Environmental Engineering / Çevre Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4321

Browse

Search Results

Now showing 1 - 7 of 7
  • Article
    Citation - WoS: 8
    Citation - Scopus: 8
    Removal of Arsenic in Groundwater From Western Anatolia, Turkey Using an Electrocoagulation Reactor With Different Types of Iron Anodes
    (Elsevier, 2022) Kobya, Mehmet; Dolaz, Mustafa; Özaydın Şenol, Burcu; Gören, Ayşegül Yağmur
    Electrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 μg L−1, GW-2: 1132.1 μg L−1, and GW-3: 52, 000 μg L−1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 μg L−1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As removal efficiency, EC time, and operating cost were >99.9%, 180 min and 0.406 $ m−3 for ball anodes, >99.9%, 100 min and 0.0813 $ m−3 for plate anodes, >99.9%, 80 min and 0.0815 $ m−3 for scrap anodes for GW-3, respectively. It was observed that as the As concentration in the GW increased, the EC time and operating cost increased. Overall, it was concluded that Fe scrap anodes are more advantageous than other types of anodes in terms of operating cost in EC reactor for As removal.
  • Article
    Citation - WoS: 9
    Citation - Scopus: 9
    How Does Arsenic Speciation (arsenite and Arsenate) in Groundwater Affect the Performance of an Aerated Electrocoagulation Reactor and Human Health Risk?
    (Elsevier, 2022) Gören, Ayşegül Yağmur; Kobya, Mehmet; Khataee, Alireza
    Arsenic (As) occurrence in water resources has become one of the most critical environmental problems worldwide. The detrimental health impacts on humans have been reported due to the consumption of As-contaminated groundwater resources. Consumption of As-containing water over the long term can cause arsenicosis and chronic effects on human health due to its toxicity. Several treatment processes are available for As removals such as coagulation, ion exchange, adsorption, and membrane technologies but they have various major drawbacks. In the present work, therefore, an aerated electrocoagulation (EC) system with aluminum anodes was operated for simultaneous arsenate (As(V)) and arsenite (As(III)) removal to overcome the disadvantages of other processes such as, sludge formation, difficulties in operation, high operating costs, high energy consumption, and the requirement of pre-treatment process and to enhance the conventional EC process. The combined effects of the applied current (0.075–0.3 A), aeration rate (0–6 L/min), pH (6.5–8.5), and As speciation (As(V)-As(III)) were studied on As removal efficiency. The findings revealed that As removal mostly depended on the airflow rate and the applied current in the EC system. The highest As removal efficiency (99.1%) was obtained at an airflow rate of 6 L/min, a pH of 6.5, an initial As (V) concentration of 200 μg/L, and a current of 0.3 A, with an energy consumption of 2.85 kWh/m3 and an operating cost of 0.66 $/m3. The human health risk assessment of treated water was also examined to understand the performance of the EC system. At most of the experimental runs, the chronic toxic risk (CTR) and carcinogenic risk (CR) of As were within the permissible limits except for an airflow rate of 0–2 L/min, an initial pH of 8.5, and a current of 0.075–0.15 A for high initial As (III) concentrations. Overall, the As removal performance and groundwater risk assessment show that the EC process is a promising option for industrial applications.
  • Article
    Citation - WoS: 47
    Citation - Scopus: 57
    Arsenic Removal From Groundwater Using an Aerated Electrocoagulation Reactor With 3d Al Electrodes in the Presence of Anions
    (Elsevier, 2021) Gören, Ayşegül Yağmur; Kobya, Mehmet
    Co-occurrence of arsenic and anions in groundwater causes a severe health problems and combine effects of these pollutants significantly affect performance of treatment process. Thus, this study has been conducted to examine the combine effects of anions on arsenic removal using aerated electrocoagulation (EC) reactor with 3D Al electrodes in groundwater. A 3-level, six factors Box-Behnken experimental design (BBD) was applied to investigate the individual and combine effect of anions and operating time: phosphate (x1: 1–10 mg L?1), silica (x2: 20–80 mg L?1), bicarbonate (x3: 130–670 mg L?1), fluoride (x4: 2–10 mg L?1), boron (x5: 5–10 mg L?1), and operating time (x6: 8–22 min) on desired responses. The specified responses were effluent arsenic concentration (Cf,As), removal efficiency of arsenic (Re), consumptions of energy and electrode (ENC and ELC), operational cost (OC), and adsorption capacity (qe). The optimum operating parameters predicted using BBD were found to be x1: 1.0 mg L?1, x2: 26.0 mg L?1, x3: 651.5 mg L?1, x4: 2.0 mg L?1, x5: 9.9 mg L?1, and x6: 10.5 min considering highest removal efficiency of arsenic and lowest operational cost. Under these operating conditions, the experimental values of Cf,As, Re, ENC, ELC, OC, and qe were found to be 2.82 ?g L?1, 98.6%, 0.411 kWh m?3, 0.0124 kg m?3, 0.098 $ m?3, and 17.65 ?g As (mg Al)?1, respectively. Furthermore, mathematical modelling was conducted using quadratic regression model and response surface analysis was performed to understand the relationship between independent parameters and responses. © 2020 Elsevier Ltd
  • Article
    Citation - WoS: 26
    Citation - Scopus: 34
