Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 4 of 4
  • Article
    Citation - WoS: 31
    Citation - Scopus: 33
    Energy and Exergy Analysis of a Pv-T Integrated Ethanol Pem Electrolyzer
    (Pergamon-Elsevier Science Ltd, 2021) Çağlar, Başar; Araz, Mustafa; Özcan, Hüseyin Günhan; Çalışan, Atalay; Hepbaşlı, Arif
    A photovoltaic-thermal (PV-T) integrated ethanol proton exchange membrane electrolyzer (PEME) was proposed as a low-energy consuming energy storage option for renewable-sourced electricity as well as a way for simultaneous chemical production in this study. Energy and exergy analyses were applied to each component of the system (e.g., pumps, heat exchanger, PV-T, PEME, and separation unit (SPU)) and the whole system to assess the system performance. The mathematical modelling of the whole system along with its main components except for the SPU was done using the Engineering Equation Solver (EES) software package while the SPU was modelled through the ASPEN Plus. A detailed modelling of the PEME was also included. The effects of the PV-T and PEME parameters on energy and exergy efficiencies of the system were evaluated while the improvement potentials and scale up options were discussed. Energy and exergy efficiencies of the proposed system at the optimum operation of the PEME and under average climatic conditions in the city of Izmir, Turkey were determined to be 27.8% and 3.1%, respectively. Energy and exergy efficiencies of the system were mainly regulated by the PV-T and PEME, whose energy and exergy efficiencies were 40.6%, 56.6% and 13.8%, 14.1%, respectively. Effective PEME parameters for energy and exergy efficiencies of the system were membrane conductivity, membrane thickness, anode catalyst and the operation temperature of the PEME. By changing the PV-T and PEME parameters and by scale-up, energy and exergy efficiencies of the system could be improved.
  • Book Part
    Citation - Scopus: 11
    Thermodynamic Performance Evaluation of a Geothermal Drying System
    (Springer Verlag, 2014) Helvacı, Hüseyin Utku; Gökçen Akkurt, Gülden
    Renewable energy sources such as geothermal energy can be used in drying processes as a heat source due to the high energy costs of fossil fuels. In this study, geothermal cabinet type dryer was constructed and situated in Balcova-Narlidere Geothermal Field, Turkey where the clean city water of district heating system is used as an energy source for the dryer. The dryer was tested on site for drying of olive leaves and energy and exergy analyses of the drying process conducted under two cases: Case 1. Exhaust air was rejected to the environment. Case 2. A portion of exhaust air was re-circulated. Energy Utilization Ratio (EUR) was determined as 7.96 for Case 1 and 50.36 for Case 2. The highest rate of exergy destruction occurred in the fan, followed by heat exchanger and the dryer, accounting for 0.2913, 0.05663 and 0.0115 kW, respectively. Exergetic efficiency of the drying chamber was calculated as 89.66 %. Re-circulating the exhaust air decreased the exergy value at the outlet of the dryer from 0.1013 to 0.08104 kW, indicating that re-using the air increases the performance of the dyer.
  • Article
    Citation - WoS: 25
    Citation - Scopus: 25
    Economical Assessment of Different Hvac Systems for an Operating Room: Case Study for Different Turkish Climate Regions
    (Elsevier Ltd., 2011) Özyoğurtçu, Gamze; Mobedi, Moghtada; Özerdem, Barış
    In this study, the annual energy consumptions of four different heating, ventilation and air conditioning (HVAC) systems serving to operation rooms (ORs) located at five different cities (Izmir, Antalya, Istanbul, Ankara and, Erzurum) in Turkey are analyzed. The study is performed for four different HVAC systems: (a) 100% fresh air system (System I), (b) 100% fresh air with half air volume rate at night period (System II), (c) 100% fresh air with half air volume rate at night period and heat recovery unit (System III), (d) 50% fresh air with half air volume rate at night period and with heat recovery and mixing units (System IV). Life cycle cost (LCC) for 20 years life span is calculated for the considered systems. It is found that System IV considerably reduces energy consumption and it is economically proper for the considered cities. The rate of energy consumption and LCC reductions are greater for the cities with extreme climate condition having relatively low specific humidity ratio. Using System IV instead of System I reduces OR energy consumption by 74% for the city of Erzurum which has a cold and dry climate.
  • Article
    Citation - WoS: 30
    Citation - Scopus: 32
    Performance investigation of the drying of parsley in a tray dryer system
    (Inderscience Enterprises Ltd., 2010) Hancıoğlu, Ebru; Hepbaşlı, Arif; İçier, Filiz; Erbay, Zafer; Çolak, Neslihan
    The performance of a tray dryer system for the parsley drying process was assessed using energy and exergy analysis methods in this study. The drying temperature ranged from 40°C to 60°C, while the drying air velocity varied from 0.5 m/s to 1.5 m/s. The higher temperature and lower velocity led to higher exergy and energy efficiencies. The exergy efficiency value for the overall system on a product/fuel basis was found to be 3.62%. The values for Specific Moisture Extraction Rate (SMER) and Specific Moisture Exergetic index (SMExR) were obtained to be 0.08 and 2.47 kg/kWh, respectively. Copyright © 2010 Inderscience Enterprises Ltd.