Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
3 results
Search Results
Now showing 1 - 3 of 3
Book Part Citation - Scopus: 11Thermodynamic Performance Evaluation of a Geothermal Drying System(Springer Verlag, 2014) Helvacı, Hüseyin Utku; Gökçen Akkurt, GüldenRenewable energy sources such as geothermal energy can be used in drying processes as a heat source due to the high energy costs of fossil fuels. In this study, geothermal cabinet type dryer was constructed and situated in Balcova-Narlidere Geothermal Field, Turkey where the clean city water of district heating system is used as an energy source for the dryer. The dryer was tested on site for drying of olive leaves and energy and exergy analyses of the drying process conducted under two cases: Case 1. Exhaust air was rejected to the environment. Case 2. A portion of exhaust air was re-circulated. Energy Utilization Ratio (EUR) was determined as 7.96 for Case 1 and 50.36 for Case 2. The highest rate of exergy destruction occurred in the fan, followed by heat exchanger and the dryer, accounting for 0.2913, 0.05663 and 0.0115 kW, respectively. Exergetic efficiency of the drying chamber was calculated as 89.66 %. Re-circulating the exhaust air decreased the exergy value at the outlet of the dryer from 0.1013 to 0.08104 kW, indicating that re-using the air increases the performance of the dyer.Article Citation - WoS: 25Citation - Scopus: 25Economical Assessment of Different Hvac Systems for an Operating Room: Case Study for Different Turkish Climate Regions(Elsevier Ltd., 2011) Özyoğurtçu, Gamze; Mobedi, Moghtada; Özerdem, BarışIn this study, the annual energy consumptions of four different heating, ventilation and air conditioning (HVAC) systems serving to operation rooms (ORs) located at five different cities (Izmir, Antalya, Istanbul, Ankara and, Erzurum) in Turkey are analyzed. The study is performed for four different HVAC systems: (a) 100% fresh air system (System I), (b) 100% fresh air with half air volume rate at night period (System II), (c) 100% fresh air with half air volume rate at night period and heat recovery unit (System III), (d) 50% fresh air with half air volume rate at night period and with heat recovery and mixing units (System IV). Life cycle cost (LCC) for 20 years life span is calculated for the considered systems. It is found that System IV considerably reduces energy consumption and it is economically proper for the considered cities. The rate of energy consumption and LCC reductions are greater for the cities with extreme climate condition having relatively low specific humidity ratio. Using System IV instead of System I reduces OR energy consumption by 74% for the city of Erzurum which has a cold and dry climate.Article Citation - WoS: 30Citation - Scopus: 32Performance investigation of the drying of parsley in a tray dryer system(Inderscience Enterprises Ltd., 2010) Hancıoğlu, Ebru; Hepbaşlı, Arif; İçier, Filiz; Erbay, Zafer; Çolak, NeslihanThe performance of a tray dryer system for the parsley drying process was assessed using energy and exergy analysis methods in this study. The drying temperature ranged from 40°C to 60°C, while the drying air velocity varied from 0.5 m/s to 1.5 m/s. The higher temperature and lower velocity led to higher exergy and energy efficiencies. The exergy efficiency value for the overall system on a product/fuel basis was found to be 3.62%. The values for Specific Moisture Extraction Rate (SMER) and Specific Moisture Exergetic index (SMExR) were obtained to be 0.08 and 2.47 kg/kWh, respectively. Copyright © 2010 Inderscience Enterprises Ltd.