    Arsenite Removal From Groundwater in a Batch Electrocoagulation Process: Optimization Through Response Surface Methodology
    (Taylor & Francis, 2019) Şık, Emrah; Gören, Ayşegül Yağmur; Demirbaş, Erhan; Kobya, Mehmet; Öncel, Mehmet Salim
    In this study, influences of seven process variables such as initial pH (pH(i)), applied current (i), operating time (t(EC)), initial As(III) concentration (C-o), diameter of Fe ball anode (d(p)), column height in the electrocoagulation (EC) reactor (h) and airflow rate (Q(air)) for removal of As(III) from groundwater by a new air-fed fixed-bed EC reactor were evaluated with a response surface methodology (RSM). The proposed quadratic model fitted very well with the experimental data for the responses. The removal efficiencies and operating costs were determined to be 99% and 0.01 $/m(3) at the optimum operating conditions (a pH(i) of 8.5, 0.05 A, 4.94 min, d(p) of 9.24 mm, h of 7.49 cm, Q(air) of 9.98 L/min for 50 mu g/L). This study clearly showed that the RSM in the EC process was a very suitable method to optimize the operating conditions at the target value of effluent As(III) concentration (10 mu g/L) while keeping the operating cost to minimal and maximize the removal efficiency.
  • Article
    Citation - WoS: 3
    Citation - Scopus: 6
    Optimization of Some Cations for Removal of Arsenic From Groundwater by Electrocoagulation Process
    (Gheorghe Asachi Technical University of Iasi, 2018) Kobya, Mehmet; Şık, Emrah; Demirbaş, Erhan; Gören, Ayşegül Yağmur; Öncel, Mehmet Salim
    This study dealt with investigation of arsenic removal from groundwater using electrocoagulation (EC) method in a batch mode by the Box-Behnken experimental design method. Effects of some cations like Ca, Fe, Mg, Mn and operating time on the removal were explored by an air injected EC reactor. The combined effects of these variables were analyzed by the quadratic model for predicting the highest removal efficiency of arsenic from groundwater. The arsenic removal efficiency was found to be dependent on increase with operating time and concentrations of Ca, Mg, Fe and lower concentration of Mn. When operating variables were considered as minimum operating cost and maximum removal efficiency, the optimum operating parameters were determined to be 132 mg/L of CCa, 55 mg/L of CMg, 4.5 mg /L of CFe, 4.5 mg/L of CMn and operating time of 3 min to meet the target concentration of <10 μg/L. Values of removal efficiency and operating cost at the optimum conditions were 95.1% and 0.041 $/m3.
  • Conference Object
    Groundwater Pollution by Nitrate From Agricultural Fertilizers: the Case of Menemen Basin (aegean Region, Turkey)
    (İZSU, 2017) Gören, Ayşegül Yağmur; Genişoğlu, Mesut; Balcı, Esin; Ökten, Hatice Eser; Baba, Alper
    Groundwater is an essential drinking water source in Menemen sub­basin of İzmir city, Turkey. The aim of this study was to investigate the groundwater contamination by nitrates of agricultural lands. For this purpose, we evaluated variations of groundwater pH, redox potential, electrical conductivity (EC), major anions (NO3, Cl, SO4, HCO3 and CO3) and cations (Na, K, Ca and Mg). A statistical correlation procedure and piper diagram for hydrogeochemistry of groundwater were also applied. Nitrate levels were found to be higher around agricultural areas. Also EC values and Cl­ were measured to be higher as proximity to coastal areas increased, indicating seawater intrusion. Agricultural activities and excessive freshwater withdrawal were shown to impair groundwater quality and quantity at Menemen sub­basin.
  • Article
    Citation - WoS: 28
    Citation - Scopus: 29
    Arsenite and Arsenate Removals From Groundwater by Electrocoagulation Using Iron Ball Anodes: Influence of Operating Parameters
    (Elsevier Ltd., 2017) Şık, E.; Demirbaş, Erhan; Gören, Ayşegül Yağmur; Öncel, Mehmet Salim; Kobya, Mehmet
    Removals of arsenite (As(III)) and arsenate (As(V)) from groundwater by a cylindrical packed-bed electrocoagulation (EC) reactor using Fe ball anodes were investigated in this study. Effects of some operating parameters such as initial pH (pHi of 6.5–8.5), applied current (i of 0.075–0.30 A), initial concentration (Co of 30–200 μg/L), diameter of iron ball (dp of 5.0–10.0 mm), height of anode balls in the reactor (h of 2–8 cm) and airflow rate (Qair of 0.0–6.0 L/min) on the removal efficiency of arsenic were evaluated. The removal efficiency of arsenic decreased with increase in concentrations of arsenic from 30 to 200 μg/L while its removal efficiency increased with increase in operating time, applied current, height of anode in the reactor, and airflow rate. The optimum operating conditions for effective As(III) and As(V) removals to meet the permissible level of arsenic effluent concentration of <10 μg/L were determined as 0.3 A, 14 min of EC time for As(III) and 12 min for As(V), a pHi of 7.5, Co of 200 μg/L, dp of 7.5 mm, h of 7.5 cm and Qair of 6 L/min, respectively. Arsenic removal efficiency, energy and electrode consumptions, operating cost, charge loading and arsenic removed capacity per amount of electrochemically generated Fe at the optimum conditions were also calculated as 96.0%, 1.442 kWh/m3, 0.0752 kg/m3, 0.612 $/m3, 252 C and 2.55 μg/mg Fe (0.762 μg/C) for As(III) removal and 95.8%, 1.386 kWh/m3, 0.0628 kg/m3, 0.546 $/m3, 216 C and 3.05 μg/mg Fe (0.887 μg/C) for As(V) removal, respectively.