Environmental Engineering / Çevre Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4321

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 9
    Citation - Scopus: 9
    How Does Arsenic Speciation (arsenite and Arsenate) in Groundwater Affect the Performance of an Aerated Electrocoagulation Reactor and Human Health Risk?
    (Elsevier, 2022) Gören, Ayşegül Yağmur; Kobya, Mehmet; Khataee, Alireza
    Arsenic (As) occurrence in water resources has become one of the most critical environmental problems worldwide. The detrimental health impacts on humans have been reported due to the consumption of As-contaminated groundwater resources. Consumption of As-containing water over the long term can cause arsenicosis and chronic effects on human health due to its toxicity. Several treatment processes are available for As removals such as coagulation, ion exchange, adsorption, and membrane technologies but they have various major drawbacks. In the present work, therefore, an aerated electrocoagulation (EC) system with aluminum anodes was operated for simultaneous arsenate (As(V)) and arsenite (As(III)) removal to overcome the disadvantages of other processes such as, sludge formation, difficulties in operation, high operating costs, high energy consumption, and the requirement of pre-treatment process and to enhance the conventional EC process. The combined effects of the applied current (0.075–0.3 A), aeration rate (0–6 L/min), pH (6.5–8.5), and As speciation (As(V)-As(III)) were studied on As removal efficiency. The findings revealed that As removal mostly depended on the airflow rate and the applied current in the EC system. The highest As removal efficiency (99.1%) was obtained at an airflow rate of 6 L/min, a pH of 6.5, an initial As (V) concentration of 200 μg/L, and a current of 0.3 A, with an energy consumption of 2.85 kWh/m3 and an operating cost of 0.66 $/m3. The human health risk assessment of treated water was also examined to understand the performance of the EC system. At most of the experimental runs, the chronic toxic risk (CTR) and carcinogenic risk (CR) of As were within the permissible limits except for an airflow rate of 0–2 L/min, an initial pH of 8.5, and a current of 0.075–0.15 A for high initial As (III) concentrations. Overall, the As removal performance and groundwater risk assessment show that the EC process is a promising option for industrial applications.
  • Article
    Citation - WoS: 37
    Citation - Scopus: 40
    Arsenite Removal From Groundwater by Aerated Electrocoagulation Reactor With Al Ball Electrodes: Human Health Risk Assessment
    (Elsevier, 2020) Gören, Ayşegül Yağmur; Kobya, Mehmet; Öncel, Mehmet Salim
    The application of conventional electrocoagulation (EC) process for removal of As(III) from groundwater suffers from the need of external oxidation agent for oxidation of As(III) to As(V). To tackle this limitation, an aerated EC reactor for the removal of As(III) from groundwater was evaluated in this study. The effect of initial pH(i), air flow rate, applied current, and electrode height in the EC reactor was examined. The experimental results showed that removal of arsenic mostly dependent on the applied current, electrode height in EC reactor, and air flow rate. The As(III) removal efficiency (99.2%) was maximum at pH(i) of 7.5, air flow rate of 6 L min(-1), applied current of 0.30 A, and electrode height in EC reactor of 5 cm, with an total operating cost of 0.583 $ m(-3). Furthermore, the carcinogenic risk (CR) and non-carcinogenic risk of arsenic (As) was in the range of tolerable limits at all operating conditions except applied current of 0.075 A at the end of the aerated EC process to remove As from groundwater. The present EC reactor process is able to remove As(III) from groundwater to below 10 mu g L-1, which is maximum contaminant level of arsenic in drinking water according to the World Health Organization (WHO). (C) 2020 Elsevier Ltd. All rights reserved.