effect on removal. The model predicted a residual As(V) concentration below 10 mu g/L under the optimum operating conditions (pH 7.03, 0.29 A, 10.5 min, d(p) 7.5 mm, 613.4 mu g/L, h 5.1 cm, and Q(air) 6.4 L/min). The maximum As(V) removal efficiency and minimum OC in the EC process were almost 99% and 0.442 $/m(3), respectively.
  • Article
    Citation - WoS: 26
    Citation - Scopus: 34
    Arsenite Removal From Groundwater in a Batch Electrocoagulation Process: Optimization Through Response Surface Methodology
    (Taylor & Francis, 2019) Şık, Emrah; Gören, Ayşegül Yağmur; Demirbaş, Erhan; Kobya, Mehmet; Öncel, Mehmet Salim
    In this study, influences of seven process variables such as initial pH (pH(i)), applied current (i), operating time (t(EC)), initial As(III) concentration (C-o), diameter of Fe ball anode (d(p)), column height in the electrocoagulation (EC) reactor (h) and airflow rate (Q(air)) for removal of As(III) from groundwater by a new air-fed fixed-bed EC reactor were evaluated with a response surface methodology (RSM). The proposed quadratic model fitted very well with the experimental data for the responses. The removal efficiencies and operating costs were determined to be 99% and 0.01 $/m(3) at the optimum operating conditions (a pH(i) of 8.5, 0.05 A, 4.94 min, d(p) of 9.24 mm, h of 7.49 cm, Q(air) of 9.98 L/min for 50 mu g/L). This study clearly showed that the RSM in the EC process was a very suitable method to optimize the operating conditions at the target value of effluent As(III) concentration (10 mu g/L) while keeping the operating cost to minimal and maximize the removal efficiency.
  • Article
    Citation - WoS: 4
    Citation - Scopus: 5
    Combined Influence of Some Cations on Arsenic Removal by an Air-Injection Ec Reactor Using Aluminum Ball Electrodes
    (Desalination Publications, 2020) Gören, Ayşegül Yağmur; Kobya, Mehmet; Şık, Emrah; Demirbaş, Erhan; Öncel, Mehmet Salim
    Combined effects of some cations such as calcium (Ca2+), iron (Fe2+), manganese (Mn2+), and magnesium (Mg2+) and operating time on the removal of arsenic by air-injected electrocoagulation (EC) reactor with aluminum (Al) ball electrodes were investigated. The operating conditions were optimized with the Box-Behnken design of response surface methodology (RSM). The response variables were selected from the program as removal efficiency, residual arsenic concentration, energy consumption and operating cost (OC) in the EC process. A total of 46 experimental run was performed. The removal efficiency of arsenic increased with an increase in iron concentration (0.5-4.5 mg/L). The rest of the cations showed no noticeable effect on arsenic removal efficiency. The maximum arsenic removal efficiency and minimum OC at the optimum operating conditions (C-Ca: 305 mg/L, C-Mg: 42 mg/L, C-Fe: 3.3 mg/L, C-Mn: 2.34 mg/L, initial pH of 7.5 applied current of 0.15 A, Al ball size of 7.5 mm, 5.0 cm of Al ball anodes height in the EC reactor, air-fed rate of 6.0 L/min and t(EC): 16.83 min) in the EC process were 99.9% and 0.0332 $/m(3) for initial arsenic concentration of 200 mu g/L, respectively. The removal mechanism of As(III) by EC seems to be oxidation of As(III) to As(V) and subsequent removal by adsorption/complexation with aluminum hydroxides generated in the process. The results showed that the air-injected EC reactor can be used effectively for arsenic and hardness removal simultaneously from real groundwater sources.
  • Article
    Citation - WoS: 37
    Citation - Scopus: 40
    Arsenite Removal From Groundwater by Aerated Electrocoagulation Reactor With Al Ball Electrodes: Human Health Risk Assessment
    (Elsevier, 2020) Gören, Ayşegül Yağmur; Kobya, Mehmet; Öncel, Mehmet Salim
    The application of conventional electrocoagulation (EC) process for removal of As(III) from groundwater suffers from the need of external oxidation agent for oxidation of As(III) to As(V). To tackle this limitation, an aerated EC reactor for the removal of As(III) from groundwater was evaluated in this study. The effect of initial pH(i), air flow rate, applied current, and electrode height in the EC reactor was examined. The experimental results showed that removal of arsenic mostly dependent on the applied current, electrode height in EC reactor, and air flow rate. The As(III) removal efficiency (99.2%) was maximum at pH(i) of 7.5, air flow rate of 6 L min(-1), applied current of 0.30 A, and electrode height in EC reactor of 5 cm, with an total operating cost of 0.583 $ m(-3). Furthermore, the carcinogenic risk (CR) and non-carcinogenic risk of arsenic (As) was in the range of tolerable limits at all operating conditions except applied current of 0.075 A at the end of the aerated EC process to remove As from groundwater. The present EC reactor process is able to remove As(III) from groundwater to below 10 mu g L-1, which is maximum contaminant level of arsenic in drinking water according to the World Health Organization (WHO). (C) 2020 Elsevier Ltd. All rights reserved.